305 research outputs found

    Creating and Certifying the Professional Mediator -- Education and Credentialing

    Get PDF
    Existing and pending law school mediation programs, post-graduate mediator training programs, mentorship programs, credentialing movements, and continuing mediation education were examined by a panel and speakers directly involved in those fields. Are we effectively training new mediators in law schools and post-graduate programs? Should we, and how can we, credential mediators? Do good mediators need to be re-trained? How would continuing mediation educational requirements be implemented

    Creating and Certifying the Professional Mediator -- Education and Credentialing

    Get PDF
    Existing and pending law school mediation programs, post-graduate mediator training programs, mentorship programs, credentialing movements, and continuing mediation education were examined by a panel and speakers directly involved in those fields. Are we effectively training new mediators in law schools and post-graduate programs? Should we, and how can we, credential mediators? Do good mediators need to be re-trained? How would continuing mediation educational requirements be implemented

    Cyberknife Stereotactic Body Radiation Therapy for Nonresectable Tumors of the Liver: Preliminary Results

    Get PDF
    Purpose. Stereotactic body radiation therapy (SBRT) has emerged as a treatment option for local tumor control of primary and secondary malignancies of the liver. We report on our updated experience with SBRT in patients with non-resectable tumors of the liver. Methods. Our first 17 consecutive patients (mean age 58.1 years) receiving SBRT for HCC (n = 6), IHC (n = 3), and LM (n = 8) are presented. Mean radiation dose was 34Gy delivered over 1–3 fractions. Results. Treated patients had a mean decrease in maximum pretreatment tumor diameter from 6.9 ± 4.6 cm to 5.0 ± 2.1 cm at three months after treatment (P < .05). The mean total tumor volume reduction was 44% at six months (P < .05). 82% of all patients (14/17) achieved local control with a median follow-up of 8 months. 100% of patients with HCC (n = 6) achieved local control. Patients with surgically placed fiducial markers had no complications related to marker placement. Conclusion. Our preliminary results showed that SBRT is a safe and effective local treatment modality in selected patients with liver malignancies with minimal adverse events. Further studies are needed to define its role in the management of these malignancies

    Cutting errors in total knee replacement: Assessment by computer assisted surgery

    Get PDF
    The observed errors in the position of the implanted prosthesis can be due to a number of potential causes. One of these is the potential error during execution of the bone cuts. However, there is only minimal information on this in the current literature. The amount of cutting errors in 40 consecutive total knee replacements was reported. All the operations were done by the same surgeon. The amount of cutting error was measured by the use of computer navigation system. It was hypothesized that there was no difference in the amount of error between bone cut through the cutting slot (slotted cutting) and bone cut done on the surface of the cutting guide (open cutting). It was found that the average absolute cutting error was 1° in the coronal plane and 1.4° in the sagittal plane. Significantly more outlier (more than 3°) was observed in the errors in the sagittal plane (P = 0.014, chi square test). Open cutting resulted in less error in the sagittal plane of the tibial cut when compared with slotted cutting (P = 0.031, Mann-Whitney U Test). This was attributed by the use of a thicker saw blade with higher stiffness in the open cutting method. © 2008 Springer-Verlag.postprin

    Tibial stress fracture after computer-navigated total knee arthroplasty

    Get PDF
    A correct alignment of the tibial and femoral component is one of the most important factors determining favourable long-term results of a total knee arthroplasty (TKA). The accuracy provided by the use of the computer navigation systems has been widely described in the literature so that their use has become increasingly popular in recent years; however, unpredictable complications, such as displaced or stress femoral or tibial fractures, have been reported to occur a few weeks after the operation. We present a case of a stress tibial fracture that occurred after a TKA performed with the use of a computer navigation system. The stress fracture, which eventually healed without further complications, occurred at one of the pinhole sites used for the placement of the tibial trackers

    Identification of Equid herpesvirus 2 in tissue-engineered equine tendon

    Get PDF
    Background: Incidental findings of virus-like particles were identified following electron microscopy of tissue-engineered tendon constructs (TETC) derived from equine tenocytes. We set out to determine the nature of these particles, as there are few studies which identify virus in tendons per se, and their presence could have implications for tissue-engineering using allogenic grafts. Methods: Virus particles were identified in electron microscopy of TETCs. Virion morphology was used to initially hypothesise the virus identity.  Next generation sequencing was implemented to identify the virus. A pan herpesvirus PCR was used to validate the RNASeq findings using an independent platform. Histological analysis and biochemical analysis was undertaken on the TETCs. Results: Morphological features suggested the virus to be either a retrovirus or herpesvirus. Subsequent next generation sequencing mapped reads to Equid herpesvirus 2 (EHV2). Histological examination and biochemical testing for collagen content revealed no significant differences between virally affected TETCs and non-affected TETCs. An independent set of equine superficial digital flexor tendon tissue (n=10) examined using designed primers for specific EHV2 contigs identified at sequencing were negative. These data suggest that EHV is resident in some equine tendon. Conclusions: EHV2 was demonstrated in equine tenocytes for the first time; likely from in vivo infection. The presence of EHV2 could have implications to both tissue-engineering and tendinopathy

    A custom-made guide-wire positioning device for Hip Surface Replacement Arthroplasty: description and first results

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Hip surface replacement arthroplasty (SRA) can be an alternative for total hip arthroplasty. The short and long-term outcome of hip surface replacement arthroplasty mainly relies on the optimal size and position of the femoral component. This can be defined before surgery with pre-operative templating. Reproducing the optimal, templated femoral implant position during surgery relies on guide wire positioning devices in combination with visual inspection and experience of the surgeon. Another method of transferring the templated position into surgery is by navigation or Computer Assisted Surgery (CAS). Though CAS is documented to increase accurate placement particularly in case of normal hip anatomy, it requires bulky equipment that is not readily available in each centre.</p> <p>Methods</p> <p>A custom made neck jig device is presented as well as the results of a pilot study.</p> <p>The device is produced based on data pre-operatively acquired with CT-scan. The position of the guide wire is chosen as the anatomical axis of the femoral neck. Adjustments to the design of the jig are made based on the orthopedic surgeon's recommendations for the drill direction. The SRA jig is designed as a slightly more-than-hemispherical cage to fit the anterior part of the femoral head. The cage is connected to an anterior neck support. Four knifes are attached on the central arch of the cage. A drill guide cylinder is attached to the cage, thus allowing guide wire positioning as pre-operatively planned.</p> <p>Custom made devices were tested in 5 patients scheduled for total hip arthroplasty. The orthopedic surgeons reported the practical aspects of the use of the neck-jig device. The retrieved femoral heads were analyzed to assess the achieved drill place in mm deviation from the predefined location and orientation compared to the predefined orientation.</p> <p>Results</p> <p>The orthopedic surgeons rated the passive stability, full contact with neck portion of the jig and knife contact with femoral head, positive. There were no guide failures. The jig unique position and the number of steps required to put the guide in place were rated 1, while the complexity to put the guide into place was rated 1-2. In all five cases the guide wire was accurately positioned. Maximum angular deviation was 2.9° and maximum distance between insertion points was 2.1 mm.</p> <p>Conclusions</p> <p>Pilot testing of a custom made jig for use during SRA indicated that the device was (1) successfully applied and user friendly and (2) allowed for accurate guide wire placement according to the preoperative plan.</p

    Evidence for high bi-allelic expression of activating Ly49 receptors

    Get PDF
    Stochastic expression is a hallmark of the Ly49 family that encode the main MHC class-I-recognizing receptors of mouse natural killer (NK) cells. This highly polygenic and polymorphic family includes both activating and inhibitory receptor genes and is one of genome's fastest evolving loci. The inhibitory Ly49 genes are expressed in a stochastic mono-allelic manner, possibly under the control of an upstream bi-directional early promoter and show mono-allelic DNA methylation patterns. To date, no studies have directly addressed the transcriptional regulation of the activating Ly49 receptors. Our study shows differences in DNA methylation pattern between activating and inhibitory genes in C57BL/6 and F1 hybrid mouse strains. We also show a bias towards bi-allelic expression of the activating receptors based on allele-specific single-cell RT–PCR in F1 hybrid NK cells for Ly49d and Ly49H expression in Ly49h+/− mice. Furthermore, we have identified a region of high sequence identity with possible transcriptional regulatory capacity for the activating Ly49 genes. Our results also point to a likely difference between NK and T-cells in their ability to transcribe the activating Ly49 genes. These studies highlight the complex regulation of this rapidly evolving gene family of central importance in mouse NK cell function

    The Impact of Contact Isolation on the Quality of Inpatient Hospital Care

    Get PDF
    Background: Contact Isolation is a common hospital infection prevention method that may improve infectious outcomes but may also hinder healthcare delivery. Methods: To evaluate the impact of Contact Isolation on compliance with individual and composite process of care quality measures, we formed four retrospective diagnosis-based cohorts from a 662-bed tertiary-care medical center. Each cohor
    corecore