903 research outputs found

    DESIGNING AND EVALUATION OF DICLOFENAC SODIUM SUSTAINED RELEASE MATRIX TABLETS USING HIBISCUS ROSA-SINENSIS LEAVES MUCILAGE

    Get PDF
    ABSTRACT The main objective of the present investigation was to design matrix tablets of Diclofenac sodium using Hibiscus rosa-sinensis leaves mucilage and to study its release retardant activity in prepared sustained release formulations. Hibiscus rosa-sinensis leaves were evaluated for physicochemical properties. Different matrix tablets of Diclofenac sodium Hibiscus rosa-sinensis leaves mucilage were formulated. The matrix tablets found to have better uniformity of weight, hardness, friability and drug content with low deviated values. The swelling behavior, release rate characteristics and the in-vitro dissolution study proved that the dried Hibiscus rosa-sinensis leaves mucilage can be used as a matrix forming material for preparing sustained release matrix tablets. The kinetics of drug release from selected DHR-5 formulation followed zero order. It was concluded that Hibiscus rosa-sinensis leaves mucilage can be used as an effective matrix forming polymer, to sustain the release of Diclofenac sodium from the formulation

    Super-mini percutaneous nephrolithotomy (SMP) vs retrograde intrarenal surgery (RIRS) in the management of renal calculi <= 2 cm: A propensity matched study

    Get PDF
    Objective: To compare the effectiveness and safety of Super-Mini PCNL (SMP) and Retrograde Intrarenal Surgery (RIRS) in the management of renal calculi ≤ 2 cm. Patients and methods: A prospective, inter-institutional, observational study of patients presenting with renal calculi ≤ 2 cm. Patients underwent either SMP (Group 1) or RIRS (Group 2) and were performed by 2 experienced high-volume surgeons. Results: Between September 2018 and April 2019, 593 patients underwent PCNL and 239 patients had RIRS in two tertiary centers. Among them, 149 patients were included for the final analysis after propensity-score matching out of which 75 patients underwent SMP in one center and 74 patients underwent RIRS in the other. The stone-free rate (SFR) was statistically significantly higher in Group 1 on POD-1 (98.66% vs. 89.19%; p = 0.015), and was still higher in Group 1 on POD-30 (98.66% vs. 93.24%, p = 0.092) SFR on both POD-1 and POD-30 for lower pole calculi was higher in Group 1 (100 vs. 82.61%, p = 0.047 and 100 vs 92.61% p = 0.171). The mean (SD) operative time was significantly shorter in Group 1 at 36.43 min (14.07) vs 51.15 (17.95) mins (p < 0.0001). The mean hemoglobin drop was significantly less in Group 1 (0.31 vs 0.53 gm%; p = 0.020). There were more Clavien–Dindo complications in Group 2 (p = 0.021). The mean VAS pain score was significantly less in Group 2 at 6 and 12 h postoperatively (2.52 vs 3.67, 1.85 vs 2.40, respectively: p < 0.0001), whereas the mean VAS pain score was significantly less in Group 1 at 24 h postoperatively (0.31 vs 1.01, p < 0.0001). The mean hospital stay was significantly shorter in Group 1 (28.37 vs 45.70 h; p < 0.0001). Conclusion: SMP has significantly lower operative times, complication rates, shorter hospital stay, with higher stone-free rates compared to RIRS. SMP is associated with more early post-operative pain though.Manipal Academy of Higher Education, Manipa

    The CMS Outer Hadron Calorimeter

    Get PDF
    The CMS hadron calorimeter is a sampling calorimeter with brass absorber and plastic scintillator tiles with wavelength shifting fibres for carrying the light to the readout device. The barrel hadron calorimeter is complemented with a outer calorimeter to ensure high energy shower containment in CMS and thus working as a tail catcher. Fabrication, testing and calibrations of the outer hadron calorimeter are carried out keeping in mind its importance in the energy measurement of jets in view of linearity and resolution. It will provide a net improvement in missing \et measurements at LHC energies. The outer hadron calorimeter has a very good signal to background ratio even for a minimum ionising particle and can hence be used in coincidence with the Resistive Plate Chambers of the CMS detector for the muon trigger

    Design, Performance and Calibration of the CMS Forward Calorimeter Wedges

    Get PDF
    We report on the test beam results and calibration methods using charged particles of the CMS Forward Calorimeter (HF). The HF calorimeter covers a large pseudorapidity region (3\l |\eta| \le 5), and is essential for large number of physics channels with missing transverse energy. It is also expected to play a prominent role in the measurement of forward tagging jets in weak boson fusion channels. The HF calorimeter is based on steel absorber with embedded fused-silica-core optical fibers where Cherenkov radiation forms the basis of signal generation. Thus, the detector is essentially sensitive only to the electromagnetic shower core and is highly non-compensating (e/h \approx 5). This feature is also manifest in narrow and relatively short showers compared to similar calorimeters based on ionization. The choice of fused-silica optical fibers as active material is dictated by its exceptional radiation hardness. The electromagnetic energy resolution is dominated by photoelectron statistics and can be expressed in the customary form as a/\sqrt{E} + b. The stochastic term a is 198% and the constant term b is 9%. The hadronic energy resolution is largely determined by the fluctuations in the neutral pion production in showers, and when it is expressed as in the electromagnetic case, a = 280% and b = 11%

    Energy Response and Longitudinal Shower Profiles Measured in CMS HCAL and Comparison With Geant4

    Get PDF
    The response of the CMS combined electromagnetic and hadron calorimeter to beams of pions with momenta in the range 5-300 GeV/c has been measured in the H2 test beam at CERN. The raw response with the electromagnetic compartment calibrated to electrons and the hadron compartment calibrated to 300 GeV pions may be represented by sigma = (1.2) sqrt{E} oplus (0.095) E. The fraction of energy visible in the calorimeter ranges from 0.72 at 5 GeV to 0.95 at 300 GeV, indicating a substantial nonlinearity. The intrinsic electron to hadron ratios are fit as a function of energy and found to be in the range 1.3-2.7 for the electromagnetic compartment and 1.4-1.8 for the hadronic compartment. The fits are used to correct the non-linearity of the e pi response to 5% over the entire measured range resulting in a substantially improved resolution at low energy. Longitudinal shower profile have been measured in detail and compared to Geant4 models, LHEP-3.7 and QGSP-2.8. At energies below 30 GeV, the data, LHEP and QGSP are in agreement. Above 30 GeV, LHEP gives a more accurate simulation of the longitudinal shower profile
    • …
    corecore