34 research outputs found
Unconventional Uses of Microcantilevers as Chemical Sensors in Gas and Liquid Media
The use of microcantilevers as (bio)chemical sensors usually involves the application of a chemically sensitive layer. The coated device operates either in a static bending regime or in a dynamic flexural mode. While some of these coated devices may be operated successfully in both the static and the dynamic modes, others may suffer from certain shortcomings depending on the type of coating, the medium of operation and the sensing application. Such shortcomings include lack of selectivity and reversibility of the sensitive coating and a reduced quality factor due to the surrounding medium. In particular, the performance of microcantilevers excited in their standard out-of-plane dynamic mode drastically decreases in viscous liquid media. Moreover, the responses of coated cantilevers operating in the static bending mode are often difficult to interpret. To resolve these performance issues, the following emerging unconventional uses of microcantilevers are reviewed in this paper: (1) dynamic-mode operation without using a sensitive coating, (2) the use of in-plane vibration modes (both flexural and longitudinal) in liquid media, and (3) incorporation of viscoelastic effects in the coatings in the static mode of operation. The advantages and drawbacks of these atypical uses of microcantilevers for chemical sensing in gas and liquid environments are discussed
Unconventional Uses of Cantilevers for Chemical Sensing in Gas and Liquid Environments
Microcantilevers used as (bio)chemical sensors are usually coated with a chemically sensitive layer. The coated devices operate either in a static bending regime or in a dynamic flexural mode. While the coated devices operate generally well in both the static and dynamic mode, they do suffer from certain shortcomings depending on the medium of operation and the application, including lack of selectivity and of reversibility of the sensitive coating and a reduced quality factor due to the surrounding medium. In particular, the performance of microcantilevers excited in their standard out-of-plane dynamic mode drastically decreases in viscous liquid media. Moreover, the responses of coated cantilevers operating in the static bending mode are often difficult to interpret. To resolve those performance issues, unconventional uses of microcantilever are reviewed in this paper, which consist of the use of the dynamic mode without sensitive coating, the use of in-plane (flexural and longitudinal) vibration modes in liquid media, and fully accounting for the viscoelastic effects of the coatings in the static mode of operation. The advantages and drawbacks of these unconventional uses of microcantilevers for chemical sensing in gas and liquid environments are discussed
Effect of Hydrodynamic Force on Microcantilever Vibrations: Applications to Liquid-Phase Chemical Sensing
At the microscale, cantilever vibrations depend not only on the microstructure’s properties and geometry but also on the properties of the surrounding medium. In fact, when a microcantilever vibrates in a fluid, the fluid offers resistance to the motion of the beam. The study of the influence of the hydrodynamic force on the microcantilever’s vibrational spectrum can be used to either (1) optimize the use of microcantilevers for chemical detection in liquid media or (2) extract the mechanical properties of the fluid. The classical method for application (1) in gas is to operate the microcantilever in the dynamic transverse bending mode for chemical detection. However, the performance of microcantilevers excited in this standard out-of-plane dynamic mode drastically decreases in viscous liquid media. When immersed in liquids, in order to limit the decrease of both the resonant frequency and the quality factor, and improve sensitivity in sensing applications, alternative vibration modes that primarily shear the fluid (rather than involving motion normal to the fluid/beam interface) have been studied and tested: these include in-plane vibration modes (lateral bending mode and elongation mode). For application (2), the classical method to measure the rheological properties of fluids is to use a rheometer. However, such systems require sampling (no in-situ measurements) and a relatively large sample volume (a few milliliters). Moreover, the frequency range is limited to low frequencies (less than 200Hz). To overcome the limitations of this classical method, an alternative method based on the use of silicon microcantilevers is presented. The method, which is based on the use of analytical equations for the hydrodynamic force, permits the measurement of the complex shear modulus of viscoelastic fluids over a wide frequency range
Influence of Fluid-Structure Interaction on Microcantilever Vibrations: Applications to Rheological Fluid Measurement and Chemical Detection
At the microscale, cantilever vibrations depend not only on the microstructure’s properties and geometry but also on the properties of the surrounding medium. In fact, when a microcantilever vibrates in a fluid, the fluid offers resistance to the motion of the beam. The study of the influence of the hydrodynamic force on the microcantilever’s vibrational spectrum can be used to either (1) optimize the use of microcantilevers for chemical detection in liquid media or (2) extract the mechanical properties of the fluid. The classical method for application (1) in gas is to operate the microcantilever in the dynamic transverse bending mode for chemical detection. However, the performance of microcantilevers excited in this standard out-of-plane dynamic mode drastically decreases in viscous liquid media. When immersed in liquids, in order to limit the decrease of both the resonant frequency and the quality factor, alternative vibration modes that primarily shear the fluid (rather than involving motion normal to the fluid/beam interface) have been studied and tested: these include inplane vibration modes (lateral bending mode and elongation mode). For application (2), the classical method to measure the rheological properties of fluids is to use a rheometer. To overcome the limitations of this classical method, an alternative method based on the use of silicon microcantilevers is presented. The method, which is based on the use of analytical equations for the hydrodynamic force, permits the measurement of the complex shear modulus of viscoelastic fluids over a wide frequency range
The DAily Home LIfe Activity Dataset: A High Semantic Activity Dataset for Online Recognition
Conference of 12th IEEE International Conference on Automatic Face and Gesture Recognition, FG 2017 ; Conference Date: 30 May 2017 Through 3 June 2017; Conference Code:128713International audienceIn this article, we introduce the DAily Home LIfe Activity (DAHLIA) Dataset, a new dataset adapted to the context of smart-home or video-assistance. Videos were recorded in realistic conditions, with 3 KinectTMv2 sensors located as they would be in a real context. The very long-range activities were performed in an unconstrained way (participants received few instructions), and in a continuous (untrimmed) sequence, resulting in long videos (39 min in average per subject). Contrary to previously published databases, in which labeled actions are very short and with low-semantic level, this new database focuses on high-level semantic activities such as 'Preparing lunch' or 'House Working'. As a baseline, we evaluated several metrics on three different algorithms designed for online action recognition or detection
Deeply optimized Hough transform: Application to action segmentation
Conference of 17th International Conference on Image Analysis and Processing, ICIAP 2013 ; Conference Date: 9 September 2013 Through 13 September 2013; Conference Code:99647International audienceHough-like methods like Implicit Shape Model (ISM) and Hough forest have been successfully applied in multiple computer vision fields like object detection, tracking, skeleton extraction or human action detection. However, these methods are known to generate false positives. To handle this issue, several works like Max-Margin Hough Transform (MMHT) or Implicit Shape Kernel (ISK) have reported significant performance improvements by adding discriminative parameters to the generative ones introduced by ISM. In this paper, we offer to use only discriminative parameters that are globally optimized according to all the variables of the Hough transform. To this end, we abstract the common vote process of all Hough methods into linear equations, leading to a training formulation that can be solved using linear programming solvers. Our new Hough Transform significantly outperforms the previous ones on HoneyBee and TUM datasets, two public databases of action and behaviour segmentation