17,232 research outputs found

    Multilayer infrared beamsplitter film system

    Get PDF
    Multilayer infrared beamsplitter film system on a potassium bromide crystal substrate is operational over a wavelength range of 2.5 to 25 microns with nearly equal broadband reflectance and transmittance. It is useful in optical coating, vacuum deposition, radiometry, interferometry, and spectrometry

    High efficiency optical beamsplitter designed for operation in the infrared region

    Get PDF
    Beamsplitter system uses potassium bromide as substrate for operating in the spectral region between 5 and 30 microns and calcium fluoride for narrowband applications. It uses a 13-layer film which yields nearly equal broadband infrared reflectance and transmittance

    Field Studies of Sedimentary Sequences in Eastern Hurd Peninsula Central Livingston Island, South Shetland Islands

    Get PDF

    The role of gravity on macrosegregation in alloys

    Get PDF
    During dendritic solidification liquid flow is induced both by buoyancy forces and solidification shrinkage. There is strong evidence that the major reason for the liquid flow is the former, i.e., thermosolutal convection. In the microgravity environment, it is thought that the thermosolutal convection will be greatly diminished so that convection will be confined mainly to the flow of interdendritic liquid required to satisfy the solidification shrinkage. An attempt is made to provide improved models of dendritic solidification with emphasis on convection and macrosegregation. Macrosegregation is an extremely important subject to the commercial casting community. The simulation of thermosolutal convection in directionally solidified (DS) alloys is described. A linear stability analysis was used to predict marginal stability curves for a system that comprises a mushy zone underlying an all-liquid zone. The supercritical thermosolutal convection in directionally solidified dendritic alloys was also modeled. The model assumes a nonconvective initial state with planar and horizontal isotherms and isoconcentration that move upward at a constant solidification velocity. Results are presented for systems involving lead-tin alloys and show significant differences with results of plane-front solidification

    Cross sections for the production of fragments with Z greater than or equal to 8 by fragmentation of Z greater than or equal to 9 and less than or equal to 26 nuclei

    Get PDF
    Charge changing nuclear collisions in plastic nuclear track detectors were studied using a new experimental technique of automatic track measurement for etched tracks in plastic detectors. Partial cross sections for the production of fragments of charge Z approximately 8 were measured for projectile nuclei of charge 9 approximately Z approximately 26 in the detector material CR39 and in silver. for this purpose three independent experiments were performed using Bevalac beams. The first one was an exposure of a stack of CR39 plastic plates to 1.8 GeV/nucl. Ar-40 nuclei. The second one was an exposure of another CR39 stack of 1.7 GeV/nucl. Fe-56 projectiles. In the third experiment a mixed stack of CR39 plates and silver foils was irradiated with 1.7 GeV/nucl. Fe-56 nuclei. Thus the measurement of nuclear cross sections in a light target (CR39 = C12H18O7) and as well in a heavy target (silver) was possible

    Measuring the effect of airway pressure on pulmonary arterial diameter in the intact rat lung

    Get PDF
    To study the relationship between transpulomnary pressure (Ptp), intravascular pressure (Pv), and the pulmonary arterial tree structure, morphometric measurements of pulmonary arterial trees were made in intact lungs from Sprague-Dawley rats. Using cone beam micro-CT and techniques we developed for imaging small animal lungs, volumetric CT data were acquired for Ptp from 0 - 12 mmHg and Pv from 5 - 30 mmHg. The diameter, D (measured range approximately 0.08-2.0 mm), vs. pressure, P, relation can be described by D(P) = D(0)(1+ α P), where α is a distensibility coefficient. Unlike studies performed in larger animals, where changes in either Ptp or Pv had nearly identical effect on vessel distensibility, we found that there is only a small dependence of arterial diameter on Ptp in the rat. For example, using the above relation where P=Ptp and Pv is held constant at 12mmHg, alpha = 0.55±0.42(SE) %/mmHg, compared with when P=Pv and Ptp is held at 12mmHg, alpha = 2.59±0.17(SE) %/mmHg
    corecore