86 research outputs found

    Object Recognition using Isolumes

    Get PDF

    Increasing Respiratory Effort With 100% Oxygen During Resuscitation of Preterm Rabbits at Birth

    Get PDF
    Background: Spontaneous breathing is essential for successful non-invasive respiratory support delivered by a facemask at birth. As hypoxia is a potent inhibitor of spontaneous breathing, initiating respiratory support with a high fraction of inspired O2 may reduce the risk of hypoxia and increase respiratory effort at birth. Methods: Preterm rabbit kittens (29 days gestation, term ~32 days) were delivered and randomized to receive continuous positive airway pressure with either 21% (n = 12) or 100% O2 (n = 8) via a facemask. If apnea occurred, intermittent positive pressure ventilation (iPPV) was applied with either 21% or 100% O2 in kittens who started in 21% O2, and remained at 100% O2 for kittens who started the experiment in 100% O2. Respiratory rate (breaths per minute, bpm) and variability in inter-breath interval (%) were measured from esophageal pressure recordings and functional residual capacity (FRC) was measured from synchrotron phase-contrast X-ray images. Results: Initially, kittens receiving 21% O2 had a significantly lower respiratory rate and higher variability in inter-breath interval, indicating a less stable breathing pattern than kittens starting in 100% O2 [median (IQR) respiratory rate: 16 (4–28) vs. 38 (29–46) bpm, p = 0.001; variability in inter-breath interval: 33.3% (17.2–50.1%) vs. 27.5% (18.6–36.3%), p = 0.009]. Apnea that required iPPV, was more frequently observed in kittens in whom resuscitation was started with 21% compared to 100% O2 (11/12 vs. 1/8, p = 0.001). After recovering from apnea, respiratory rate was significantly lower and variability in inter-breath interval was significantly higher in kittens who received iPPV with 21% compared to 100% O2. FRC was not different between study groups at both timepoints. Conclusion: Initiating resuscitation with 100% O2 resulted in increased respiratory activity and stability, thereby reducing the risk of apnea and need for iPPV after birth. Further studies in human preterm infants are mandatory to confirm the benefit of this approach in terms of oxygenation. In addition, the ability to avoid hyperoxia after initiation of resuscitation with 100% oxygen, using a titration protocol based on oxygen saturation, needs to be clarified

    Phosphorylation and Transport in the Na-K-2Cl Cotransporters, NKCC1 and NKCC2A, Compared in HEK-293 Cells

    Get PDF
    Na-K-2Cl cotransporters help determine cell composition and volume. NKCC1 is widely distributed whilst NKCC2 is only found in the kidney where it plays a vital role reabsorbing 20% of filtered NaCl. NKCC2 regulation is poorly understood because of its restricted distribution and difficulties with its expression in mammalian cell cultures. Here we compare phosphorylation of the N-termini of the cotransporters, measured with phospho-specific antibodies, with bumetanide-sensitive transport of K+ (86Rb+) (activity) in HEK-293 cells stably expressing fNKCC1 or fNKCC2A which were cloned from ferret kidney. Activities of transfected transporters were distinguished from those of endogenous ones by working at 37°C. fNKCC1 and fNKCC2A activities were highest after pre-incubation of cells in hypotonic low-[Cl−] media to reduce cell [Cl−] and volume during flux measurement. Phosphorylation of both transporters more than doubled. Pre-incubation with ouabain also strongly stimulated fNKCC1 and fNKCC2A and substantially increased phosphorylation, whereas pre-incubation in Na+-free media maximally stimulated fNKCC1 and doubled its phosphorylation, but inhibited fNKCC2A, with a small increase in its phosphorylation. Kinase inhibitors halved phosphorylation and activity of both transporters whereas inhibition of phosphatases with calyculin A strongly increased phosphorylation of both transporters but only slightly stimulated fNKCC1 and inhibited fNCCC2A. Thus kinase inhibition reduced phosphorylation and transport, and transport stimulation was only seen when phosphorylation increased, but transport did not always increase with phosphorylation. This suggests phosphorylation of the N-termini determines the transporters' potential capacity to move ions, but final activity also depends on other factors. Transport cannot be reliably inferred solely using phospho-specific antibodies on whole-cell lysates

    Validation of disease-specific biomarkers for the early detection of bronchopulmonary dysplasia

    Get PDF
    OBJECTIVE: To demonstrate and validate the improvement of current risk stratification for bronchopulmonary dysplasia (BPD) early after birth by plasma protein markers (sialic acid-binding lg-like lectin 14 (SIGLEC-14), basal cell adhesion molecule (BCAM), angiopoietin-like 3 protein (ANGPTL-3)) in extremely premature infants.METHODS AND RESULTS: Proteome screening in first-week-of-life plasma samples of n- 52 preterm infants <32 weeks gestational age (GA) on two proteomic platforms (SomaLogic (R), Olink-Proteomics (R)) confirmed three biomarkers with significant predictive power: BCAM, SIGLEC-14, and ANGPTL-3. We demonstrate high sensitivity (0.92) and specificity (0.86) under consideration of GA, show the proteins' critical contribution to the predictive power of known clinical risk factors, e.g., birth weight and GA, and predicted the duration of mechanical ventilation, oxygen supplementation, as well as neonatal intensive care stay. We confirmed significant predictive power for BPD cases when switching to a clinically applicable method (enzyme-linked immunosorbent assay) in an independent sample set (n = 25, p < 0.001) and demonstrated disease specificity in different cohorts of neonatal and adult lung disease.CONCLUSION: While successfully addressing typical challenges of clinical biomarker studies, we demonstrated the potential of BCAM, SIGLEC-14, and ANGPTL-3 to inform future clinical decision making in the preterm infant at risk for BPD.Analytical BioScience

    Increasing Respiratory Effort With 100% Oxygen During Resuscitation of Preterm Rabbits at Birth

    Get PDF
    Background: Spontaneous breathing is essential for successful non-invasive respiratory support delivered by a facemask at birth. As hypoxia is a potent inhibitor of spontaneous breathing, initiating respiratory support with a high fraction of inspired O2 may reduce the risk of hypoxia and increase respiratory effort at birth. Methods: Preterm rabbit kittens (29 days gestation, term ~32 days) were delivered and randomized to receive continuous positive airway pressure with either 21% (n = 12) or 100% O2 (n = 8) via a facemask. If apnea occurred, intermittent positive pressure ventilation (iPPV) was applied with either 21% or 100% O2 in kittens who started in 21% O2, and remained at 100% O2 for kittens who started the experiment in 100% O2. Respiratory rate (breaths per minute, bpm) and variability in inter-breath interval (%) were measured from esophageal pressure recordings and functional residual capacity (FRC) was measured from synchrotron phase-contrast X-ray images. Results: Initially, kittens receiving 21% O2 had a significantly lower respiratory rate and higher variability in inter-breath interval, indicating a less stable breathing pattern than kittens starting in 100% O2 [median (IQR) respiratory rate: 16 (4–28) vs. 38 (29–46) bpm, p = 0.001; variability in inter-breath interval: 33.3% (17.2–50.1%) vs. 27.5% (18.6–36.3%), p = 0.009]. Apnea that required iPPV, was more frequently observed in kittens in whom resuscitation was started with 21% compared to 100% O2 (11/12 vs. 1/8, p = 0.001). After recovering from apnea, respiratory rate was significantly lower and variability in inter-breath interval was significantly higher in kittens who received iPPV with 21% compared to 100% O2. FRC was not different between study groups at both timepoints. Conclusion: Initiating resuscitation with 100% O2 resulted in increased respiratory activity and stability, thereby reducing the risk of apnea and need for iPPV after birth. Further studies in human preterm infants are mandatory to confirm the benefit of this approach in terms of oxygenation. In addition, the ability to avoid hyperoxia after initiation of resuscitation with 100% oxygen, using a titration protocol based on oxygen saturation, needs to be clarified

    Analysis of the stochastic excursions of tumbling apples

    No full text
    Publishe

    Validity and reliability of Life Cycle Assessment: A case study of New Zealand Dairy Production

    No full text
    The purpose of this work is to evaluate the validity and reliability of life cycle assessment as a research methodology to measure the ecological footprint of New Zealand’s dairy production (by the dairy farming and dairy processing sectors). Environmental Input-Output Analysis was used as a macro-level life cycle assessment tool and applied to the dairy production over a period of six years. Eco-efficiencies were used as performance metrics to assess the sustainability of the dairy production. Over the six year period, New Zealand’s annual milk production increased from 11.4 to 15.1 million tonnes and its annual production of dairy products increased from 1.9 to 2.6 million tonnes. Eco-efficiencies indicate that over this time dairy farming became significantly more efficient in terms of land use (-27%), electricity use (-12%), water use (-21%) and lime use (-16%) and produced significantly less water-based effluent (-20%). At the same time fuel and fertilizer use were slightly less efficient (increasing by 2% and 6% respectively). The dairy processing industry used 21% less water and discharged 21% less effluent water. Fuel used in milk transportation was 14% more efficient. The internal validity of the research was good despite significant structural changes to the dairy processing sector but commercial sensitivity had a negative impact on the results. External validity was affected by different boundaries, different climates and different time frames for published studies but some comparisons were possible. The underlying data was generally accurate, reproducible and representative of the entire sectors with checks for anomalies to ensure good reliability. The choice of Environmental Input-Output Analysis for the life cycle assessment tool and error analysis of all underlying data contributed to both the validity of the research method and the reliability of the data. These, in turn, give good credibility to the research findings.fals

    A high-temperature gas heater

    No full text
    • …
    corecore