136 research outputs found

    Long-term clinical effects of ventricular pacing reduction with a changeover mode to minimize ventricular pacing in a general pacemaker population

    Get PDF
    AIM: Right ventricular pacing (VP) has been hypothesized to increase the risk in heart failure (HF) and atrial fibrillation (AF). The ANSWER study evaluated, whether an AAI-DDD changeover mode to minimize VP (SafeR) improves outcome compared with DDD in a general dual-chamber pacemaker population. METHODS AND RESULTS: ANSWER was a randomized controlled multicentre trial assessing SafeR vs. standard DDD in sinus node disease (SND) or AV block (AVB) patients. After a 1-month run-in period, they were randomized (1 : 1) and followed for 3 years. Pre-specified co-primary end-points were VP and the composite of hospitalization for HF, AF, or cardioversion. Pre-specified secondary end-points were cardiac death or HF hospitalizations and cardiovascular hospitalizations. ANSWER enrolled 650 patients (52.0% SND, 48% AVB) at 43 European centres and randomized in SafeR (n = 314) or DDD (n = 318). The SafeR mode showed a significant decrease in VP compared with DDD (11.5 vs. 93.6%, P < 0.0001 at 3 years). Deaths and syncope did not differ between randomization arms. No significant difference between groups [HR = 0.78; 95% CI (0.48-1.25); P = 0.30] was found in the time to event of the co-primary composite of hospitalization for HF, AF, or cardioversion, nor in the individual components. SafeR showed a 51% risk reduction (RR) in experiencing cardiac death or HF hospitalization [HR = 0.49; 95% CI (0.27-0.90); P = 0.02] and 30% RR in experiencing cardiovascular hospitalizations [HR = 0.70; 95% CI (0.49-1.00); P = 0.05]. CONCLUSION: SafeR safely and significantly reduced VP in a general pacemaker population though had no effect on hospitalization for HF, AF, or cardioversion, when compared with DDD

    Effectiveness and safety of a single freeze strategy of cryoballoon ablation of atrial fibrillation: an EHRA systematic review and meta-analysis

    Get PDF
    To conduct a systematic review and meta-analysis to compare the effectiveness and safety of cryoballoon ablation of atrial fibrillation (AF) performed using a single freeze strategy in comparison to an empiric double ('bonus') freeze strategy. We systematically searched MEDLINE, EMBASE, and CENTRAL databases from inception to 12 July 2020, for prospective and retrospective studies of patients undergoing cryoballoon for paroxysmal or persistent AF comparing a single vs. bonus freeze strategy. The main outcome was atrial arrhythmia-free survival and eligible studies required at least 12 months of follow-up; the primary safety outcome was a composite of all complications. Study quality was assessed using the Cochrane risk of bias tool and the Newcastle-Ottawa Scale. Thirteen studies (3 randomized controlled trials and 10 observational studies) comprising 3163 patients were eligible for inclusion (64% males, 71.5% paroxysmal AF, mean CHA2DS2-VASc score 1.3 ± 0.9). There was no significant difference in pooled effectiveness between single freeze strategy compared to double freeze strategy [relative risk (RR) 1.03; 95% confidence interval (CI): 0.98-1.07; I2 = 0%]. Single freeze procedures were associated with a significantly lower adverse event rate (RR 0.72; 95% CI: 0.53-0.98; I2 = 0%) and shorter average procedure time (90 ± 27 min vs. 121 ± 36 min, P < 0.001). A trend for lower risk of persistent phrenic nerve palsy was observed (RR 0.61; 95% CI: 0.37-1.01; I2 = 0%). The quality of included studies was moderate/good, with no evidence of significant publication bias. Single freeze strategy for cryoballoon of AF is as effective as an empiric double ('bonus') freeze strategy while appearing safer and probably quicker

    Implantable cardioverter defibrillator therapy for primary prevention of sudden cardiac death in the real world: Main findings from the French multicentre DAI-PP programme (pilot phase)

    Get PDF
    This review summarizes the main findings of the French multicentre DAI-PP pilot programme, and discusses the related clinical and research perspectives. This project included retrospectively (2002–2012 period) more than 5000 subjects with structural heart disease who received an implantable cardioverter defibrillator (ICD) for primary prevention of sudden cardiac death, and were followed for a mean period of 3 years. The pilot phase of the DAI-PP programme has provided valuable information on several practical and clinically relevant aspects of primary prevention ICD implantation in the real-world population, which are summarized in this review. This pilot has led to a prospective evaluation that started in May 2018, assessing ICD therapy in primary and secondary prevention in patients with structural and electrical heart diseases, with remote monitoring follow-up using a dedicated platform. This should further enhance our understanding of sudden cardiac death, to eventually optimize the field of preventative actions

    Impact of Type-2 Diabetes Mellitus on the Outcomes of Catheter Ablation of Atrial Fibrillation (European observational multicentre study)

    Get PDF
    Type-2 diabetes mellitus (DM) is associated with an increased risk of atrial fibrillation (AF). It is unclear whether DM is a risk factor for arrhythmia recurrence following catheter ablation of AF. We performed a nonrandomised, observational study in 7 high-volume European centres. A total of 2,504 patients who underwent catheter ablation of AF were included, and procedural outcomes were compared among patients with or without DM. Patients with DM (234) accounted for 9.3% of the sample, and were significantly older, had a higher BMI and suffered more frequently from persistent AF. Arrhythmia relapses at 12 months after AF ablation occurred more frequently in the DM group (32.0% vs 25.3%, p = 0.031). After adjusting for type of AF (i.e., paroxysmal vs persistent), during a median follow-up of 17 ± 16 months, atrial arrhythmia free-survival was lower in the diabetics with persistent AF (log-rank p = 0.003), and comparable for paroxysmal AF (log-rank p = 0.554). These results were confirmed in a propensity-matched analysis, and DM was also an independent predictor of AF recurrence on the multivariate analysis (hazard ratio 1.39; 95% confidence interval 95%1.07 to 1.88; p = 0.016). There was no significant difference in the rate of periprocedural complications among DM and non-DM patients (3.8% vs 6.3%, p = 0.128). Efficacy and safety of cryoballoon ablation were comparable to radiofrequency ablation in both DM and no-DM groups. In conclusion, catheter ablation of AF appears to be safe in patients with DM. However, DM is associated with higher rate of atrial arrhythmia relapse, particularly for patients with persistent AF

    Catheter Ablation of Atrial Fibrillation in Patients with Previous Lobectomy or Partial Lung Resection: Long-Term Results of an International Multicenter Study

    Full text link
    Introduction: Data regarding the efficacy of catheter ablation in patients with atrial fibrillation (AF) and patients' previous history of pulmonary lobectomy/pneumonectomy are scanty. We sought to evaluate the efficacy and long-term follow-up of catheter ablation in this highly selected group of patients. Material and Methods: Twenty consecutive patients (8 females, 40%; median age 65.2 years old) with a history of pneumonectomy/lobectomy and paroxysmal or persistent AF, treated by means of pulmonary vein isolation (PVI) at ten participating centers were included. Procedural success, intra-procedural complications, and AF recurrences were considered. Results: Fifteen patients had a previous lobectomy and five patients had a complete pneumonectomy. A large proportion (65%) of PV stumps were electrically active and represented a source of firing in 20% of cases. PVI was performed by radiofrequency ablation in 13 patients (65%) and by cryoablation in the remaining 7 cases. Over a median follow up of 29.7 months, a total of 7 (33%) AF recurrences were recorded with neither a difference between patients treated with cryoablation or radiofrequency ablation or between the two genders. Conclusions: Catheter ablation by radiofrequency ablation or cryoablation in patients with pulmonary stumps is feasible and safe. Long-term outcomes are favorable, and a similar efficacy of catheter ablation has been noticed in both males and females

    Quality indicators for the care and outcomes of adults with atrial fibrillation

    Get PDF
    Aims To develop quality indicators (QIs) that may be used to evaluate the quality of care and outcomes for adults with atrial fibrillation (AF). Methods and results We followed the ESC methodology for QI development. This methodology involved (i) the identification of the domains of AF care for the diagnosis and management of AF (by a group of experts including members of the ESC Clinical Practice Guidelines Task Force for AF); (ii) the construction of candidate QIs (including a systematic review of the literature); and (iii) the selection of the final set of QIs (using a modified Delphi method). Six domains of care for the diagnosis and management of AF were identified: (i) Patient assessment (baseline and follow-up), (ii) Anticoagulation therapy, (iii) Rate control strategy, (iv) Rhythm control strategy, (v) Risk factor management, and (vi) Outcomes measures, including patient-reported outcome measures (PROMs). In total, 17 main and 17 secondary QIs, which covered all six domains of care for the diagnosis and management of AF, were selected. The outcome domain included measures on the consequences and treatment of AF, as well as PROMs. Conclusion This document defines six domains of AF care (patient assessment, anticoagulation, rate control, rhythm control, risk factor management, and outcomes), and provides 17 main and 17 secondary QIs for the diagnosis and management of AF. It is anticipated that implementation of these QIs will improve the quality of AF care

    A Primary Prevention Clinical Risk Score Model for Patients With Brugada Syndrome (BRUGADA-RISK)

    Get PDF
    OBJECTIVES: The goal of this study was to develop a risk score model for patients with Brugada syndrome (BrS). BACKGROUND: Risk stratification in BrS is a significant challenge due to the low event rates and conflicting evidence. METHODS: A multicenter international cohort of patients with BrS and no previous cardiac arrest was used to evaluate the role of 16 proposed clinical or electrocardiogram (ECG) markers in predicting ventricular arrhythmias (VAs)/sudden cardiac death (SCD) during follow-up. Predictive markers were incorporated into a risk score model, and this model was validated by using out-of-sample cross-validation. RESULTS: A total of 1,110 patients with BrS from 16 centers in 8 countries were included (mean age 51.8 ± 13.6 years; 71.8% male). Median follow-up was 5.33 years; 114 patients had VA/SCD (10.3%) with an annual event rate of 1.5%. Of the 16 proposed risk factors, probable arrhythmia-related syncope (hazard ratio [HR]: 3.71; p < 0.001), spontaneous type 1 ECG (HR: 3.80; p < 0.001), early repolarization (HR: 3.42; p < 0.001), and a type 1 Brugada ECG pattern in peripheral leads (HR: 2.33; p < 0.001) were associated with a higher risk of VA/SCD. A risk score model incorporating these factors revealed a sensitivity of 71.2% (95% confidence interval: 61.5% to 84.6%) and a specificity of 80.2% (95% confidence interval: 75.7% to 82.3%) in predicting VA/SCD at 5 years. Calibration plots showed a mean prediction error of 1.2%. The model was effectively validated by using out-of-sample cross-validation according to country. CONCLUSIONS: This multicenter study identified 4 risk factors for VA/SCD in a primary prevention BrS population. A risk score model was generated to quantify risk of VA/SCD in BrS and inform implantable cardioverter-defibrillator prescription

    Device complications with addition of defibrillation to cardiac resynchronisation therapy for primary prevention

    Get PDF
    Objective: In patients indicated for cardiac resynchronisation therapy (CRT), the choice between a CRT-pacemaker (CRT-P) versus defibrillator (CRT-D) remains controversial and indications in this setting have not been well delineated. Apart from inappropriate therapies, which are inherent to the presence of a defibrillator, whether adding defibrillator to CRT in the primary prevention setting impacts risk of other acute and late device-related complications has not been well studied and may bear relevance for device selection. // Methods: Observational multicentre European cohort study of 3008 consecutive patients with ischaemic or non-ischaemic dilated cardiomyopathy and no history of sustained ventricular arrhythmias, undergoing CRT implantation with (CRT-D, n=1785) or without (CRT-P, n=1223) defibrillator. Using propensity score and competing risk analyses, we assessed the risk of significant device-related complications requiring surgical reintervention. Inappropriate shocks were not considered except those due to lead malfunction requiring lead revision. // Results: Acute complications occurred in 148 patients (4.9%), without significant difference between groups, even after considering potential confounders (OR=1.20, 95% CI 0.72 to 2.00, p=0.47). During a mean follow-up of 41.4±29 months, late complications occurred in 475 patients, giving an annual incidence rate of 26 (95% CI 9 to 43) and 15 (95% CI 6 to 24) per 1000 patient-years in CRT-D and CRT-P patients, respectively. CRT-D was independently associated with increased occurrence of late complications (HR=1.68, 95% CI 1.27 to 2.23, p=0.001). In particular, when compared with CRT-P, CRT-D was associated with an increased risk of device-related infection (HR 2.10, 95% CI 1.18 to 3.45, p=0.004). Acute complications did not predict overall late complications, but predicted device-related infection (HR 2.85, 95% CI 1.71 to 4.56, p<0.001). // Conclusions: Compared with CRT-P, CRT-D is associated with a similar risk of periprocedural complications but increased risk of long-term complications, mainly infection. This needs to be considered in the decision of implanting CRT with or without a defibrillator
    • …
    corecore