3,379 research outputs found

    Automated patient monitoring system

    Get PDF
    Radio-linked patient monitoring system collects several channels of physiological data from as many as 64 hospital patients and transmits the data in digital form to a central control station. The system consists of a central control station and battery-operated patient units comprising small strap-on electronics packages

    An RShiny app for modelling environmental DNA data: accounting for false positive and false negative observation error

    Get PDF
    Environmental DNA (eDNA) surveys have become a popular tool for assessing the distribution of species. However, it is known that false positive and false negative observation error can occur at both stages of eDNA surveys, namely the field sampling stage and laboratory analysis stage. We present an RShiny app that implements the Griffin et al. (2020) statistical method, which accounts for false positive and false negative errors in both stages of eDNA surveys that target single species using quantitative PCR methods. Following Griffin et al. (2020), we employ a Bayesian approach and perform efficient Bayesian variable selection to identify important predictors for the probability of species presence as well as the probabilities of observation error at either stage. We demonstrate the RShiny app using a data set on great crested newts collected by Natural England in 2018, and we identify water quality, pond area, fish presence, macrophyte cover and frequency of drying as important predictors for species presence at a site. The state-of-the-art statistical method that we have implemented is the only one that has specifically been developed for the purposes of modelling false negative and false positive observation error in eDNA data. Our RShiny app is user-friendly, requires no prior knowledge of R and fits the models very efficiently. Therefore, it should be part of the tool-kit of any researcher or practitioner who is collecting or analysing eDNA data

    Changes in Exercise Data Management

    Get PDF
    The suite of exercise hardware aboard the International Space Station (ISS) generates an immense amount of data. The data collected from the treadmill, cycle ergometer, and resistance strength training hardware are basic exercise parameters (time, heart rate, speed, load, etc.). The raw data are post processed in the laboratory and more detailed parameters are calculated from each exercise data file. Updates have recently been made to how this valuable data are stored, adding an additional level of data security, increasing data accessibility, and resulting in overall increased efficiency of medical report delivery. Questions regarding exercise performance or how exercise may influence other variables of crew health frequently arise within the crew health care community. Inquiries over the health of the exercise hardware often need quick analysis and response to ensure the exercise system is operable on a continuous basis. Consolidating all of the exercise system data in a single repository enables a quick response to both the medical and engineering communities. A SQL server database is currently in use, and provides a secure location for all of the exercise data starting at ISS Expedition 1 - current day. The database has been structured to update derived metrics automatically, making analysis and reporting available within minutes of dropping the inflight data it into the database. Commercial tools were evaluated to help aggregate and visualize data from the SQL database. The Tableau software provides manageable interface, which has improved the laboratory's output time of crew reports by 67%. Expansion of the SQL database to be inclusive of additional medical requirement metrics, addition of 'app-like' tools for mobile visualization, and collaborative use (e.g. operational support teams, research groups, and International Partners) of the data system is currently being explored

    The Evolution of Exercise Hardware on ISS: Past, Present, and Future

    Get PDF
    During 16 years in low-Earth orbit, the suite of exercise hardware aboard the International Space Station (ISS) has matured significantly. Today, the countermeasure system supports an array of physical-training protocols and serves as an extensive research platform. Future hardware designs are required to have smaller operational envelopes and must also mitigate known physiologic issues observed in long-duration spaceflight. Taking lessons learned from the long history of space exercise will be important to successful development and implementation of future, compact exercise hardware. The evolution of exercise hardware as deployed on the ISS has implications for future exercise hardware and operations. Key lessons learned from the early days of ISS have helped to: 1. Enhance hardware performance (increased speed and loads). 2. Mature software interfaces. 3. Compare inflight exercise workloads to pre-, in-, and post-flight musculoskeletal and aerobic conditions. 4. Improve exercise comfort. 5. Develop complimentary hardware for research and operations. Current ISS exercise hardware includes both custom and commercial-off-the-shelf (COTS) hardware. Benefits and challenges to this approach have prepared engineering teams to take a hybrid approach when designing and implementing future exercise hardware. Significant effort has gone into consideration of hardware instrumentation and wearable devices that provide important data to monitor crew health and performance

    Evidence for high levels of vertical transmission in Toxoplasma gondii

    Get PDF
    Toxoplasma gondii is a highly ubiquitous and prevalent parasite. Despite the cat being the only definitive host, it is found in almost all geographical areas and warm blooded animals. Three routes of transmission are recognised: ingestion of oocysts shed by the cat, carnivory and congenital transmission. In natural populations, it is difficult to establish the relative importance of these routes. This paper reviews recent work in our laboratory which suggests that congenital transmission may be much more important than previously thought. Using PCR detection of the parasite, studies in sheep show that congenital transmission may occur in as many as 66% of pregnancies. Furthermore, in families of sheep on the same farm, exposed to the same sources of oocysts, significant divergent prevalences of Toxoplasma infection and abortion are found between different families. The data suggest that breeding from infected ewes increases the risk of subsequent abortion and infection in lambs. Congenital transmission rates in a natural population of mice were found to be 75%. Interestingly, congenital transmission rates in humans were measured at 19.8%. The results presented in these studies differ from those of other published studies and suggest that vertical transmission may be much more important than previously thought

    Bluetooth Heart Rate Monitors For Spaceflight

    Get PDF
    Heart rate monitoring is required for crewmembers during exercise aboard the International Space Station (ISS) and will be for future exploration missions. The cardiovascular system must be sufficiently stressed throughout a mission to maintain the ability to perform nominal and contingency/emergency tasks. High quality heart rate data are required to accurately determine the intensity of exercise performed by the crewmembers and show maintenance of VO2max. The quality of the data collected on ISS is subject to multiple limitations and is insufficient to meet current requirements. PURPOSE: To evaluate the performance of commercially available Bluetooth heart rate monitors (BT_HRM) and their ability to provide high quality heart rate data to monitor crew health aboard the ISS and during future exploration missions. METHODS: Nineteen subjects completed 30 data collection sessions of various intensities on the treadmill and/or cycle. Subjects wore several BT_HRM technologies for each testing session. One electrode-based chest strap (CS) was worn, while one or more optical sensors (OS) were worn. Subjects were instrumented with a 12-lead ECG to compare the heart rate data from the Bluetooth sensors. Each BT_HRM data set was time matched to the ECG data and a +/-5bpm threshold was applied to the difference between the 2 data sets. Percent error was calculated based on the number of data points outside the threshold and the total number of data points. RESULTS: The electrode-based chest straps performed better than the optical sensors. The best performing CS was CS1 (1.6% error), followed by CS4 (3.3% error), CS3 (6.4% error), and CS2 (9.2% error). The OS resulted in 10.4% error for OS1 and 14.9% error for OS2. CONCLUSIONS: The highest quality data came from CS1, but unfortunately it has been discontinued by the manufacturer. The optical sensors have not been ruled out for use, but more investigation is needed to determine how to obtain the best quality data. CS2 will be used in an ISS Bluetooth validation study, because it simultaneously transmits magnetic pulse that is integrated with existing exercise hardware on ISS. The simultaneous data streams allow for beat-to-beat comparison between the current ISS standard and CS2. Upon Bluetooth validation aboard ISS, the research team will down select a new BT_HRM for operational use

    Planning reform, land release and the supply of housing

    Get PDF
    There is a growing interest in academic and policy circles in the relationship between land use planning policy and housing supply. Housing researchers are interested in the extent to which planning policies and practises may be exacerbating housing affordability questions, while planning academics and practitioners focus on what effect their policies actually have on the characteristics of housing supply. Policies seeking a diversity of built form are underpinned by attempts to reduce energy consumption through smaller house sizes and the design of less car dependent suburbs. Urban Growth Boundaries (UGBs) and increased net housing densities seek to slow the expansion of cities into hinterlands and reduce travel costs. The impact of UGBs on house prices is one of a number of issues that remains contested (Nelson et al 2007; Buxton and Scheurer 2007)

    Bluetooth(Registered Trademark) Heart Rate Monitors for Spaceflight

    Get PDF
    Heart rate monitoring is required during exercise for crewmembers aboard the International Space Station (ISS) and will be for future exploration missions. The cardiovascular system must be sufficiently stressed throughout a mission to maintain the ability to perform nominal and contingency/emergency tasks. High quality heart rate data is required to accurately determine the intensity of exercise performed by the crewmembers and show maintenance of VO2max. The quality of the data collected on ISS is subject to multiple limitations and is insufficient to meet current requirements. PURPOSE: To evaluate the performance of commercially available Bluetooth heart rate monitors (BT_HRM) and their ability to provide high quality heart rate data to monitor crew health on board ISS and during future exploration missions. METHODS: Nineteen subjects completed 30 data collection sessions of various intensities on the treadmill and/or cycle. Subjects wore several BT_HRM technologies for each testing session. One electrode-based chest strap (CS) was worn, while one or more optical sensors (OS) was worn. Subjects were instrumented with a 12-lead ECG to compare the heart rate data from the Bluetooth sensors. Each BT_RHM data set was time matched to the ECG data and a +/-5bpm threshold was applied to the difference between the two data sets. Percent error was calculated based on the number of data points outside the threshold and the total number of data points. REULTS: The electrode-based chest straps performed better than the optical sensors. The best performing CS was CS1 (1.6%error), followed by CS4 (3.3%error), CS3 (6.4%error), and CS2 (9.2%error). The OS resulted in 10.4% error for OS1 and 14.9% error for OS2. CONCLUSIONS: The highest quality data came from CS1, unfortunately it has been discontinued by the manufacturer. The optical sensors have not been ruled out for use, but more investigation is needed to determine how to get the best quality data. CS2 will be used in an ISS Bluetooth validation study, because it simultaneously transmits Magnetic Pulse which is integrated with existing exercise hardware on ISS. The simultaneous data streams allow for beat to beat comparison between the current ISS standard and CS2.Upon Bluetooth(Registered Trademark) validation aboard ISS, down select of a new BT_HRM for operational use will be made

    Multi-Wavelength Coverage of State Transitions in the New Black Hole X-Ray Binary Swift J1910.2-0546

    Get PDF
    Understanding how black holes accrete and supply feedback to their environment is one of the outstanding challenges of modern astrophysics. Swift J1910.2-0546 is a candidate black hole low-mass X-ray binary that was discovered in 2012 when it entered an accretion outburst. To investigate the binary configuration and the accretion morphology we monitored the evolution of the outburst for ~3 months at X-ray, UV, optical (B,V,R,I), and near-infrared (J,H,K) wavelengths using Swift and SMARTS. The source evolved from a hard to a soft X-ray spectral state with a relatively cold accretion disk that peaked at ~0.5 keV. A Chandra/HETG spectrum obtained during this soft state did not reveal signatures of an ionized disk wind. Both the low disk temperature and the absence of a detectable wind could indicate that the system is viewed at relatively low inclination. The multi-wavelength light curves revealed two notable features that appear to be related to X-ray state changes. Firstly, a prominent flux decrease was observed in all wavebands ~1-2 weeks before the source entered the soft state. This dip occurred in (0.6-10 keV) X-rays ~6 days later than at longer wavelengths, which could possibly reflect the viscous time scale of the disk. Secondly, about two weeks after the source transitioned back into the hard state, the UV emission significantly increased while the X-rays steadily decayed. We discuss how these observations may reflect changes in the accretion flow morphology, perhaps related to the quenching/launch of a jet or the collapse/recovery of a hot flow.Comment: 8 pages, 5 figures, 1 table. To be published in Ap

    Local quantum phase transition in the pseudogap Anderson model: scales, scaling and quantum critical dynamics

    Full text link
    The pseudogap Anderson impurity model provides a paradigm for understanding local quantum phase transitions, in this case between generalised fermi liquid and degenerate local moment phases. Here we develop a non-perturbative local moment approach to the generic asymmetric model, encompassing all energy scales and interaction strengths and leading thereby to a rich description of the problem. We investigate in particular underlying phase boundaries, the critical behaviour of relevant low-energy scales, and single-particle dynamics embodied in the local spectrum. Particular attention is given to the resultant universal scaling behaviour of dynamics close to the transition in both the GFL and LM phases, the scale-free physics characteristic of the quantum critical point itself, and the relation between the two.Comment: 39 pages, 19 figure
    • …
    corecore