1,096 research outputs found
The Determination of Metals in Welding Fume by X-Ray-Spectrometry
Analysis of the current hygienic situation in the welding production showed that the intensification of welding processes involves the deterioration of air quality, which negatively affects the welders health. Respiratory effects seen in full-time welders have included bronchitis, airway irritation, lung function changes, and a possible increase in the incidence of lung cancer. The metal concentration in the air of the working area have been determined using the photometric method of analysis, which involves the stage of decomposition of the sample material before analysis. However, losses of the analyzed elements are possible when the sample is decomposed. The X-ray fluorescence method of analysis has the advantage of being nondestructive. The investigations shown the data of photometric determination of metals in welding aerosols is 1.5(-:)2 times lower than the results of X-ray fluorescence analysis
A Bayesian Approach to Calibrating Period-Luminosity Relations of RR Lyrae Stars in the Mid-Infrared
A Bayesian approach to calibrating period-luminosity (PL) relations has
substantial benefits over generic least-squares fits. In particular, the
Bayesian approach takes into account the full prior distribution of the model
parameters, such as the a priori distances, and refits these parameters as part
of the process of settling on the most highly-constrained final fit.
Additionally, the Bayesian approach can naturally ingest data from multiple
wavebands and simultaneously fit the parameters of PL relations for each
waveband in a procedure that constrains the parameter posterior distributions
so as to minimize the scatter of the final fits appropriately in all wavebands.
Here we describe the generalized approach to Bayesian model fitting and then
specialize to a detailed description of applying Bayesian linear model fitting
to the mid-infrared PL relations of RR Lyrae variable stars. For this example
application we quantify the improvement afforded by using a Bayesian model fit.
We also compare distances previously predicted in our example application to
recently published parallax distances measured with the Hubble Space Telescope
and find their agreement to be a vindication of our methodology. Our intent
with this article is to spread awareness of the benefits and applicability of
this Bayesian approach and encourage future PL relation investigations to
consider employing this powerful analysis method.Comment: 6 pages, 1 figure. Accepted for publication in Astrophysics & Space
Science. Following a presentation at the conference The Fundamental Cosmic
Distance Scale: State of the Art and the Gaia Perspective, Naples, May 201
Cosmological Constraints from calibrated Yonetoku and Amati relation implies Fundamental plane of Gamma-ray bursts
We consider two empirical relations using data only from the prompt emission
of Gamma-Ray Bursts (GRBs), peak energy () - peak luminosity ()
relation (so called Yonetoku relation) and -isotropic energy () relation (so called Amati relation). We first suggest the independence
of the two relations although they have been considered similar and dependent.
From this viewpoint, we compare constraints on cosmological parameters,
and , from the Yonetoku and Amati relations
calibrated by low-redshift GRBs with . We found that they are
different in 1- level, although they are still consistent in 2-
level. This and the fact that both Amati and Yonetoku relations have systematic
errors larger than statistical errors suggest the existence of a hidden
parameter of GRBs. We introduce the luminosity time defined by as a hidden parameter to obtain a generalized Yonetoku
relation as . The new relation has much smaller systematic
error, 30%, and can be regarded as "Fundamental plane" of GRBs. We show a
possible radiation model for this new relation. Finally we apply the new
relation for high-redshift GRBs with to obtain
, which is consistent with the
concordance cosmological model within 2- level.Comment: 5 pages, 6 figures, published in JCA
Effect of magnetic and non-magnetic impurities on highly anisotropic superconductivity
We generalize Abrikosov-Gor'kov solution of the problem of weakly coupled
superconductor with impurities on the case of a multiband superconductor with
arbitrary interband order parameter anisotropy, including interband sign
reversal of the order parameter. The solution is given in terms of the
effective (renormalized) coupling matrix and describes not only
suppression but also renormalization of the superconducting gap basically at
all temperatures. In many limiting cases we find analytical solutions for the
critical temperature suppression. We illustrate our results by numerical
calculations for two-band model systems.Comment: 18 pages (12pt) RevTeX, 4 postscript figure
Promoter Sequences Prediction Using Relational Association Rule Mining
In this paper we are approaching, from a computational perspective, the problem of promoter sequences prediction, an important problem within the field of bioinformatics. As the conditions for a DNA sequence to function as a promoter are not known, machine learning based classification models are still developed to approach the problem of promoter identification in the DNA. We are proposing a classification model based on relational association rules mining. Relational association rules are a particular type of association rules and describe numerical orderings between attributes that commonly occur over a data set. Our classifier is based on the discovery of relational association rules for predicting if a DNA sequence contains or not a promoter region. An experimental evaluation of the proposed model and comparison with similar existing approaches is provided. The obtained results show that our classifier overperforms the existing techniques for identifying promoter sequences, confirming the potential of our proposal
Probing bulk viscous matter-dominated models with Gamma-ray bursts
In this paper we extend the range of consistency of a constant bulk viscosity
model to redshifts up to . In this model the dark sector of the
cosmic substratum is a viscous fluid with pressure , where
is the fluid-expansion scalar and is the coefficient of bulk
viscosity. Using the sample of 59 high-redshift GRBs reported by Wei (2010), we
calibrate GRBs at low redshifts with the Union 2 sample of SNe Ia, avoiding
then the circularity problem. Testing the constant bulk viscosity model with
GRBs we found the best fit for the viscosity parameter in the
range , being so consistent with previous probes; we also
determined the deceleration parameter and the redshift of transition to
accelerated expansion. Besides we present an updated analysis of the model with
CMB5-year data and CMB7-year data, as well as with the baryon acoustic peak
BAO. From the statistics with CMB it turns out that the model does not describe
in a feasible way the far far epoch of recombination of the universe, but is in
very good concordance for epochs as far as till present.Comment: 11 pages, 3 figures, submitted to JCA
Drinking Water Salinity and Raised Blood Pressure: Evidence from a Cohort Study in Coastal Bangladesh.
BACKGROUND: Millions of coastal inhabitants in Southeast Asia have been experiencing increasing sodium concentrations in their drinking-water sources, likely partially due to climate change. High (dietary) sodium intake has convincingly been proven to increase risk of hypertension; it remains unknown, however, whether consumption of sodium in drinking water could have similar effects on health. OBJECTIVES: We present the results of a cohort study in which we assessed the effects of drinking-water sodium (DWS) on blood pressure (BP) in coastal populations in Bangladesh. METHODS: DWS, BP, and information on personal, lifestyle, and environmental factors were collected from 581 participants. We used generalized linear latent and mixed methods to model the effects of DWS on BP and assessed the associations between changes in DWS and BP when participants experienced changing sodium levels in water, switched from "conventional" ponds or tube wells to alternatives [managed aquifer recharge (MAR) and rainwater harvesting] that aimed to reduce sodium levels, or experienced a combination of these changes. RESULTS: DWS concentrations were highly associated with BP after adjustments for confounding factors. Furthermore, for each 100 mg/L reduction in sodium in drinking water, systolic/diastolic BP was lower on average by 0.95/0.57 mmHg, and odds of hypertension were lower by 14%. However, MAR did not consistently lower sodium levels. CONCLUSIONS: DWS is an important source of daily sodium intake in salinity-affected areas and is a risk factor for hypertension. Considering the likely increasing trend in coastal salinity, prompt action is required. Because MAR showed variable effects, alternative technologies for providing reliable, safe, low-sodium fresh water should be developed alongside improvements in MAR and evaluated in "real-life" salinity-affected settings. https://doi.org/10.1289/EHP659
Length of carotid stenosis predicts peri-procedural stroke or death and restenosis in patients randomized to endovascular treatment or endarterectomy.
BACKGROUND: The anatomy of carotid stenosis may influence the outcome of endovascular treatment or carotid endarterectomy. Whether anatomy favors one treatment over the other in terms of safety or efficacy has not been investigated in randomized trials.
METHODS: In 414 patients with mostly symptomatic carotid stenosis randomized to endovascular treatment (angioplasty or stenting; n = 213) or carotid endarterectomy (n = 211) in the Carotid and Vertebral Artery Transluminal Angioplasty Study (CAVATAS), the degree and length of stenosis and plaque surface irregularity were assessed on baseline intraarterial angiography. Outcome measures were stroke or death occurring between randomization and 30 days after treatment, and ipsilateral stroke and restenosis ≥50% during follow-up. RESULTS: Carotid stenosis longer than 0.65 times the common carotid artery diameter was associated with increased risk of peri-procedural stroke or death after both endovascular treatment [odds ratio 2.79 (1.17-6.65), P = 0.02] and carotid endarterectomy [2.43 (1.03-5.73), P = 0.04], and with increased long-term risk of restenosis in endovascular treatment [hazard ratio 1.68 (1.12-2.53), P = 0.01]. The excess in restenosis after endovascular treatment compared with carotid endarterectomy was significantly greater in patients with long stenosis than with short stenosis at baseline (interaction P = 0.003). Results remained significant after multivariate adjustment. No associations were found for degree of stenosis and plaque surface.
CONCLUSIONS: Increasing stenosis length is an independent risk factor for peri-procedural stroke or death in endovascular treatment and carotid endarterectomy, without favoring one treatment over the other. However, the excess restenosis rate after endovascular treatment compared with carotid endarterectomy increases with longer stenosis at baseline. Stenosis length merits further investigation in carotid revascularisation trials
Label-free electrochemical impedance biosensor to detect human interleukin-8 in serum with sub-pg/ml sensitivity
Biosensors with high sensitivity and short time-to-result that are capable of detecting biomarkers in body fluids such as serum are an important prerequisite for early diagnostics in modern healthcare provision. Here, we report the development of an electrochemical impedance-based sensor for the detection in serum of human interleukin-8 (IL-8), a pro-angiogenic chemokine implicated in a wide range of inflammatory diseases. The sensor employs a small and robust synthetic non-antibody capture protein based on a cystatin scaffold that displays high affinity for human IL-8 with a KD of 35 ± 10 nM and excellent ligand specificity. The change in the phase of the electrochemical impedance from the serum baseline, ∆θ(ƒ), measured at 0.1 Hz, was used as the measure for quantifying IL-8 concentration in the fluid. Optimal sensor signal was observed after 15 min incubation, and the sensor exhibited a linear response versus logarithm of IL-8 concentration from 900 fg/ml to 900 ng/ml. A detection limit of around 90 fg/ml, which is significantly lower than the basal clinical levels of 5-10 pg/ml, was observed. Our results are significant for the development of point-of-care and early diagnostics where high sensitivity and short time-to-results are essential
- …