2,656 research outputs found

    Towards measurement and verification of energy performance under the framework of the European directive for energy performance of buildings

    Get PDF
    Directive 2002/91/EC of the European Parliament and Council on the Energy Performance of Buildings has led to major developments in energy policies followed by the EU Member States. The national energy performance targets for the built environment are mostly rooted in the Building Regulations that are shaped by this Directive. Article 3 of this Directive requires a methodology to calculate energy performance of buildings under standardised operating conditions. Overwhelming evidence suggests that actual energy performance is often significantly higher than this standardised and theoretical performance. The risk is national energy saving targets may not be achieved in practice. The UK evidence for the education and office sectors is presented in this paper. A measurement and verification plan is proposed to compare actual energy performance of a building with its theoretical performance using calibrated thermal modelling. Consequently, the intended vs. actual energy performance can be established under identical operating conditions. This can help identify the shortcomings of construction process and building procurement. Once energy performance gap is determined with reasonable accuracy and root causes identified, effective measures could be adopted to remedy or offset this gap

    Using temporal distributions of transient events to characterize cosmological source populations

    Full text link
    The brightest events in a time series of cosmological transients obey an observation time dependence which is often overlooked. This dependence can be exploited to probe the global properties of electromagnetic and gravitational wave transients (Howell et al. 2007a, Coward & Burman 2005). We describe a new relation based on a peak flux--observation time distribution and show that it is invariant to the luminosity distribution of the sources (Howell et al. 2007b). Applying this relation, in combination with a new data analysis filter, to \emph{Swift} gamma-ray burst data, we demonstrate that it can constrain their rate density.Comment: published in proceedings of FRONTIERS OF FUNDAMENTAL AND COMPUTATIONAL PHYSICS: 10th International Symposium, AIP,1246,203, (2010

    An improved method for estimating source densities using the temporal distribution of Cosmological Transients

    Full text link
    It has been shown that the observed temporal distribution of transient events in the cosmos can be used to constrain their rate density. Here we show that the peak flux--observation time relation takes the form of a power law that is invariant to the luminosity distribution of the sources, and that the method can be greatly improved by invoking time reversal invariance and the temporal cosmological principle. We demonstrate how the method can be used to constrain distributions of transient events, by applying it to Swift gamma-ray burst data and show that the peak flux--observation time relation is in good agreement with recent estimates of source parameters. We additionally show that the intrinsic time dependence allows the method to be used as a predictive tool. Within the next year of Swift observation, we find a 50% chance of obtaining a peak flux greater than that of GRB 060017 -- the highest Swift peak flux to date -- and the same probability of detecting a burst with peak flux > 100 photons s^{-1} cm^{-2} within 6 years.Comment: Submitted to ApJ Letter

    A comparative study of benchmarking approaches for non-domestic buildings: Part 1 ā€“ Top-down approach

    Get PDF
    Benchmarking plays an important role in improving energy efficiency of non-domestic buildings. A review of energy benchmarks that underpin the UKā€™s Display Energy Certificate (DEC) scheme have prompted necessities to explore the benefits and limitations of using various methods to derive energy benchmarks. The existing methods were reviewed and grouped into top-down and bottom-up approaches based on the granularity of the data used. In the study, two top-down methods, descriptive statistics and artificial neural networks (ANN), were explored for the purpose of benchmarking energy performances of schools. The results were used to understand the benefits of using these benchmarks for assessing energy efficiency of buildings and the limitations that affect the robustness of the derived benchmarks. Compared to the bottom-up approach, top-down approaches were found to be beneficial in gaining insight into how peers perform. The relative rather than absolute feedback on energy efficiency meant that peer pressure was a motivator for improvement. On the other hand, there were limitations with regard to the extent to which the energy efficiency of a building could be accurately assessed using the top-down benchmarks. Moreover, difficulties in acquiring adequate data were identified as a key limitation to using the top-down approach for benchmarking non-domestic buildings. The study suggested that there are benefits in rolling out of DECs to private sector buildings and that there is a need to explore more complex methods to provide more accurate indication of energy efficiency in non-domestic buildings

    Building Schools for the Future: Lessons Learned From Performance Evaluations of Five Secondary Schools and Academies in England

    Get PDF
    Building performance evaluations (BPE) of five secondary schools and academies constructed under the Building Schools for the Future (BSF) programme in England found that CO2 emissions associated with operational energy performance in all these buildings is higher than the median of the secondary schools. Whilst the new regulatory requirements for building fabric performance have led to some improvements in heating energy when compared against good practice and typical benchmarks, there is still significant discrepancy between heating energy use and the design expectations. Electricity use in these buildings is also 37ā€“191% more than the median school and significantly worse than the design expectations. These results point to the importance of post-occupancy building fine-tuning and measurement and verification of performance in-use with respect to design projections to narrow the performance gap. It is also necessary to set out clear operational performance targets and protect energy efficiency measures from value engineering throughout building procurement and in operation to achieve good level of performance. Finally, it is suggested to adopt a holistic view of energy, environmental quality, and educational performance to have a better understanding of schools' performance and potential conflicts between energy efficiency measures and indoor environmental quality (IEQ)

    Managing the risk of the energy performance gap in non-domestic buildings

    Get PDF
    Energy use in buildings accounts for one-third of the overall global energy consumption and total building floor area continues to increase each year as new developments are constructed and delivered. If stringent climate goals are to be met, these buildings will need to consume less energy and emit less carbon. However, design intentions for energy efficient buildings are not always met in practice. This performance gap between calculated and measured energy use in buildings threatens the progress necessary to meet these energy targets. The aim of this paper is to identify the factors that contribute to the performance gap and propose solutions for reducing the gap in practice. A quantitative and qualitative analysis of two research programmes completed in the past few years was utilized for an in-depth look at the performance of around 50 non-domestic buildings in the United Kingdom. While no direct links were found between any one variable and the performance gap, several correlations exist between contributing factors indicating a complex, entangled web of interrelated problems. The multitude of the variables involved presents a formidable challenge in finding practical solutions. However, the results indicate that the combination of the ventilation strategy of a building and the building services control strategy during partial occupancy is a key determinant of the performance gap. A more straightforward procurement approach with clearly delineated targets and responsibilities, along with advanced and seasonal commissioning instituted at the beginning of a project and implemented after building completion can also be very effective in reducing the gap. Finally, mandatory requirements or an appropriate system of incentives for monitoring and disclosure of performance data can help identify many of the underlying issues affecting performance in-use and untangle some of the web of complex issues across the building sector

    Is there a link between treatments with exogenous corticosteroids and dog behaviour problems?

    Get PDF
    Possible side effects of exogenous corticosteroids have been described in both humans and laboratory animals, with recent studies highlighting this issue in dogs. In this paper the behaviour of 345 dogs drawn from the caseload of a behaviour clinic based in the north of Italy between February 2012 and November 2014 were analysed. Possible relationships between dogs that received treatment with corticosteroids versus dogs that received treatment with drugs other than corticosteroids and positive or negative affective states, aggression towards people, other behaviour problems apart from aggression, occurrence of severe bites, and prescription of psychoactive drugs were initially assessed using a Pearson's chi-squared test. Regression analysis was then performed in order to evaluate the best predictors of the investigated items. The goal of this retrospective survey was to investigate possible relationships between the affective states associated with the behavioural complaint of dogs and their previous history of treatment with corticosteroids. Results showed that a history of corticosteroid treatment was a significant predictor of a range of behaviour problems associated with negative affective state, but this result may be confounded by age-related effects