260 research outputs found

    Information Literacy: Time for a Comprehensive Plan

    Get PDF
    Press release from the American Library Association announcing pre-conference, Information Literacy: Time for a Comprehensive Plan, to be held at the 2004 ALA Conference in Orlando, Florida on July 25, 2004. Using a workbook created by the preconference presenters, participants will be guided through the process of creating a comprehensive information literacy plan, and will learn how to identify and apply essential elements in constructing a successful long-term plan. Participants will leave the session with an outline and draft plan for their home institutions

    Interventional closure of RPA-to-LA communication in an oligosymptomatic neonate

    Full text link
    Direct communication between the right pulmonary artery (RPA) and the left atrium (LA) is a very rare cardiac malformation. Clinical presentation of RPA-to-LA communication depends on the size of the communication, the amount of right-to-left shunt, the patient’s age, and pulmonary vascular resistance. Patients with small communications usually present oligosymptomatic and are diagnosed at an older age. A delay of diagnosis bears the risk of severe complications and needs to be prevented by proper work-up of oligosymptomatic neonates. Treatment of RPA-to-LA communications used to be performed by surgical closure, and the interventional approach has only been established as a less invasive alternative in recent years. Conclusion: Although patients with small RPA-to-LA communications usually present oligosymptomatic, early diagnosis and treatment is essential to prevent life-threatening complications

    Flow evaluation software for four-dimensional flow MRI: a reliability and validation study

    Full text link
    PURPOSE Four-dimensional time-resolved phase-contrast cardiovascular magnetic resonance imaging (4D flow MRI) enables blood flow quantification in multiple vessels, which is crucial for patients with congenital heart disease (CHD). We investigated net flow volumes in the ascending aorta and pulmonary arteries by four different postprocessing software packages for 4D flow MRI in comparison with 2D cine phase-contrast measurements (2D PC). MATERIAL AND METHODS 4D flow and 2D PC datasets of 47 patients with biventricular CHD (median age 16, range 0.6-52 years) were acquired at 1.5 T. Net flow volumes in the ascending aorta, the main, right, and left pulmonary arteries were measured using four different postprocessing software applications and compared to offset-corrected 2D PC data. Reliability of 4D flow postprocessing software was assessed by Bland-Altman analysis and intraclass correlation coefficient (ICC). Linear regression of internal flow controls was calculated. Interobserver reproducibility was evaluated in 25 patients. RESULTS Correlation and agreement of flow volumes were very good for all software compared to 2D PC (ICC ≥ 0.94; bias ≤ 5%). Internal controls were excellent for 2D PC (r ≥ 0.95, p < 0.001) and 4D flow (r ≥ 0.94, p < 0.001) without significant difference of correlation coefficients between methods. Interobserver reliability was good for all vendors (ICC ≥ 0.94, agreement bias < 8%). CONCLUSION Haemodynamic information from 4D flow in the large thoracic arteries assessed by four commercially available postprocessing applications matches routinely performed 2D PC values. Therefore, we consider 4D flow MRI-derived data ready for clinical use in patients with CHD

    Physical Activity in Fontan Patients Relates to Quality of Life and Sleep Quality

    Full text link
    Background and Aim: Fontan patients tend to have reduced physical exercise capacity. This study investigates physical activity (PA) and its relationship to exercise capacity, heart rates, cardiac function, biomarkers, health-related quality of life (HRQoL), and sleep quality. Methods: Cardiovascular magnetic resonance (CMR), exercise testing (CPET), 24 h-ECG, and blood samples were prospectively performed in 38 patients, age 13 (11-16) years. PA was assessed by accelerometer during 7 consecutive days. HRQoL was self-assessed with KIDSCREEN-27 and SF-36 according to patients' age; sleep quality with Pediatric Sleep Questionnaire (PSQ) and Pittsburgh Sleep Quality Index (PSQI). Results: Daily moderate to vigorous physical activity (MVPA) was in median (IQR) 40 (28-57) mins; 7/38 (18%) patients reached the recommended 60 mins/day of MVPA. MVPA did not correlate with gender, age, single ventricle morphology, time from Fontan, heart rate, ventricular volumes, and ejection fraction at CMR, biomarkers, or CPET. Physical wellbeing (r = 0.33, p = 0.04), autonomy (r = 0.39, p = 0.03), and social support (r = 0.43, p = 0.009) assessed using the KIDSCREEN-27, and both physical (r = 0.57, p = 0.03) and mental (r = 0.54, p = 0.04) domains of the SF-36 questionnaire correlated with daily minutes of MVPA. PSQI global sleeping score (r = -0.7, p = 0.007), and PSQ scales for behavior (r = -0.36; p = 0.03) correlated with daily minutes of MVPA. Conclusion: Only 18% of the Fontan patients meet the recommendation for daily MVPA. Measures of exercise capacity, cardiac function or chronotropic competence are not correlated to daily physical activity. In contrast, HRQoL and sleep quality seem to be associated with regular physical activity

    Signal Thresholding Segmentation of Ventricular Volumes in Young Patients with Various Diseases—Can We Trust the Numbers?

    Full text link
    In many cardiac diseases, right and left ventricular volumes in systole and diastole are diagnostically and prognostically relevant. Measurements are made by segmentation of the myocardial borders on cardiac magnetic resonance (CMR) images. Automatic detection of myocardial contours is possible by signal thresholding techniques, but must be validated before use in clinical settings. Biventricular volumes were measured in end-diastole (EDVi) and in end-systole (ESVi) both manually and with the MassK application, with signal thresholds at 30%, 50%, and 70%. Stroke volumes (SV) and cardiac indices (CI) were calculated from volumetric measurements and from flow measured in the ascending aorta and the main pulmonary artery, and both methods were compared. Reproducibility of volumetric measurements was tested in 20 patients. Measurements were acquired in 94 patients aged 15 ± 9 years referred for various conditions. EDVi and ESVi of both ventricles were largest with manual segmentation and inversely proportional to the MassK threshold. Manual and k30 SV and CI corresponded best to flow measurements. Interobserver variability was low for all volumes manually and with MassK. In conclusion, manual and 30% threshold-based biventricular volume segmentation agree best with two-dimensional, phantom-corrected phase contrast flow measurements in a young cardiac referral population and are well reproducible

    Quantitative evaluation of aortic valve regurgitation in 4D flow cardiac magnetic resonance: at which level should we measure?

    Full text link
    PURPOSE To find the best level to measure aortic flow for quantification of aortic regurgitation (AR) in 4D flow CMR. METHODS In 27 congenital heart disease patients with AR (67% male, 31 ± 16 years) two blinded observers measured antegrade, retrograde, net aortic flow volumes and regurgitant fractions at 6 levels in 4D flow: (1) below the aortic valve (AV), (2) at the AV, (3) at the aortic sinus, (4) at the sinotubular junction, (5) at the level of the pulmonary arteries (PA) and (6) below the brachiocephalic trunk. 2D phase contrast (2DPC) sequences were acquired at the level of PA. All patients received prior transthoracic echocardiography (TTE) with AR severity grading according to a recommended multiparametric approach. RESULTS After assigning 2DPC measurements into AR grading, agreement between TTE AR grading and 2DPC was good (κ = 0.88). In 4D flow, antegrade flow was similar between the six levels (p = 0.87). Net flow was higher at level 1-2 than at levels 3-6 (p < 0.05). Retrograde flow and regurgitant fraction at level 1-2 were lower compared to levels 3-6 (p < 0.05). Reproducibility (inter-reader agreement: ICC 0.993, 95% CI 0.986-0.99; intra-reader agreement: ICC 0.982, 95%CI 0.943-0.994) as well as measurement agreement between 4D flow and 2DPC (ICC 0.994; 95%CI 0.989 - 0.998) was best at the level of PA. CONCLUSION For estimating severity of AR in 4D flow, best reproducibility along with best agreement with 2DPC measurements can be expected at the level of PA. Measurements at AV or below AV might underestimate AR

    Myocardial Deformation in Fontan Patients Assessed by Cardiac Magnetic Resonance Feature Tracking: Correlation with Function, Clinical Course, and Biomarkers

    Full text link
    Cardiac MR (CMR) is a standard modality for assessing ventricular function of single ventricles. CMR feature-tracking (CMR-FT) is a novel application enabling strain measurement on cine MR images and is used in patients with congenital heart diseases. We sought to assess the feasibility of CMR-FT in Fontan patients and analyze the correlation between CMR-FT strain values and conventional CMR volumetric parameters, clinical findings, and biomarkers. Global circumferential (GCS) and longitudinal (GLS) strain were retrospectively measured by CMR-FT on Steady-State Free Precession cine images. Data regarding post-operative course at Fontan operation, and medication, exercise capacity, invasive hemodynamics, and blood biomarkers at a time interval ± 6 months from CMR were collected. Forty-seven patients underwent CMR 11 ± 6 years after the Fontan operation; age at CMR was 15 ± 7 years. End-diastolic volume (EDV) of the SV was 93 ± 37 ml/m2, end-systolic volume (ESV) was 46 ± 23 ml/m2, and ejection fraction (EF) was 51 ± 11%. Twenty (42%) patients had a single right ventricle (SRV). In single left ventricle (SLV), GCS was higher (p < 0.001), but GLS was lower (p = 0.04) than in SRV. GCS correlated positively with EDV (p = 0.005), ESV (p < 0.001), and EF (p ≤ 0.0001). GLS correlated positively with EF (p = 0.002), but not with ventricular volumes. Impaired GCS correlated with decreased ventricular function (p = 0.03) and atrioventricular valve regurgitation (p = 0.04) at echocardiography, direct atriopulmonary connection (p = 0.02), post-operative complications (p = 0.05), and presence of a rudimentary ventricle (p = 0.01). A reduced GCS was associated with increased NT-pro-BNP (p = 0.05). Myocardial deformation can be measured by CMR-FT in Fontan patients. SLVs have higher GCS, but lower GLS than SRVs. GCS correlates with ventricular volumes and EF, whereas GLS correlates with EF only. Myocardial deformation shows a relationship with several clinical parameters and NT-pro-BNP. Keywords: Biomarkers; CMR; CMR-FT; Fontan; Strai

    ICON in Climate Limited-area Mode (ICON release version 2.6.1): a new regional climate model

    Get PDF
    For the first time, the Limited-Area Mode of the new ICON (Icosahedral Nonhydrostatic) weather and climate model has been used for a continuous long-term regional climate simulation over Europe. Built upon the Limited-Area Mode of ICON (ICON-LAM), ICON-CLM (ICON in Climate Limited-area Mode, hereafter ICON-CLM, available in ICON release version 2.6.1) is an adaptation for climate applications. A first version of ICON-CLM is now available and has already been integrated into a starter package (ICON-CLM_SP_betal). The starter package provides users with a technical infrastructure that facilitates long-term simulations as well as model evaluation and test routines. ICON-CLM and ICON-CLM_SP were successfully installed and tested on two different computing systems. Tests with different domain decompositions showed bit-identical results, and no systematic outstanding differences were found in the results with different model time steps. ICON-CLM was also able to reproduce the large-scale atmospheric information from the global driving model. Comparison was done between ICON-CLM and the COnsortium for Small-scale MOdeling (COSMO)-CLM (the recommended model configuration by the CLM-Community) performance. For that, an evaluation run of ICON-CLM with ERA-Interim boundary conditions was carried out with the setup similar to the COSMO-CLM recommended optimal setup. ICON-CLM results showed biases in the same range as those of COSMO-CLM for all evaluated surface variables. While this COSMO-CLM simulation was carried out with the latest model version which has been developed and was carefully tuned for climate simulations on the European domain, ICON-CLM was not tuned yet. Nevertheless, ICON-CLM showed a better performance for air temperature and its daily extremes, and slightly better performance for total cloud cover. For precipitation and mean sea level pressure, COSMO-CLM was closer to observations than ICON-CLM. However, as ICON-CLM is still in the early stage of development, there is still much room for improvement
    • …
    corecore