51 research outputs found

    A new metrological characterization strategy for 3D multi-camera systems

    Get PDF
    AbstractThe objective of this study is to establish a new methodology for the metrological characterization of interactive multi-camera systems. In the case of 3D system highly adapted to specific needs the accuracy evaluation cannot be performed using standard state-of-the-art techniques. To this end, the metrological characterization techniques used in the literature were investigated in order to define a new methodology that can be adjusted to each device by making the appropriate modifications. The proposed strategy is adopted for the metrological characterization of a new interactive multi-camera system for the acquisition of the arm

    Reverse Engineering of Mechanical Parts: a Template-Based Approach

    Get PDF
    Abstract Template-Based reverse engineering approaches represent a relatively poorly explored strategy in the field of CAD reconstruction from polygonal models. Inspired by recent works suggesting the possibility/opportunity of exploiting a parametric description (i.e. CAD template) of the object to be reconstructed in order to retrieve a meaningful digital representation, a novel reverse engineering approach for the reconstruction of CAD models starting from 3D mesh data is proposed. The reconstruction process is performed relying on a CAD template, whose feature tree and geometric constraints are defined according to the a priori information on the physical object. The CAD template is fitted upon the mesh data, optimizing its dimensional parameters and positioning/orientation by means of a particle swarm optimization algorithm. As a result, a parametric CAD model that perfectly fulfils the imposed geometric relations is produced and a feature tree, defining an associative modelling history, is available to the reverse engineer. The proposed implementation exploits a cooperation between a CAD software package (Siemens NX) and a numerical software environment (MATLAB). Five reconstruction tests, covering both synthetic and real-scanned mesh data, are presented and discussed in the manuscript; the results are finally compared with models generated by state of the art reverse engineering software and key aspects to be addressed in future work are hinted at. Highlights A novel CAD reconstruction method fitting a CAD template model to mesh data. A feature-based parametric-associative modelling history is retrieved. Fitting process is controlled by a Particle Swarm Optimization algorithm. Accuracy of reconstructed models is comparable/better than state of the art results. Computational costs and required time are at the moment considerable

    A Fast and Reliable Optical 3D Scanning System for Human Arm

    Get PDF
    AbstractThe article discusses the design of an acquisition system for the 3D surface of human arms. The system is composed by a 3D optical scanner implementing stereoscopic depth sensors and by an acquisition software responsible for the processing of the raw data. The 3D data acquired by the scanner is used as starting point for the manufacturing of custom-made 3D printed casts. Specifically, the article discusses the choices made in the development of an improved version of an existing system presented in [1] and presents the results achieved by the devised system

    Progression of echocardiographic parameters and prognosis in transthyretin cardiac amyloidosis

    Get PDF
    Aims: Transthyretin amyloid cardiomyopathy (ATTR-CM) is an increasingly diagnosed disease. Echocardiography is widely utilized, but studies to confirm the value of echocardiography for tracking changes over time are not available. We sought to describe (i) changes in multiple echocardiographic parameters; (ii) differences in rate of progression of three predominant genotypes; and (iii) the ability of changes in echocardiographic parameters to predict prognosis. Methods and results: We prospectively studied 877 ATTR-CM patients attending our centre between 2000 and 2020. Serial echocardiography findings at baseline, 12 months and 24 months were compared with survival. Overall, 565 patients had wild-type ATTR-CM and 312 hereditary ATTR-CM (201 with V122I; 90 with T60A). There was progressive worsening of structural and functional parameters over time, patients with V122I ATTR-CM showing more rapid worsening of left and right ventricular structural and functional parameters compared to both wild-type and T60A ATTR-CM. Among a wide range of echocardiographic analyses, including deformation-based parameters, only worsening in the degree of mitral (MR) and tricuspid regurgitation (TR) at 12- and 24-month assessments was associated with worse prognosis (change at 12 months: MR, hazard ratio 1.43 [95% confidence interval 1.14–1.80], p = 0.002; TR, hazard ratio 1.38 [95% confidence interval 1.10–1.75], p = 0.006). Worsening in MR remained independently associated with poor prognosis after adjusting for known predictors. Conclusion: In ATTR-CM, echocardiographic parameters progressively worsen over time. Patients with V122I ATTR-CM demonstrate the most rapid deterioration. Worsening of MR and TR were the only parameters associated with mortality, MR remaining independent after adjusting for known predictors
    • …
    corecore