2,935 research outputs found

    Closed loop ranging system Patent

    Get PDF
    Closed loop radio communication ranging system to determine distance between moving airborne vehicle and fixed ground statio

    Automatic carrier acquisition system for phase-lock-loop receivers

    Get PDF
    Programmable oscillator and zero-beat detector acquires phase-lock of carrier by frequency scanning. Generation of high-level dc pulse at instant of zero crossing provides positive trigger for decision gate to stop search and close loop for phase-coherent tracking

    Automatic carrier acquisition system

    Get PDF
    An automatic carrier acquisition system for a phase locked loop (PLL) receiver is disclosed. It includes a local oscillator, which sweeps the receiver to tune across the carrier frequency uncertainty range until the carrier crosses the receiver IF reference. Such crossing is detected by an automatic acquisition detector. It receives the IF signal from the receiver as well as the IF reference. It includes a pair of multipliers which multiply the IF signal with the IF reference in phase and in quadrature. The outputs of the multipliers are filtered through bandpass filters and power detected. The output of the power detector has a signal dc component which is optimized with respect to the noise dc level by the selection of the time constants of the filters as a function of the sweep rate of the local oscillator

    TRISCAN: A method of precision antenna positioning

    Get PDF
    The triangle (antenna) scan (TRISCAN) is a method of improving the alignment between the boresight of the Deep Space Network antennas and a particular target, spacecraft, or radio source (star). For stars, the method works in conjunction with the noise adding radiometer and the antenna pointing system to form estimates of the alignment offset coordinates. This information is then used to position the antenna for improved target alignment. A comparison with CONSCAN is included since a CONSCAN study led to TRISCAN development

    The farmer looks at soil conservation in southern Iowa

    Get PDF
    Over 90 percent of the farmers cooperating with the Soil Conservation Service who were interviewed in this study reported that the program had reduced sheet and gully erosion; 55 percent stated that sheet erosion had been greatly reduced or stopped, while almost 70 percent reported that gully erosion had been greatly reduced or stopped

    Inferring Kangaroo Phylogeny from Incongruent Nuclear and Mitochondrial Genes

    Get PDF
    The marsupial genus Macropus includes three subgenera, the familiar large grazing kangaroos and wallaroos of M. (Macropus) and M. (Osphranter), as well as the smaller mixed grazing/browsing wallabies of M. (Notamacropus). A recent study of five concatenated nuclear genes recommended subsuming the predominantly browsing Wallabia bicolor (swamp wallaby) into Macropus. To further examine this proposal we sequenced partial mitochondrial genomes for kangaroos and wallabies. These sequences strongly favour the morphological placement of W. bicolor as sister to Macropus, although place M. irma (black-gloved wallaby) within M. (Osphranter) rather than as expected, with M. (Notamacropus). Species tree estimation from separately analysed mitochondrial and nuclear genes favours retaining Macropus and Wallabia as separate genera. A simulation study finds that incomplete lineage sorting among nuclear genes is a plausible explanation for incongruence with the mitochondrial placement of W. bicolor, while mitochondrial introgression from a wallaroo into M. irma is the deepest such event identified in marsupials. Similar such coalescent simulations for interpreting gene tree conflicts will increase in both relevance and statistical power as species-level phylogenetics enters the genomic age. Ecological considerations in turn, hint at a role for selection in accelerating the fixation of introgressed or incompletely sorted loci. More generally the inclusion of the mitochondrial sequences substantially enhanced phylogenetic resolution. However, we caution that the evolutionary dynamics that enhance mitochondria as speciation indicators in the presence of incomplete lineage sorting may also render them especially susceptible to introgression.This work has been supported by Australian Research Council grants to MJP (DP07745015) and MB (FT0991741). The website for the funder is www.arc.gov.au. The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript

    A phase III, multi-centre, double-masked randomised controlled trial of adjunctive intraocular and peri-ocular steroid (triamcinolone acetonide) versus standard treatment in eyes undergoing vitreoretinal surgery for open globe trauma (ASCOT): statistical analysis plan.

    Get PDF
    BACKGROUND: Open globe ocular trauma complicated by intraocular scarring (proliferative vitreoretinopathy) is a relatively rare, blinding, but potentially treatable condition for which, at present, surgery is often unsatisfactory and visual results frequently poor. To date, no pharmacological adjuncts to surgery have been proven to be effective. The aim of the Adjunctive Steroid Combination in Ocular Trauma (ASCOT) randomised controlled trial is to determine whether adjunctive steroid (triamcinolone acetonide), given at the time of surgery, can improve the outcome of vitreoretinal surgery in patients with open globe ocular trauma. This article presents the statistical analysis plan for the main publication as approved and signed off by the Trial Steering Committee prior to the first data extraction for the Data Monitoring Committee meeting report. METHODS/DESIGN: ASCOT is a pragmatic, multi-centre, parallel-group, double-masked randomised controlled trial. The aim of the study is to recruit from 20-25 centres in the United Kingdom and randomise 300 eyes (from 300 patients) into two treatment arms. Both groups will receive standard surgical treatment and care; the intervention arm will additionally receive a pre-operative steroid combination (triamcinolone acetonide) into the vitreous cavity consisting of 4 mg/0.1 ml and 40 mg/1 ml sub-Tenon's. Participants will be followed for 6 months post-surgery. The primary outcome is the proportion of patients achieving a clinically meaning improvement in visual acuity in the study eye at 6 months after initial surgery, defined as a 10 letter score improvement in the ETDRS (the standard scale to test visual acuity). TRIAL REGISTRATION: ISRCTN30012492 . Registered on 5 September 2014. EudraCT2014-002193-37 . Registered on 5 September 2014

    Unified S-band receiver-exciter subsystem

    Get PDF
    Functional capabilities and physical arrangement of receiver exciter subsystem in unified S band Apollo communications and tracking ground station syste

    Ozurdex(R) (a slow-release dexamethasone implant) in proliferative vitreoretinopathy: study protocol for a randomised controlled trial

    Get PDF
    Proliferative vitreoretinopathy (PVR) is the commonest cause of late anatomical failure in rhegmatogenous retinal detachment. Visual and anatomical outcomes remain poor despite advances in vitreoretinal surgical techniques with reported primary failure rates of up to nearly 50%. Numerous adjunctive medications have been evaluated in clinical trials with no agent gaining widespread acceptance and use.This study was designed to investigate the benefits of using a slow-release dexamethasone implant delivered intra-operatively in patients undergoing vitrectomy surgery for retinal detachment with established PVR.Methods/design: For the study, 140 patients requiring vitrectomy surgery with silicone oil for retinal detachment with established PVR will be randomised to receive either standard treatment or study treatment in a 1:1 treatment allocation ratio. Both groups will receive the standard surgical treatment appropriate for their eye condition and routine peri-operative treatment and care, differing only in the addition of the supplementary adjunctive agent in the treatment group. The investigated primary outcome measure is stable retinal reattachment with removal of silicone oil without additional vitreoretinal surgical intervention at 6 months
    • …
    corecore