32 research outputs found

    Accuracy of needle biopsy of breast lesions visible on ultrasound: audit of fine needle versus core needle biopsy in 3233 consecutive samplings with ascertained outcomes.

    Get PDF
    Abstract Introduction Core needle biopsy (CNB) has progressively replaced fine needle aspiration cytology (FNAC) in the diagnosis of breast lesions. Less information is available on how these tests perform for biopsy of ultrasound (US) visible breast lesions. This study examines the outcomes of CNB and FNAC in a large series ascertained with surgical histology or clinical-imaging follow-up. Materials and methods Retrospective five-year audit of 3233 consecutive US-guided needle samplings of solid breast lesions, from self-referred symptomatic or asymptomatic subjects, performed by six radiologists in the same time-frame (2003–2006): 1950 FNAC and 1283 CNB. The probability of undergoing CNB as a first test instead of FNAC was evaluated using logistic regression. Accuracy and inadequacy were calculated for each of CNB and FNAC performed as first test. Accuracy measures included equivocal or borderline/atypical lesions as positive results. Results The probability of CNB as a first test instead of FNAC increased significantly over time, when there was a pre-test higher level of suspicion, in younger (relative to older) women, with increasing lesion size on imaging, and for palpable (relative to impalpable) lesions. Inadequacy rate was lower for CNB (B1 = 6.9%) than for FNAC (C1 = 17.7%), p vs . C1 = 4.5%; p vs . 74.4%; p vs . 93.8%; p = 0.001), however specificity was lower for CNB than FNAC (88.3% vs . 96.4%; p vs . 71.9; p complete diagnostic accuracy (95.4% vs . 93.2; p Conclusion FNAC and CNB were generally performed in different patients, thus our study reported indirect comparisons of these tests. Although FNAC performed well (except for relatively high inadequacy), CNB had significantly better performance based on measures of sensitivity, but this was associated with lower specificity for CNB relative to FNAC. Overall, CNB is the more reliable biopsy method for sonographically-visible lesions; where FNAC is used as the first-line test, inadequate or inconclusive FNAC can be largely resolved by using repeat sampling with CNB

    The accuracy of frozen section analysis in ultrasound- guided core needle biopsy of breast lesions

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Limited data are available to evaluate the accuracy of frozen section analysis and ultrasound- guided core needle biopsy of the breast.</p> <p>Methods</p> <p>In a retrospective analysis data of 120 consecutive handheldultrasound- guided 14- gauge automated core needle biopsies (CNB) in 109 consecutive patients with breast lesions between 2006 and 2007 were evaluated.</p> <p>Results</p> <p>In our outpatient clinic120 CNB were performed. In 59/120 (49.2%) cases we compared histological diagnosis on frozen sections with those on paraffin sections of CNB and finally with the result of open biopsy. Of the cases 42/59 (71.2%) were proved to be malignant and 17/59 (28.8%) to be benign in the definitive histology. 2/59 (3.3%) biopsies had a false negative frozen section result. No false positive results of the intraoperative frozen section analysis were obtained, resulting in a sensitivity, specificity and positive predicting value (PPV) and negative predicting value (NPV) of 95%, 100%, 100% and 90%, respectively. Histological and morphobiological parameters did not show up relevance for correct frozen section analysis. In cases of malignancy time between diagnosis and definitive treatment could not be reduced due to frozen section analysis.</p> <p>Conclusion</p> <p>The frozen section analysis of suspect breast lesions performed by CNB displays good sensitivity/specificity characteristics. Immediate investigations of CNB is an accurate diagnostic tool and an important step in reducing psychological strain by minimizing the period of uncertainty in patients with breast tumor.</p

    Early detection of breast, cervical, ovarian and endometrial cancers in low resource countries: an integrated approach

    Get PDF
    The incidence of breast and gynecological cancers continues to increase in low and middle resource countries [LRC'S and MRC's] with a disproportionately higher mortality rate compared to that in high resource countries. This has been attributed to factors such as an increased life span due to better control of communicable diseases and improved nutrition, as well as lifestyle and reproductive changes. A lack of public awareness and understanding of these cancers, absence of an organized screening program and a lack of accessible and effective treatment options, is responsible for the higher mortality rate. A practical approach of a combined program of integrating a well woman examination with screening for breast and cervical cancer and diagnostic evaluation for Ovarian and Endometrial cancer in symptomatic women is proposed in this article which can serve as a model to be studied for efficacy in low resource countries

    Borderline breast core needle histology: predictive values for malignancy in lesions of uncertain malignant potential (B3)

    Get PDF
    Breast core needle biopsy (CNB) is an accurate test but may result in borderline histology (lesions of uncertain malignant potential or B3). This is an evaluation of the largest series (to date) of B3 histology, which focusses on estimating positive predictive values (PPV) for malignancy. We identified all B3 CNBs over a 10-year period in a single institution (N=372) from a series of 4035 consecutive needle biopsies. We describe the imaging findings, and report excision histology outcomes (N=279) and category-specific PPV for B3 lesions using two approaches including estimates based on subjects who had either excision or follow-up (N=328). B3 represented 9.2% of all CNB results. Excision histology was benign in 181 (64.9%) and malignant in 98 (35.1%) subjects (61 ductal carcinoma in situ, 37 invasive carcinoma). Positive predictive value for malignancy (based on excision histology) was 35.1% (95% CI: 29.5–40.7) and PPV (based on excision or review) was 29.9% (95% CI: 24.9–34.8). Lesion-specific PPV (estimates in parentheses for excision or follow-up) was atypical ductal hyperplasia 44.7% (40.6%); lobular intraepithelial neoplasia 60.9% (58.3%); papillary lesion 22.7% (15.9%); radial scar 16.7% (12.3%); phyllodes tumour 12.5% (12.5%); and B3 not specified 20.0%. Approximately one-third of CNB results classified as B3 are malignant on excision, and the likelihood of malignancy varies substantially between specific lesion groups. Whereas cases may be selectively managed without surgery, the majority warrant excision biopsy based on our estimates. Research is needed to improve differentiation between malignant and benign diseases in B3 lesions using diagnostic or predictive methods

    Course and Lethality of SARS-CoV2 Epidemic in Nursing Homes after Vaccination in Florence, Italy

    Get PDF
    Evidence on the effectiveness of SARS-CoV-2 vaccines in nursing home (NHs) residents is limited. We examined the impact of the BNT162b2 mRNA SARS-CoV-2 vaccine on the course of the epidemic in NHs in the Florence Health District, Italy, before and after vaccination. Moreover, we assessed survival and hospitalization by vaccination status in SARS-CoV-2-positive cases occurring during the post-vaccination period. We calculated the weekly infection rates during the pre-vaccination (1 October–26 December 2020) and post-vaccination period (27 December 2020–31 March 2021). Cox analysis was used to analyze survival by vaccination status. The study involved 3730 residents (mean age 84, 69% female). Weekly infection rates fluctuated during the pre-vaccination period (1.8%–6.5%) and dropped to zero during the post-vaccination period. Nine unvaccinated (UN), 56 partially vaccinated (PV) and 35 fully vaccinated (FV) residents tested SARS-CoV-2+ during the post-vaccination period. FV showed significantly lower hospitalization and mortality rates than PV and UV (hospitalization: FV 3%, PV 14%, UV 33%; mortality: FV 6%, PV 18%, UV 56%). The death risk was 84% and 96% lower in PV (HR 0.157, 95%CI 0.049–0.491) and FV (HR 0.037, 95%CI 0.006–0.223) versus UV. SARS-CoV-2 vaccination was followed by a marked decline in infection rates and was associated with lower morbidity and mortality among infected NH residents
    corecore