1,030 research outputs found

    Control of nonenzymatic browning in intermediate-moisture foods

    Get PDF
    Series of compounds called humectants were found to decrease rate of browning when added to intermediate-moisture foods. Twenty percent level of humectant can increase shelf life of foods by factor of 5 or 6

    High field magneto-transport in high mobility gated InSb/InAlSb quantum well heterostructures

    Get PDF
    We present high field magneto-transport data from a range of 30nm wide InSb/InAlSb quantum wells. The low temperature carrier mobility of the samples studied ranged from 18.4 to 39.5 m2V-1s-1 with carrier densities between 1.5x1015 and 3.28x1015 m-2. Room temperature mobilities are reported in excess of 6 m2V-1s-1. It is found that the Landau level broadening decreases with carrier density and beating patterns are observed in the magnetoresistance with non-zero node amplitudes in samples with the narrowest broadening despite the presence of a large g-factor. The beating is attributed to Rashba splitting phenomenon and Rashba coupling parameters are extracted from the difference in spin populations for a range of samples and gate biases. The influence of Landau level broadening and spin-dependent scattering rates on the observation of beating in the Shubnikov-de Haas oscillations is investigated by simulations of the magnetoconductance. Data with non-zero beat node amplitudes are accompanied by asymmetric peaks in the Fourier transform, which are successfully reproduced by introducing a spin-dependent broadening in the simulations. It is found that the low-energy (majority) spin up state suffers more scattering than the high-energy (minority) spin down state and that the absence of beating patterns in the majority of (lower density) samples can be attributed to the same effect when the magnitude of the level broadening is large

    Rapid point-of-care testing for COVID-19: quality of supportive information for lateral flow serology assays

    Get PDF
    Objective There is a lack of evidence addressing several important human factors questions pertaining to the quality of supportive information provided by commercial manufacturers that can affect the adoption and use of lateral flow serology assays in practice. We aimed to: (1) identify and assess the quality of information that commercial manufacturers provided for their point-of-care tests (POCTs) and (2) examine the implications of these findings on real-world settings. Design We used a content analysis methodology in two stages to systematically, code and analyse textual data from documents of commercial manufacturers. A deductive approach was applied using a coding guide based on the validated Point-of-Care Key Evidence Tool (POCKET) multidimensional checklist. An inductive approach was used to identify new patterns or themes generated from our textual analysis. Setting Publicly available supportive information documents by commercial manufacturers for lateral flow serology, were identified and gathered from online searches. Participants Supportive information documents retrieved from online searches over 3 months (March 2020 to June 2020). Results A total of 79 POCTs were identified that met the study inclusion criteria. Using the POCKET coding guide, we found that the quality of information varied significantly between the manufacturers and was often lacking in detail. Our inductive approach further examined these topics and found that several statements were vague and that significant variations in the level of details existed between manufacturers. Conclusions This study revealed significant concerns surrounding the supportive information reported by manufacturers for lateral flow serology assays. Information transparency was poor and human factor issues were not properly addressed to mitigate the risk of improper device use, although it should be noted that the results of our study are limited by the data that manufactures were prepared to disclose. Overall, commercial manufacturers should improve the quality and value of information presented in their supporting documentation

    Rodent control and island conservation

    Get PDF
    Most rodent species are highly adapted, selected, boom-or-bust strategists. Such pre-adaptation to invasiveness allows them quickly to take advantage of abundant new resources and is why rodents are among the most successful mammalian colonizers of islands. This chapter discusses the impacts of alien invasive rodents on natural ecosystems, with emphasis on oceanic islands, and review management techniques to mitigate their effects

    On the ubiquity of molecular anions in the dense interstellar medium

    Get PDF
    Results are presented from a survey for molecular anions in seven nearby Galactic star-forming cores and molecular clouds. The hydrocarbon anion C6H- is detected in all seven target sources, including four sources where no anions have been previously detected: L1172, L1389, L1495B and TMC-1C. The C6H-/C6H column density ratio is greater than about 1.0% in every source, with a mean value of 3.0% (and standard deviation 0.92%). Combined with previous detections, our results show that anions are ubiquitous in dense clouds wherever C6H is present. The C6H-/C6H ratio is found to show a positive correlation with molecular hydrogen number density, and with the apparent age of the cloud. We also report the first detection of C4H- in TMC-1 (at 4.8-sigma confidence), and derive an anion-to-neutral ratio C4H-/C4H = (1.2 +- 0.4) x 10^-5 (= 0.0012 +- 0.0004%). Such a low value compared with C6H- highlights the need for a revised radiative electron attachment rate for C4H. Chemical model calculations show that the observed C4H- could be produced as a result of reactions of oxygen atoms with C5H- and C6H-

    Tentative Evidence for Relativistic Electrons Generated by the Jet of the Young Sun-like Star DG Tau

    Full text link
    Synchrotron emission has recently been detected in the jet of a massive protostar, providing further evidence that certain jet formation characteristics for young stars are similar to those found for highly relativistic jets from AGN. We present data at 325 and 610 MHz taken with the GMRT of the young, low-mass star DG Tau, an analog of the Sun soon after its birth. This is the first investigation of a low-mass YSO at at such low frequencies. We detect emission with a synchrotron spectral index in the proximity of the DG Tau jet and interpret this emission as a prominent bow shock associated with this outflow. This result provides tentative evidence for the acceleration of particles to relativistic energies due to the shock impact of this otherwise very low-power jet against the ambient medium. We calculate the equipartition magnetic field strength (0.11 mG) and particle energy (4x10^40 erg), which are the minimum requirements to account for the synchrotron emission of the DG Tau bow shock. These results suggest the possibility of low energy cosmic rays being generated by young Sun-like stars.Comment: 19 pages, 2 figures, accepted for publication in ApJ Letter

    Shoulder posture and median nerve sliding

    Get PDF
    Background: Patients with upper limb pain often have a slumped sitting position and poorshoulder posture. Pain could be due to poor posture causing mechanical changes (stretch; localpressure) that in turn affect the function of major limb nerves (e.g. median nerve). This studyexamines (1) whether the individual components of slumped sitting (forward head position, trunkflexion and shoulder protraction) cause median nerve stretch and (2) whether shoulderprotraction restricts normal nerve movements.Methods: Longitudinal nerve movement was measured using frame-by-frame cross-correlationanalysis from high frequency ultrasound images during individual components of slumped sitting.The effects of protraction on nerve movement through the shoulder region were investigated byexamining nerve movement in the arm in response to contralateral neck side flexion.Results: Neither moving the head forward or trunk flexion caused significant movement of themedian nerve. In contrast, 4.3 mm of movement, adding 0.7% strain, occurred in the forearm duringshoulder protraction. A delay in movement at the start of protraction and straightening of thenerve trunk provided evidence of unloading with the shoulder flexed and elbow extended and thescapulothoracic joint in neutral. There was a 60% reduction in nerve movement in the arm duringcontralateral neck side flexion when the shoulder was protracted compared to scapulothoracicneutral.Conclusion: Slumped sitting is unlikely to increase nerve strain sufficient to cause changes tonerve function. However, shoulder protraction may place the median nerve at risk of injury, sincenerve movement is reduced through the shoulder region when the shoulder is protracted andother joints are moved. Both altered nerve dynamics in response to moving other joints and localchanges to blood supply may adversely affect nerve function and increase the risk of developingupper quadrant pain

    Pathway map development for medical device event reporting in operating theatres: a human factors approach to improving the existing system

    Get PDF
    OBJECTIVES: This study aimed to develop the actual pathway to reporting and information transfer in operating theatres in relation to medical technology malfunction/failure. This with the aim of understanding the differences with the pathway published by NHS Improvement and identification of points for improvement. DESIGN: This is a qualitative study involving stakeholder interviews with doctors, nurses, manufacturers, medical device safety officer and Medicines and Healthcare products Regulatory Agency. SETTING: Data were collected on reporting pathway used in operating theatres. Clinical staff who took part worked in different trusts throughout UK while manufacturers provided devices in UK and EU/USA. PARTICIPANTS: Semistructured interviews were completed with 15 clinicians and 13 manufacturers. Surveys were completed by 38 clinicians and 5 manufacturers. Recognised methods of pathway development were used. The Lean Six Sigma principles adapted to healthcare were used to develop suggestions for improvement. MAIN OUTCOME MEASURES: To identify the differences between the set pathway to reporting and information transfer to what is occurring on a day-to-day basis as reported by staff. Identify points in the pathway where improvements could be applied. RESULTS: The developed pathway demonstrated great complexity of the current reporting system for medical devices. It identified numerous areas that give rise to problems and multiple biases in decision making. This highlighted the core issues leading to under-reporting and lack of knowledge on device performance and patient risk. Suggestions for improvement were deduced based on end user requirements and identified problems. CONCLUSIONS: This study has provided a detailed understanding of the key problem areas that exist within the current reporting system for medical devices and technology. The developed pathway sets to address the key problems to improve reporting outcomes. The identification of pathway differences between 'work as done' and 'work as imagined' can lead to development of quality improvements that could be systematically applied

    A Surface-Gated InSb Quantum Well Single Electron Transistor

    Full text link
    Single electron charging effects in a surface-gated InSb/AlInSb QW structure are reported. This material, due to its large g-factor and light effective mass, offers considerable advantages over more commonly used materials, such as GaAs, for quantum information processing devices. However, differences in material and device technology result in significant processing challenges. Simple Coulomb blockade and quantised confinement models are considered to explain the observation of conductance oscillations in these structures. The charging energy is found to be comparable with the energy spectrum for single particle states

    JHK Observations of Faint Standard Stars in the Mauna Kea Near-Infrared Photometric System

    Get PDF
    JHK photometry in the Mauna Kea Observatory (MKO) near-IR system is presented for 115 stars. Of these, 79 are UKIRT standards and 42 are LCO standards. The average brightness is 11.5 mag, with a range of 10 to 15. The average number of nights each star was observed is 4, and the average of the internal error of the final results is 0.011 mag. These JHK data agree with those reported by other groups to 0.02 mag. The measurements are used to derive transformations between the MKO JHK photometric system and the UKIRT, LCO and 2MASS systems. The 2MASS-MKO data scatter by 0.05 mag for redder stars: 2MASS-J includes H2O features in dwarfs and MKO-K includes CO features in giants. Transformations derived for stars whose spectra contain only weak features cannot give accurate transformations for objects with strong absorption features within a filter bandpasses. We find evidence of systematic effects at the 0.02 mag level in the photometry of stars with J<11 and H,K<10.5. This is due to an underestimate of the linearity correction for stars observed with the shortest exposure times; very accurate photometry of stars approaching the saturation limits of infrared detectors which are operated in double-read mode is difficult to obtain. Four stars in the sample, GSPC S705-D, FS 116 (B216-b7), FS 144 (Ser-EC84) and FS 32 (Feige 108), may be variable. 84 stars in the sample have 11< J< 15 and 10.5<H,K<15, are not suspected to be variable, and have magnitudes with an estimated error <0.027 mag; 79 of these have an error of <0.020 mag. These represent the first published high-accuracy JHK stellar photometry in the MKO photometric system; we recommend these objects be employed as primary standards for that system [abridged].Comment: Accepted for publication in MNRAS, 14 pages, 5 Figure
    • …
    corecore