362 research outputs found

    Judicial Review of Labor Arbitration Awards After the Trilogy

    Get PDF

    Judicial Review of Labor Arbitration Awards After the Trilogy

    Get PDF

    Mass Spectrometry on Future Mars Landers

    Get PDF
    Mass spectrometry investigations on the 2011 Mars Science Laboratory (MSL) and the 2018 ExoMars missions will address core science objectives related to the potential habitability of their landing site environments and more generally the near-surface organic inventory of Mars. The analysis of complex solid samples by mass spectrometry is a well-known approach that can provide a broad and sensitive survey of organic and inorganic compounds as well as supportive data for mineralogical analysis. The science value of such compositional information is maximized when one appreciates the particular opportunities and limitations of in situ analysis with resource-constrained instrumentation in the context of a complete science payload and applied to materials found in a particular environment. The Sample Analysis at Mars (SAM) investigation on MSL and the Mars Organic Molecule Analyzer (MOMA) investigation on ExoMars will thus benefit from and inform broad-based analog field site work linked to the Mars environments where such analysis will occur

    Magnetization and dynamics of reentrant ferrimagnetic spin-glass [MnTPP]::+[TCNE].-.2PhMe

    Get PDF
    Journal ArticleWe present direct current (dc) magnetization M(T,H) and alternating current (ac) susceptibility Xac(T,H,f) data for the quasi-one-dimensional molecule-based ferrimagnet [MnTPP]::+[TCNE].-.•2PhMe (TPP=meso-tetraphenylporphyrinato, TCNE=tetracyanoethylene). Static scaling of the real part X' of the ac susceptibility and data collapse of M(T,H) over a limited reduced temperature range above Tc=13 K lead to the critical exponents y=1.6, B=0.5, and 8=4.2. Below Tc , Xac depends sensitively on frequency and exhibits a striking double-peak structure similar to that found in reentrant spin glasses. Possible models for the frequency dependence of the peaks observed in Xac are discussed

    The Icebreaker Mission to Search for Life on Mars

    Get PDF
    The search for evidence of life on Mars is the ultimate motivation for its scientific exploration. The results from the Phoenix mission indicate that the high N. latitude ice-rich regolith at low elevations is likely to be a recently habitable place on Mars [Stoker et al., 2010]. The near-surface ice likely provided adequate water activity during periods of high obliquity, 3 to 10 Myr ago. Carbon dioxide and nitrogen are present in the atmosphere, and nitrates may be present in the soil. Together with iron in basaltic rocks and perchlorate in the soil they provide carbon and energy sources, and oxidative power to drive metabolism. Furthermore, the presence of organics is possible, as thermally reactive perchlorate would have prevented their detection by Viking and Phoenix. The Mars Icebreaker Life mission [McKay et al., 2013] focuses on the following science goals: (1) Search for biomolecular evidence of life; (2) Search for organic matter from either exogeneous or endogeneous sources using methods that are not effected by the presence of perchlorate; (3) Characterize oxidative species that produced reactivity of soils seen by Viking; and 4) Assess the habitability of the ice bearing soils. The Icebreaker Life payload (Figure 1) includes a 1-m rotary percussive drill that brings cuttings samples to the surface where they are delivered to three instruments (Fig. 1), the Signs of Life Detector (SOLID) [Parro et al., 2011] for biomolecular analysis, Laser Desorption Mass Spectrometer (LDMS) [??? 2015]) for broad spectrum organic analysis, and Wet Chemistry Laboratory (WCL) [Hecht et al., 2009] for detecting soluble species of nutrients and reactive oxidants. The Icebreaker payload fits on the Phoenix spacecraft and can land at the well-characterized Phoe-nix landing site in 2020 in a Discovery-class mission

    Laser Ablation Mass Spectrometer (LAMS) as a Standoff Analyzer in Space Missions for Airless Bodies

    Get PDF
    A laser ablation mass spectrometer (LAMS) based on a time-of-flight (TOF) analyzer with adjustable drift length is proposed as a standoff elemental composition sensor for space missions to airless bodies. It is found that the use of a retarding potential analyzer in combination with a two-stage reflectron enables LAMS to be operated at variable drift length. For field-free drift lengths between 33 cm to 100 cm, at least unit mass resolution can be maintained solely by adjustment of internal voltages, and without resorting to drastic reductions in sensitivity. Therefore, LAMS should be able to be mounted on a robotic arm and analyze samples at standoff distances of up to several tens of cm, permitting high operational flexibility and wide area coverage of heterogeneous regolith on airless bodies

    Investigating the Origin and Evolution of Venus with In Situ Mass Spectrometry

    Get PDF
    The exploration of Venus continues to be a top priority of planetary science. The Planetary Decadal Survey goals for inner-planet exploration seek to discern the origin and diversity of terrestrial planets, understand how the evolution of terrestrial planets relates to the evolution of life, and explore the processes that control climate on Earth-like planets [1]. These goals can only be realized through continued and extensive exploration of Venus, the most mysterious of the terrestrial planets, remarkably different from the Earth despite the gross similarities between these twin planets. It is unknown if this apparent divergence was intrinsic, programmed during accretion from distinct nebular reservoirs, or a consequence of either measured or catastrophic processes during planetary evolution. Even if the atmosphere of Venus is a more recent development, its relationship to the resurfacing of the planets enigmatic surface is not well understood. Resolving such uncertainties directly addresses the hypothesis of a more clement, possibly water-rich era in Venus past as well as whether Earth could become more Venus-like in the future

    A Miniature Laser Desorption/Ionization Time-of-Flight Mass Spectrometer for in Situ Analysis of Mars Surface Composition and Identification of Hazard in Advance of Future Manned Exploration

    Get PDF
    Future landed missions to Mars will be guided by two strategic directions: (1) sample return to Earth, for comprehensive compositional analyses, as recommended by the 2011 NRC Planetary Decadal Survey; and (2) preparation for human exploration in the 2030s and beyond, as laid out by US space policy. The resultant mission architecture will likely require high-fidelity in situ chemical/organic sample analyses within an extremely constrained resource envelope. Both science goals (e.g., MEPAG Goal 1, return sample selection, etc.) as well as identification of any potential toxic and biological hazards to humans, must be addressed. Over the past several years of instrument development, we have found that the adaptable, compact, and highly capable technique of laser desorption/ionization time-of-flight mass spectrometry (LD-TOF-MS) has significant potential to contribute substantially to these dual objectives. This concept thus addresses Challenge Area 1: instrumentation and Investigation Approaches

    Development of a Low Power Gas Chromatograph-Mass Spectrometer for In-Situ Detection of Organics in Martian Soil

    Get PDF
    The Mars Organic Molecule Analyzer (MOMA) is a joint venture by NASA and the European Space Agency (ESA) to develop a sensitive, light-weight, low-power mass spectrometer for chemical analysis on Mars. MOMA is a key analytical instrument aboard the 2018 ExoMars rover mission seeking signs of past or present life. The current prototype was built to demonstrate operation of gas chromatography (OC) and laser desorption (LD) mass spectrometry under martian ambient conditions (5-7 Torr of CO2-rich atmosphere). Recent reports have discussed the MO MA concept, design and performance. Here, we update the current prototype performance, focusing specifically on the GCMS mode

    Observation of an unusual field dependent slow magnetic relaxation and two distinct transitions in a family of new complexes

    Full text link
    An unusual field dependent slow magnetic relaxation and two distinct transitions were observed in a family of new rare earth-transition metal complexes, [Ln (bipy) (H2_{2}O)4_{4} M(CN)6_{6}] â‹…\cdot 1.5 (bipy) â‹… \cdot 4H2_{2}O (bipy = 2,2'-bipyridine; Ln = Gd3+^{3+},Y3+^{3+}; M = Fe3+ ^{3+}, Co3+^{3+}). The novel magnetic relaxation, which is quite different from those in normal spin glasses and superparamagnets but very resembles qualitatively those in single-molecule magnet Mn12_{12}-Ac even if they possess different structures, might be attributed to the presence of frustration that is incrementally unveiled by the external magnetic field. The two distinct transitions in [GdFe] were presumed from DC and AC susceptibility as well as heat capacity measurements.Comment: Revtex, 6 figure
    • …
    corecore