17 research outputs found
Multicenter Assessment of Radiation Exposure during Pediatric Cardiac Catheterizations Using a Novel Imaging System
Total Anomalous Pulmonary Venous Connection: Preoperative Anatomy, Physiology, Imaging, and Interventional Management of Postoperative Pulmonary Venous Obstruction
Percutaneous Impella RP use for refractory right heart failure in adolescents and young adults-A multicenter U.S. experience.
OBJECTIVE: To assess the outcomes of the use of the percutaneous Impella RP device (Abiomed, Danvers, MA) in adolescents and young adults.
BACKGROUND: Results of the Impella RP device have been reported in adults, but a multicenter experience in adolescents and young adults has yet to be reported.
METHODS: Patients ≤21 years of age who underwent implantation of an Impella RP device for refractory right heart failure from June, 2016 to April, 2018 at nine U.S. Centers were included.
RESULTS: A total of 12 adolescents, median age of 18 (14-21) years and median weight 74.4 (49-112.4) kg underwent Impella RP implantation (INTERMACS Profile 1 in nine and Profile 2 in three patients. The central venous pressure decreased from 20 (16-35) to 12 (7-17) mmHg, (p = .001). One patient was concomitantly supported with an intra-aortic balloon pump (IABP) and the rest with a percutaneous/surgically placed left ventricular assist device. There was one adverse event related to the Impella RP device (thrombosis requiring explant). The support duration was 6.5 days (4.8 hr-18.4 days) and survival to hospital discharge was 83%. At a median follow-up of 11 months (5 days-2.5 years), 8 of 12 (67%) patients are alive.
CONCLUSIONS: In this multicenter experience, the Impella RP device was found to be efficacious and safe when used in adolescents and young adults. Further studies are warranted to identify suitable young/pediatric candidates for Impella RP therapy for right heart failure
Percutaneous Impella RP use for refractory right heart failure in adolescents and young adults-A multicenter US experience
OBJECTIVE: To assess the outcomes of the use of the percutaneous Impella RP device (Abiomed, Danvers, MA) in adolescents and young adults.
BACKGROUND: Results of the Impella RP device have been reported in adults, but a multicenter experience in adolescents and young adults has yet to be reported.
METHODS: Patients ≤21 years of age who underwent implantation of an Impella RP device for refractory right heart failure from June, 2016 to April, 2018 at nine U.S. Centers were included.
RESULTS: A total of 12 adolescents, median age of 18 (14-21) years and median weight 74.4 (49-112.4) kg underwent Impella RP implantation (INTERMACS Profile 1 in nine and Profile 2 in three patients. The central venous pressure decreased from 20 (16-35) to 12 (7-17) mmHg, (p = .001). One patient was concomitantly supported with an intra-aortic balloon pump (IABP) and the rest with a percutaneous/surgically placed left ventricular assist device. There was one adverse event related to the Impella RP device (thrombosis requiring explant). The support duration was 6.5 days (4.8 hr-18.4 days) and survival to hospital discharge was 83%. At a median follow-up of 11 months (5 days-2.5 years), 8 of 12 (67%) patients are alive.
CONCLUSIONS: In this multicenter experience, the Impella RP device was found to be efficacious and safe when used in adolescents and young adults. Further studies are warranted to identify suitable young/pediatric candidates for Impella RP therapy for right heart failure
Percutaneous Impella RP use for refractory right heart failure in adolescents and young adults—A multicenter U.S. experience
Intentional Fracture of Bioprosthetic Valve Frames in Patients Undergoing Valve-in-Valve Transcatheter Pulmonary Valve Replacement.
BACKGROUND: Percutaneous transcatheter pulmonary valve replacement (TPVR) has good clinical and hemodynamic outcomes in treating dysfunctional bioprosthetic valves (BPV) in the pulmonary position. Valve-in-valve therapy can further decrease the inner diameter (ID), potentially resulting in patient-prosthesis mismatch in patients with smaller BPVs.
METHODS AND RESULTS: To evaluate feasibility and outcomes of intentional BPV fracture to enlarge the pulmonary valve orifice with TPVR, 37 patients from 13 centers who underwent TPVR with intended BPV fracture were evaluated. A control cohort (n=70) who underwent valve-in-valve TPVR without attempted fracture was evaluated. BPV was successfully fractured in 28 patients and stretched in 5 while fracture was unsuccessful in 4. A Melody valve was implanted in 25 patients with fractured/stretched frame and a Sapien (XT 3) valve in 8. Among patients whose BPV was fractured/stretched, the final ID was a median of 2 mm larger (0-6.5 mm) than the valve\u27s true ID. The narrowest diameter after TPVR in controls was a median of 2 mm smaller ( P
CONCLUSIONS: Preliminary experience shows intentional fracture of BPV frame can be useful for achieving larger ID and better hemodynamics after valve-in-valve TPVR
Intentional Fracture of Bioprosthetic Valve Frames in Patients Undergoing Valve-in-Valve Transcatheter Pulmonary Valve Replacement
BACKGROUND: Percutaneous transcatheter pulmonary valve replacement (TPVR) has good clinical and hemodynamic outcomes in treating dysfunctional bioprosthetic valves (BPV) in the pulmonary position. Valve-in-valve therapy can further decrease the inner diameter (ID), potentially resulting in patient-prosthesis mismatch in patients with smaller BPVs. METHODS AND RESULTS: To evaluate feasibility and outcomes of intentional BPV fracture to enlarge the pulmonary valve orifice with TPVR, 37 patients from 13 centers who underwent TPVR with intended BPV fracture were evaluated. A control cohort (n=70) who underwent valve-in-valve TPVR without attempted fracture was evaluated. BPV was successfully fractured in 28 patients and stretched in 5 while fracture was unsuccessful in 4. A Melody valve was implanted in 25 patients with fractured/stretched frame and a Sapien (XT 3) valve in 8. Among patients whose BPV was fractured/stretched, the final ID was a median of 2 mm larger (0-6.5 mm) than the valve's true ID. The narrowest diameter after TPVR in controls was a median of 2 mm smaller ( P<0.001) than true ID. Right ventricular outflow tract gradient decreased from median 40 to 8 mm Hg in the fracture group. Cases with fracture/stretching were matched 1:1 (weight, true ID) to controls. Post-TPVR peak gradient was lower but not significant (8.3±5.2 versus 11.8±9.2 mm Hg; P=0.070). There were no fracture-related adverse events. CONCLUSIONS: Preliminary experience shows intentional fracture of BPV frame can be useful for achieving larger ID and better hemodynamics after valve-in-valve TPVR.status: publishe
Multicenter Experience Evaluating Transcatheter Pulmonary Valve Replacement in Bovine Jugular Vein (Contegra) Right Ventricle to Pulmonary Artery Conduits
Follow-up of transcatheter pulmonary valve replacement (TPVR) with the Melody valve has demonstrated good short-term and long-term outcomes, but there are no published studies focused on valve performance in the Contegra bovine jugular vein conduit.status: publishe