17 research outputs found

    Percutaneous Impella RP use for refractory right heart failure in adolescents and young adults-A multicenter U.S. experience.

    No full text
    OBJECTIVE: To assess the outcomes of the use of the percutaneous Impella RP device (Abiomed, Danvers, MA) in adolescents and young adults. BACKGROUND: Results of the Impella RP device have been reported in adults, but a multicenter experience in adolescents and young adults has yet to be reported. METHODS: Patients ≤21 years of age who underwent implantation of an Impella RP device for refractory right heart failure from June, 2016 to April, 2018 at nine U.S. Centers were included. RESULTS: A total of 12 adolescents, median age of 18 (14-21) years and median weight 74.4 (49-112.4) kg underwent Impella RP implantation (INTERMACS Profile 1 in nine and Profile 2 in three patients. The central venous pressure decreased from 20 (16-35) to 12 (7-17) mmHg, (p = .001). One patient was concomitantly supported with an intra-aortic balloon pump (IABP) and the rest with a percutaneous/surgically placed left ventricular assist device. There was one adverse event related to the Impella RP device (thrombosis requiring explant). The support duration was 6.5 days (4.8 hr-18.4 days) and survival to hospital discharge was 83%. At a median follow-up of 11 months (5 days-2.5 years), 8 of 12 (67%) patients are alive. CONCLUSIONS: In this multicenter experience, the Impella RP device was found to be efficacious and safe when used in adolescents and young adults. Further studies are warranted to identify suitable young/pediatric candidates for Impella RP therapy for right heart failure

    Percutaneous Impella RP use for refractory right heart failure in adolescents and young adults-A multicenter US experience

    No full text
    OBJECTIVE: To assess the outcomes of the use of the percutaneous Impella RP device (Abiomed, Danvers, MA) in adolescents and young adults. BACKGROUND: Results of the Impella RP device have been reported in adults, but a multicenter experience in adolescents and young adults has yet to be reported. METHODS: Patients ≤21 years of age who underwent implantation of an Impella RP device for refractory right heart failure from June, 2016 to April, 2018 at nine U.S. Centers were included. RESULTS: A total of 12 adolescents, median age of 18 (14-21) years and median weight 74.4 (49-112.4) kg underwent Impella RP implantation (INTERMACS Profile 1 in nine and Profile 2 in three patients. The central venous pressure decreased from 20 (16-35) to 12 (7-17) mmHg, (p = .001). One patient was concomitantly supported with an intra-aortic balloon pump (IABP) and the rest with a percutaneous/surgically placed left ventricular assist device. There was one adverse event related to the Impella RP device (thrombosis requiring explant). The support duration was 6.5 days (4.8 hr-18.4 days) and survival to hospital discharge was 83%. At a median follow-up of 11 months (5 days-2.5 years), 8 of 12 (67%) patients are alive. CONCLUSIONS: In this multicenter experience, the Impella RP device was found to be efficacious and safe when used in adolescents and young adults. Further studies are warranted to identify suitable young/pediatric candidates for Impella RP therapy for right heart failure

    Intentional Fracture of Bioprosthetic Valve Frames in Patients Undergoing Valve-in-Valve Transcatheter Pulmonary Valve Replacement.

    No full text
    BACKGROUND: Percutaneous transcatheter pulmonary valve replacement (TPVR) has good clinical and hemodynamic outcomes in treating dysfunctional bioprosthetic valves (BPV) in the pulmonary position. Valve-in-valve therapy can further decrease the inner diameter (ID), potentially resulting in patient-prosthesis mismatch in patients with smaller BPVs. METHODS AND RESULTS: To evaluate feasibility and outcomes of intentional BPV fracture to enlarge the pulmonary valve orifice with TPVR, 37 patients from 13 centers who underwent TPVR with intended BPV fracture were evaluated. A control cohort (n=70) who underwent valve-in-valve TPVR without attempted fracture was evaluated. BPV was successfully fractured in 28 patients and stretched in 5 while fracture was unsuccessful in 4. A Melody valve was implanted in 25 patients with fractured/stretched frame and a Sapien (XT 3) valve in 8. Among patients whose BPV was fractured/stretched, the final ID was a median of 2 mm larger (0-6.5 mm) than the valve\u27s true ID. The narrowest diameter after TPVR in controls was a median of 2 mm smaller ( P CONCLUSIONS: Preliminary experience shows intentional fracture of BPV frame can be useful for achieving larger ID and better hemodynamics after valve-in-valve TPVR

    Intentional Fracture of Bioprosthetic Valve Frames in Patients Undergoing Valve-in-Valve Transcatheter Pulmonary Valve Replacement

    No full text
    BACKGROUND: Percutaneous transcatheter pulmonary valve replacement (TPVR) has good clinical and hemodynamic outcomes in treating dysfunctional bioprosthetic valves (BPV) in the pulmonary position. Valve-in-valve therapy can further decrease the inner diameter (ID), potentially resulting in patient-prosthesis mismatch in patients with smaller BPVs. METHODS AND RESULTS: To evaluate feasibility and outcomes of intentional BPV fracture to enlarge the pulmonary valve orifice with TPVR, 37 patients from 13 centers who underwent TPVR with intended BPV fracture were evaluated. A control cohort (n=70) who underwent valve-in-valve TPVR without attempted fracture was evaluated. BPV was successfully fractured in 28 patients and stretched in 5 while fracture was unsuccessful in 4. A Melody valve was implanted in 25 patients with fractured/stretched frame and a Sapien (XT 3) valve in 8. Among patients whose BPV was fractured/stretched, the final ID was a median of 2 mm larger (0-6.5 mm) than the valve's true ID. The narrowest diameter after TPVR in controls was a median of 2 mm smaller ( P<0.001) than true ID. Right ventricular outflow tract gradient decreased from median 40 to 8 mm Hg in the fracture group. Cases with fracture/stretching were matched 1:1 (weight, true ID) to controls. Post-TPVR peak gradient was lower but not significant (8.3±5.2 versus 11.8±9.2 mm Hg; P=0.070). There were no fracture-related adverse events. CONCLUSIONS: Preliminary experience shows intentional fracture of BPV frame can be useful for achieving larger ID and better hemodynamics after valve-in-valve TPVR.status: publishe

    Multicenter Experience Evaluating Transcatheter Pulmonary Valve Replacement in Bovine Jugular Vein (Contegra) Right Ventricle to Pulmonary Artery Conduits

    No full text
    Follow-up of transcatheter pulmonary valve replacement (TPVR) with the Melody valve has demonstrated good short-term and long-term outcomes, but there are no published studies focused on valve performance in the Contegra bovine jugular vein conduit.status: publishe
    corecore