270 research outputs found
HERO: A Balloon-Borne Focusing Hard X-Ray Telescope
This viewgraph presentation describes the HERO balloon-borne payload configuration, instrument specifications, flight operations, sensitivity analyses, and future flight plans
Methods of optimizing X-ray optical prescriptions for wide-field applications
We are working on the development of a method for optimizing wide-field X-ray
telescope mirror prescriptions, including polynomial coefficients, mirror shell
relative displacements, and (assuming 4 focal plane detectors) detector
placement along the optical axis and detector tilt. With our methods, we hope
to reduce number of Monte-Carlo ray traces required to search the
multi-dimensional design parameter space, and to lessen the complexity of
finding the optimum design parameters in that space. Regarding higher order
polynomial terms as small perturbations of an underlying Wolter I optic design,
we begin by using the results of Monte-Carlo ray traces to devise trial
analytic functions, for an individual Wolter I mirror shell, that can be used
to represent the spatial resolution on an arbitrary focal surface. We then
introduce a notation and tools for Monte-Carlo ray tracing of a polynomial
mirror shell prescription which permits the polynomial coefficients to remain
symbolic. In principle, given a set of parameters defining the underlying
Wolter I optics, a single set of Monte-Carlo ray traces are then sufficient to
determine the polymonial coefficients through the solution of a large set of
linear equations in the symbolic coefficients. We describe the present status
of this development effort.Comment: 14 pages, to be presented at SPIE conference 7732 (paper 93
Nickel cobalt phosphorous low stress electroplating
An electrolytic plating process is provided for electrodepositing a nickel or nickel cobalt alloy which contains at least about 2% to 25% by atomic volume of phosphorous. The process solutions contains nickel and optionally cobalt sulfate, hypophosphorous acid or a salt thereof, boric acid or a salt thereof, a monodentate organic acid or a salt thereof, and a multidentate organic acid or a salt thereof. The pH of the plating bath is from about 3.0 to about 4.5. An electroplating process is also provided which includes electroplating from the bath a nickel or nickel cobalt phosphorous alloy. This process can achieve a deposit with high microyield of at least about 84 kg/mm.sup.2 (120 ksi) and a density lower than pure nickel of about 8.0 gm/cc. This process can be used to plate a deposit of essentially zero stress at plating temperatures from ambient to 70.degree. C
Differential Deposition Technique for Figure Corrections in Grazing Incidence X-ray Optics
A differential deposition technique is being developed to correct the low- and mid-spatial-frequency deviations in the axial figure profile of Wolter type grazing incidence X-ray optics. These deviations arise due to various factors in the fabrication process and they degrade the performance of the optics by limiting the achievable angular resolution. In the differential deposition technique, material of varying thickness is selectively deposited along the length of the optic to minimize these deviations, thereby improving the overall figure. High resolution focusing optics being developed at MSFC for small animal radionuclide imaging are being coated to test the differential deposition technique. The required spatial resolution for these optics is 100 m. This base resolution is achievable with the regular electroform-nickel-replication fabrication technique used at MSFC. However, by improving the figure quality of the optics through differential deposition, we aim at significantly improving the resolution beyond this value
Optics Requirements for X-Ray Astronomy and Developments at the Marshall Space Flight Center
No abstract availabl
An Investigation of Differential Deposition for Figure Corrections in Full-Shell Grazing-Incidents X-Ray Optics
We are investigating differential deposition as a way of correcting small figure errors inside full-shell grazing-incidence x-ray optics. The optics in our study are fabricated using the electroformed-nickel-replication technique, and the figure errors arise from fabrication errors in the mandrel, from which the shells are replicated, as well as errors induced during the electroforming process. Combined, these give sub-micron-scale figure deviations which limit the angular resolution of the optics to approx. 10 arcsec. Sub-micron figure errors can be corrected by selectively depositing (physical vapor deposition) material inside the shell. The requirements for this filler material are that it must not degrade the ultra-smooth surface finish necessary for efficient x-ray reflection (approx. 5 A rms), and must not be highly stressed. In addition, a technique must be found to produce well controlled and defined beams within highly constrained geometries, as some of our mirror shells are less than 3 cm in diameter
Improving X-Ray Optics via Differential Deposition
Differential deposition, a post-fabrication figure correction technique, has the potential to significantly improve the imaging quality of grazing-incidence X-ray optics. DC magnetron sputtering is used to selectively coat the mirror in order to minimize the figure deviations. Custom vacuum chambers have been developed at NASA MSFC that will enable the implementation of the deposition on X-ray optics. A factor of two improvement has been achieved in the angular resolution of the full-shell X-ray optics with first stage correction of differential deposition. Current efforts are focused on achieving higher improvements through efficient implementation of differential deposition
- …