9 research outputs found

    Dose optimization of breast balloon brachytherapy using a stepping 192 Ir HDR source

    No full text
    To develop dose optimization schemes of breast balloon brachytherapy using a stepping of 192Ir HDR source. There is a considerable underdosage (11%–13%) of PTV due to anisotropy of a stationary source in breast balloon brachytherapy. We improved the PTV coverage by varying multiple dwell positions and weights. We assumed that the diameter of spherical balloons varied from 4.0 cm to 5.0 cm, that the PTV was a 1-cm thick spherical shell over the balloon (reduced by the small portion occupied by the catheter path), and that the number of dwell positions varied from 2 to 13 with 0.25-cm steps, oriented symmetrically with respect to the balloon center. By assuming that the perfect PTV coverage can be achieved by spherical dose distributions from an isotropic source, we developed an optimization program to minimize two objective functions defined as: (1) the number of PTV-voxels having more than 10% difference between optimized doses and spherical doses, and (2) the difference between optimized doses and spherical doses per PTV-voxel. The optimal PTV coverage occurred when applying 8–11 dwell positions wit

    The virtual cone: A novel technique to generate spherical dose distributions using a multileaf collimator and standardized control-point sequence for small target radiation surgery

    No full text
    Purpose: The study aimed to develop and demonstrate a standardized linear accelerator multileaf collimator-based method of delivering small, spherical dose distributions suitable for radiosurgical treatment of small targets such as the trigeminal nerve. Methods and materials: The virtual cone is composed of a multileaf collimator–defined field with the central 2 leaves set to a small gap. For 5 table positions, clockwise and counter-clockwise arcs were used with collimator angles of 45 and 135 degrees, respectively. The dose per degree was proportional to the sine of the gantry angle. The dose distribution was calculated by the treatment planning system and measured using radiochromic film in a skull phantom for leaf gaps of 1.6, 2.1, and 2.6 mm. Cones with a diameter of 4 mm and 5 mm were measured for comparison. Output factor constancy was investigated using a parallel-plate chamber. Results: The mean ratio of the measured-to-calculated dose was 0.99, 1.03, and 1.05 for 1.6, 2.1, and 2.6 mm leaf gaps, respectively. The diameter of the measured (calculated) 50% isodose line was 4.9 (4.6) mm, 5.2 (5.1) mm, and 5.5 (5.5) mm for the 1.6, 2.1, and 2.6 mm leaf gap, respectively. The measured diameter of the 50% isodose line was 4.5 and 5.7 mm for the 4 mm and 5 mm cones, respectively. The standard deviation of the parallel-plate chamber signal relative to a 10 cm × 10 cm field was less than 0.4%. The relative signal changed 32% per millimeter change in leaf gap, indicating that the parallel-plate chamber is sensitive to changes in gap width. Conclusions: The virtual cone is an efficient technique for treatment of small spherical targets. Patient-specific quality assurance measurements will not be necessary in routine clinical use. Integration directly into the treatment planning system will make planning using this technique extremely efficient

    Treatment of advanced hepatocellular carcinoma with very low levels of amplitude-modulated electromagnetic fields

    No full text
    Background: Therapeutic options for patients with advanced hepatocellular carcinoma (HCC) are limited. There is emerging evidence that the growth of cancer cells may be altered by very low levels of electromagnetic fields modulated at specific frequencies. Methods: A single-group, open-label, phase I/II study was performed to assess the safety and effectiveness of the intrabuccal administration of very low levels of electromagnetic fields amplitude modulated at HCC-specific frequencies in 41 patients with advanced HCC and limited therapeutic options. Three-daily 60-min outpatient treatments were administered until disease progression or death. Imaging studies were performed every 8 weeks. The primary efficacy end point was progression-free survival ⩾6 months. Secondary efficacy end points were progression-free survival and overall survival. Results: Treatment was well tolerated and there were no NCI grade 2, 3 or 4 toxicities. In all, 14 patients (34.1%) had stable disease for more than 6 months. Median progression-free survival was 4.4 months (95% CI 2.1–5.3) and median overall survival was 6.7 months (95% CI 3.0–10.2). There were three partial and one near complete responses. Conclusion: Treatment with intrabuccally administered amplitude-modulated electromagnetic fields is safe, well tolerated, and shows evidence of antitumour effects in patients with advanced HCC.ISSN:0007-0920ISSN:1532-182