16 research outputs found

    A time-resolved proteomic and prognostic map of COVID-19

    Get PDF
    COVID-19 is highly variable in its clinical presentation, ranging from asymptomatic infection to severe organ damage and death. We characterized the time-dependent progression of the disease in 139 COVID-19 inpatients by measuring 86 accredited diagnostic parameters, such as blood cell counts and enzyme activities, as well as untargeted plasma proteomes at 687 sampling points. We report an initial spike in a systemic inflammatory response, which is gradually alleviated and followed by a protein signature indicative of tissue repair, metabolic reconstitution, and immunomodulation. We identify prognostic marker signatures for devising risk-adapted treatment strategies and use machine learning to classify therapeutic needs. We show that the machine learning models based on the proteome are transferable to an independent cohort. Our study presents a map linking routinely used clinical diagnostic parameters to plasma proteomes and their dynamics in an infectious disease

    Clinical and virological characteristics of hospitalised COVID-19 patients in a German tertiary care centre during the first wave of the SARS-CoV-2 pandemic: a prospective observational study

    Get PDF
    Purpose: Adequate patient allocation is pivotal for optimal resource management in strained healthcare systems, and requires detailed knowledge of clinical and virological disease trajectories. The purpose of this work was to identify risk factors associated with need for invasive mechanical ventilation (IMV), to analyse viral kinetics in patients with and without IMV and to provide a comprehensive description of clinical course. Methods: A cohort of 168 hospitalised adult COVID-19 patients enrolled in a prospective observational study at a large European tertiary care centre was analysed. Results: Forty-four per cent (71/161) of patients required invasive mechanical ventilation (IMV). Shorter duration of symptoms before admission (aOR 1.22 per day less, 95% CI 1.10-1.37, p < 0.01) and history of hypertension (aOR 5.55, 95% CI 2.00-16.82, p < 0.01) were associated with need for IMV. Patients on IMV had higher maximal concentrations, slower decline rates, and longer shedding of SARS-CoV-2 than non-IMV patients (33 days, IQR 26-46.75, vs 18 days, IQR 16-46.75, respectively, p < 0.01). Median duration of hospitalisation was 9 days (IQR 6-15.5) for non-IMV and 49.5 days (IQR 36.8-82.5) for IMV patients. Conclusions: Our results indicate a short duration of symptoms before admission as a risk factor for severe disease that merits further investigation and different viral load kinetics in severely affected patients. Median duration of hospitalisation of IMV patients was longer than described for acute respiratory distress syndrome unrelated to COVID-19

    Impact of the Aortic Geometry on TAVI Prosthesis Positioning Using Self-Expanding Valves

    No full text
    Background: The impact of transcatheter heart valve (THV) position on the occurrence of paravalvular leakage and permanent pacemaker implantation caused by new-onset conduction disturbances is well described. The purpose of this study was to investigate the influence of the geometry of the thoracic aorta on the implantation depth after TAVI (transcatheter heart valve implantation) using self-expanding valve (SEV) types. Methods: We evaluated three-dimensional geometry of the thoracic aorta based on computed tomography angiography (CTA) in 104 subsequently patients receiving TAVI with SEV devices (Evolut R). Prosthesis position was determined using the fusion imaging method of pre- and post-procedural CTA. An implantation depth of &ge;4 mm was defined as the cut-off value for low prosthesis position. Results: The mean implantation depth of the THV in the whole cohort was 4.3 &plusmn; 3.0 mm below annulus plane. THV position was low in 66 (63.5%) patients and high in 38 (36.5%) patients. After multivariate adjustment none of the aortic geometry characteristics showed an independent influence on the prosthesis position&mdash;neither the Sinus of Valsalva area (p = 0.335) nor the proximal aortic arch diameter (p = 0.754) or the distance from annulus to descending aorta (p = 0.309). Conclusion: The geometry of the thoracic aorta showed no influence on the positioning of self-expanding TAVI valve types

    Implantation depth and its influence on complications after TAVI with self-expanding valves

    No full text
    Prior studies in patients with transcatheter aortic valve implantation (TAVI) demonstrated an influence of transcatheter heart valve (THV) position on the occurrence of new conductions disturbances (CD) and paravalvular leakage (PVL) post TAVI in balloon-expandable valves (BEV). Purpose of this study was to investigate the THV implantation depth and its influence on the occurrence of CD and PVL in self-expanding valves (SEV). We performed fusion imaging of pre- and post-procedural computed tomography angiography in 104 TAVI-patients (all with Evolut R) to receive a 3-D reconstruction of the THV within the native annulus region. The THV length below the native annulus was measured for assessment of implantation depth. Electrocardiograms pre-discharge were assessed for conduction disturbances (CD), PVL was determined in transthoracic echocardiography. The mean implantation depth of the THV in the whole cohort was 4.3 ± 3.0 mm. Using the best cut-off of ≥ 4 mm in receiver operating characteristic curve analysis (sensitivity 83.3%, specificity 60.0%) patients with lower THV position developed more new CD after TAVI (68.2 vs. 23.7%, P &amp;lt; 0.001). A deep THV position was identified as the only predictor for new CD after TAVI (odds ratio [CI] 1.312[1.119-1.539], P = 0.001). The implantation depth showed no influence on the grade of PVL (r = 0.052, P = 0.598). In patients with TAVI using the Evolut R SEV, a lower THV positioning (≥ 4 mm length below annulus) was a predictor for new conduction disturbances. In contrast, implantation depth was not associated with the extent of PVL. Prostheses positions of self-expanding valves and their influence on the occurrence of new conduction disturbances and the grade of paravalvular leakage after TAVI

    Prosthesis Position after TAVI with Balloon-Expandable SAPIEN 3 in Bicuspid Aortic Valves

    No full text
    Background: Prior data suggest a correlation between the position of transcatheter heart valves (THV) and the occurrence of complications after transcatheter aortic valve implantation (TAVI) in patients with tricuspid aortic valves (TAV). However, data including a detailed analysis of prosthesis positioning in bicuspid aortic valves (BAV) are limited. Therefore, the purpose of this study was to investigate THV position after TAVI in BAV. Methods: We evaluated the THV position in 50 BAV and 50 TAV patients (all received the balloon-expandable Sapien 3 prosthesis) using fusion imaging of pre- and post-procedural computed tomography angiography. According to the manufacturers’ recommendations, a low implantation position was defined as &gt;30% of the prosthesis below the annulus. Results: THV position was appropriate in the majority of the patients within both groups (90.0% for BAV vs. 96.0% for TAV, p = 0.240). In BAV, we observed a more pronounced THV waist (7.4 ± 4.5% vs. 5.8 ± 3.0%, p = 0.043) and a lower average THV expansion (91.9 ± 12.2% vs. 95.5 ± 2.7% of nominal expansion, p = 0.044). Conclusions: Accurate positioning in relation to the aortic annulus of the TAVI Sapien 3 prosthesis is possible in patients with BAV with results comparable to TAV. However, there is a more pronounced prosthesis waist and a lower average THV expansion in BAV

    Predictors for low TAVI-prosthesis position assessed by fusion imaging of pre- and post-procedural CT angiography

    No full text
    Background!#!Low prosthesis position after transcatheter aortic valve implantation (TAVI) is associated with higher rates of new onset conduction disturbances and permanent pacemaker implantations. Purpose of this study was to investigate possible predictors of a low prosthesis position of the SAPIEN 3 (Edwards Lifesciences, Irvine, California, USA) valve type using fusion imaging of pre- and post-procedural computed tomography angiography (CTA).!##!Methods!#!CTA fusion imaging was performed in 120 TAVI-patients with 3D-reconstruction of the transcatheter heart valve (THV) position within the device landing zone. A low implantation position was defined according to the manufacturer's recommendations as &amp;gt; 30% of the prosthesis below the native annulus plane.!##!Results!#!A low THV position was found in 17 patients (14%). Patients with low THV position had less calcification of the annulus region and a smaller annulus size compared to patients with a normal or high THV position (P = 0.003 and 0.041, respectively). The only independent predictor of a low THV position in multivariate logistic regression analysis was the extent of calcification of the cusp region (odds ratio [CI] 0.842 [0.727-0.976], P = 0.022).!##!Conclusions!#!Fusion imaging of pre-and post-procedural CTA identified reduced calcification of the cusp region as an independent predictor of a low THV position of the SAPIEN 3. This should be considered when planning the TAVI procedure. Correlation of cusp region calcification and prosthesis position after TAVI

    Performance of Computed Tomography Angiography (CTA) for the Diagnosis of Hypo-Attenuated Leaflet Thickening (HALT)

    No full text
    (1) Background: Early hypo-attenuated leaflet thickening (HALT) is diagnosed by computed tomography angiography (CTA) in approximately 15% of patients undergoing transcatheter aortic valve replacement (TAVR). We sought to investigate the diagnostic performance of CTA for the diagnosis of HALT, focusing on timing data assessment within the cardiac cycle. (2) Methods: The study enrolled 50 patients with and 50 without HALT with available post-TAVR-CTA. The primary objective was to compare the diagnostic performance of CTA readings at specific intervals and time points during the cardiac cycle (entire systole, entire diastole, end-systole, and mid-diastole) versus gold standard (consensus reading by two observers based on multiphase full cardiac cycle data sets). (3) Results: 100 CTAs were independently analysed by two observers blinded to clinical characteristics of the study population and the results from the gold standard reading. Sensitivity and specificity for the diagnosis of HALT were 84%/94% in systole, 87%/92% in diastole, 78%/95% at end-systole, and 80%/94% at mid-diastole. End-systole had the highest positive predictive value (0.88) and positive likelihood ratio (36). Cohen’s kappa for interobserver reliability was 0.715 in systole, 0.578 in diastole, 0.650 at end-systole, and 0.517 at mid-diastole. (4) Conclusion: Limiting CTA reading to distinct intervals or time points during the cardiac cycle has good specificity but lowers sensitivity. For a reliable diagnosis of HALT, data sets from a multiphase CTA covering the entire cardiac cycle should be analysed. A double reader approach would be desirable in further studies investigating HALT.Medicine, Faculty ofNon UBCRadiology, Department ofReviewedFacult

    Clinical and cardiac magnetic resonance findings in post-COVID patients referred for suspected myocarditis

    No full text
    Objectives!#!We assessed possible myocardial involvement in previously cardiac healthy post-COVID patients referred for persisting symptoms with suspected myocarditis.!##!Background!#!Prior studies suggested myocardial inflammation in patients with coronavirus-induced disease 2019 (COVID-19). However, the prevalence of cardiac involvement among COVID patients varied between 1.4 and 78%.!##!Methods!#!A total of 56 post-COVID patients without previous heart diseases were included consecutively into this study. All patients had positive antibody titers against SARS-CoV-2. Patients were referred for persistent symptoms such as chest pain/discomfort, shortness of breath, or intolerance to activity. All patients underwent standardized cardiac assessment including electrocardiogram (ECG), cardiac biomarkers, echocardiography, and cardiac magnetic resonance (CMR).!##!Results!#!56 Patients (46 ± 12 years, 54% females) presented 71 ± 66 days after their COVID-19 disease. In most patients, the course of COVID-19 was mild, with hospital treatment being necessary in five (9%). At presentation, patients most often reported persistent fatigue (75%), chest pain (71%), and shortness of breath (66%). Acute myocarditis was confirmed by T1/T2-weighed CMR and elevated NTpro-BNP levels in a single patient (2%). Left ventricular ejection fraction was 56% in this patient. Additional eight patients (14%) showed suspicious CMR findings, including myocardial edema without fibrosis (n = 3), or non-ischemic myocardial injury suggesting previous inflammation (n = 5). However, myocarditis could ultimately not be confirmed according to 2018 Lake Louise criteria; ECG, echo and lab findings were inconspicuous in all eight patients.!##!Conclusions!#!Among 56 post-COVID patients with persistent thoracic complaints final diagnosis of myocarditis could be confirmed in a single patient using CMR