63 research outputs found

    Standardising the clinical assessment of coronal knee laxity

    Get PDF
    Clinical laxity tests are used for assessing knee ligament injuries and for soft tissue balancing in total knee arthroplasty. This study reports the development and validation of a quantitative technique of assessing collateral knee laxity through accurate measurement of potential variables during routine clinical examination. The hypothesis was that standardisation of a clinical stress test would result in a repeatable range of laxity measurements.Non- invasive infrared tracking technology with kinematic registration of joint centres gave real-time measurement of both coronal and sagittal mechanical tibiofemoral alignment. Knee flexion, moment arm and magnitude of the applied force were all measured and standardised. Three clinicians then performed six knee laxity examinations on a single volunteer using a target moment of 18Nm. Standardised laxity measurements had small standard deviations (within 1.1°) for each clinician and similar mean values between clinicians, with the valgus laxity assessment (mean of 3°) being slightly more consistent than varus (means of 4° or 5°).The manual technique of coronal knee laxity assessment was successfully quantified and standardised, leading to a narrow range of measurements (within the accuracy of the measurement system). Minimising the subjective variables of clinical examination could improve current knowledge of soft tissue knee behaviour

    Can a total knee arthroplasty be both rotationally unconstrained and anteroposteriorly stabilised? A pulsed fluoroscopic investigation

    Get PDF
    Objectives: Throughout the 20th Century, it has been postulated that the knee moves on the basis of a four-bar link mechanism composed of the cruciate ligaments, the femur and the tibia. As a consequence, the femur has been thought to roll back with flexion, and total knee arthroplasty (TKA) prostheses have been designed on this basis. Recent work, however, has proposed that at a position of between 0° and 120° the medial femoral condyle does not move anteroposteriorly whereas the lateral femoral condyle tends, but is not obliged, to roll back - a combination of movements which equates to tibial internal/femoral external rotation with flexion. The aim of this paper was to assess if the articular geometry of the GMK Sphere TKA could recreate the natural knee movements in situ/in vivo. Methods: The pattern of knee movement was studied in 15 patients (six male: nine female; one male with bilateral TKAs) with 16 GMK Sphere implants, at a mean age of 66 years (53 to 76) with a mean BMI of 30 kg/m2 (20 to 35). The motions of all 16 knees were observed using pulsed fluoroscopy during a number of weight-bearing and non-weight-bearing static and dynamic activities. Results: During maximally flexed kneeling and lunging activities, the mean tibial internal rotation was 8° (standard deviation (SD) 6). At a mean 112° flexion (SD 16) during lunging, the medial and lateral condyles were a mean of 2 mm (SD 3) and 8 mm (SD 4) posterior to a transverse line passing through the centre of the medial tibial concavity. With a mean flexion of 117° (SD 14) during kneeling, the medial and lateral condyles were a mean of 1 mm (SD 4) anterior and 6 mm (SD 4) posterior to the same line. During dynamic stair and pivoting activities, there was a mean anteroposterior translation of 0 mm to 2 mm of the medial femoral condyle. Backward lateral condylar translation occurred and was linearly related to tibial rotation. Conclusion: The GMK Sphere TKA in our study group shows movements similar in pattern, although reduced in magnitude, to those in recent reports relating to normal knees during several activities. Specifically, little or no translation of the medial femoral condyle was observed during flexion, but there was posterior roll-back of the lateral femoral condyle, equating to tibiofemoral rotation. We conclude that the GMK Sphere is anteroposteriorly stable medially and permits rotation about the medial compartment

    Several clinical interests regarding lung volume reduction surgery for severe emphysema: meta-analysis and systematic review of randomized controlled trials

    Get PDF
    <p>Abstract</p> <p>Objectives</p> <p>We aim to address several clinical interests regarding lung volume reduction surgery (LVRS) for severe emphysema using meta-analysis and systematic review of randomized controlled trials (RCTs).</p> <p>Methods</p> <p>Eight RCTs published from 1999 to 2010 were identified and synthesized to compare the efficacy and safety of LVRS vs conservative medical therapy. One RCT was obtained regarding comparison of median sternotomy (MS) and video-assisted thoracoscopic surgery (VATS). And three RCTs were available evaluating clinical efficacy of using bovine pericardium for buttressing, autologous fibrin sealant and BioGlue, respectively.</p> <p>Results</p> <p>Odds ratio (95%CI), expressed as the mortality of group A (the group underwent LVRS) versus group B (conservative medical therapies), was 5.16(2.84, 9.35) in 3 months, 3(0.94, 9.57) in 6 months, 1.05(0.82, 1.33) in 12 months, respectively. On the 3<sup>rd</sup>, 6<sup>th </sup>and 12<sup>th </sup>month, all lung function indices of group A were improved more significantly as compared with group B. PaO2 and PaCO2 on the 6<sup>th </sup>and 12<sup>th </sup>month showed the same trend. 6MWD of group A on the 6<sup>th </sup>month and 12<sup>th </sup>month were improved significantly than of group B, despite no difference on the 3<sup>rd </sup>month. Quality of life (QOL) of group A was better than of group B in 6 and 12 months. VATS is preferred to MS, due to the earlier recovery and lower cost. And autologous fibrin sealant and BioGlue seems to be the efficacious methods to reduce air leak following LVRS.</p> <p>Conclusions</p> <p>LVRS offers the more benefits regarding survival, lung function, gas exchange, exercise capacity and QOL, despite the higher mortality in initial three postoperative months. LVRS, with the optimization of surgical approach and material for reinforcement of the staple lines, should be recommended to patients suffering from severe heterogeneous emphysema.</p

    Medial Knee Pain in a Runner

    No full text

    Bracing the Unstable Knee

    No full text
    • …
    corecore