93 research outputs found

    Comparative evaluation of diode laser versus argon laser photocoagulation in patients with central serous retinopathy: A pilot, randomized controlled trial [ISRCTN84128484]

    Get PDF
    BACKGROUND: To evaluate the efficacy of diode laser photocoagulation in patients with central serous retinopathy (CSR) and to compare it with the effects of argon green laser. METHODS: Thirty patients with type 1 unilateral CSR were enrolled and evaluated on parameters like best corrected visual acuity (BCVA), direct and indirect ophthalmoscopy, amsler grid for recording scotoma and metamorphopsia, contrast sensitivity using Cambridge low contrast gratings and fluorescein angiography to determine the site of leakage. Patients were randomly assigned into 2 groups according to the statistical random table using sequence generation. In Group 1 (n = 15), diode laser (810 nm) photocoagulation was performed at the site of leakage while in Group 2 (n = 15), eyes were treated with argon green laser (514 nm) using the same laser parameters. Patients were followed up at 4, 8 and 12 weeks after laser. RESULTS: The mean BCVA in group 1 improved from a pre-laser decimal value of 0.29 ± 0.14 to 0.84 ± 0.23 at 4 weeks and 1.06 ± 0.09 at 12 weeks following laser. In group 2, the same improved from 0.32 ± 0.16 to 0.67 ± 0.18 at 4 weeks and 0.98 ± 0.14 at 12 weeks following laser. The improvement in BCVA was significantly better in group 1 (p < 0.0001) at 4 weeks. At 4 weeks following laser, all the patients in group1 were free of scotoma while 6 patients in group 2 had residual scotoma (p < 0.05). The mean contrast sensitivity in group 1 improved from pre-laser value of 98.4 ± 24.77 to 231.33 ± 48.97 at 4 weeks and 306.00 ± 46.57 at 12 weeks following laser. In group 2, the same improved from 130.66 ± 31.95 to 190.66 ± 23.44 at 4 weeks and 215.33 ± 23.25 at 12 weeks. On comparative evaluation, a significantly better (p < 0.001) improvement was noted in group 1. CONCLUSION: Diode laser may be a better alternative to argon green laser whenever laser treatment becomes indicated in patients with central serous retinopathy in terms of faster visual rehabilitation and better contrast sensitivity. In addition, diode laser also has the well-recognized ergonomic and economic advantages

    Design of inhibitors of influenza virus membrane fusion: Synthesis, structure-activity relationship and in vitro antiviral activity of a novel indole series.

    No full text
    The fusion of virus and endosome membranes is an essential early stage in influenza virus infection. The low pH-induced conformational change which promotes the fusogenic activity of the haemagglutinin (HA) is thus an attractive target as an antiviral strategy. The anti-influenza drug Arbidol is representative of a class of antivirals which inhibits HA-mediated membrane fusion by increasing the acid stability of the HA. In this study two series of indole derivatives structurally related to Arbidol were designed and synthesized to further probe the foundation of its antiviral activity and develop the basis for a structure-activity relationship (SAR). Ethyl 5-(hydroxymethyl)-1-methyl-2-(phenysulphanylmethyl)-1. H-indole-3-carboxylate (15) was identified as one of the most potent inhibitors and more potent than Arbidol against certain subtypes of influenza A viruses. In particular, 15 exhibited a much greater affinity and preference for binding group 2 than group 1 HAs, and exerted a greater stabilising effect, in contrast to Arbidol. The results provide the basis for more detailed SAR studies of Arbidol binding to HA; however, the greater affinity for binding HA was not reflected in a comparable increase in antiviral activity of 15, apparently reflecting the complex nature of the antiviral activity of Arbidol and its derivatives
    corecore