69 research outputs found

    PRE-MARKET CLINICAL EVALUATIONS OF INNOVATIVE HIGH-RISK MEDICAL DEVICES IN EUROPE

    Get PDF
    Objectives:High-quality clinical evidence is most often lacking when novel high-risk devices enter the European market. At the same time, a randomized controlled trial (RCT) is often initiated as a requirement for obtaining market access in the US. Should coverage in Europe be postponed until RCT data are available? We studied the premarket clinical evaluation of innovative high-risk medical devices in Europe compared with the US, and with medicines, where appropriate.Methods:The literature and regulatory documents were checked. Representatives from industry, Competent Authorities, Notified Bodies, Ethics Committees, and HTA agencies were consulted. We also discuss patient safety and the transparency of information.Results:In contrast to the US, there is no requirement in Europe to demonstrate the clinical efficacy of high-risk devices in the premarket phase. Patients in Europe can thus have earlier access to a potentially lifesaving device, but at the risk of insufficiently documented efficacy and safety. Variations in the stringency of clinical reviews, both at the level of Notified Bodies and Competent Authorities, do not guarantee patient safety. We tried to document the design of premarket trials in Europe and number of patients exposed, but failed as this information is not made public. Furthermore, the Helsinki Declaration is not followed with respect to the registration and publication of premarket trials.Conclusions:For innovative high-risk devices, new EU legislation should require the premarket demonstration of clinical efficacy and safety, using an RCT if possible, and a transparent clinical review, preferably centralized.</jats:p

    Regional differences in the pattern of airway remodeling following chronic allergen exposure in mice

    Get PDF
    BACKGROUND: Airway remodeling present in the large airways in asthma or asthma models has been associated with airway dysfunction in humans and mice. It is not clear if airways distal to the large conducting airways have similar degrees of airway remodeling following chronic allergen exposure in mice. Our objective was to test the hypothesis that airway remodeling is heterogeneous by optimizing a morphometric technique for distal airways and applying this to mice following chronic exposure to allergen or saline. METHODS: In this study, BALB/c mice were chronically exposed to intranasal allergen or saline. Lung sections were stained for smooth muscle, collagen, and fibronectin content. Airway morphometric analysis of small (0–50000 μm(2)), medium (50000 μm(2)–175000 μm(2)) and large (>175000 μm(2)) airways was based on quantifying the area of positive stain in several defined sub-epithelial regions of interest. Optimization of this technique was based on calculating sample sizes required to detect differences between allergen and saline exposed animals. RESULTS: Following chronic allergen exposure BALB/c mice demonstrate sustained airway hyperresponsiveness. BALB/c mice demonstrate an allergen-induced increase in smooth muscle content throughout all generations of airways, whereas changes in subepithelial collagen and fibronectin content are absent from distal airways. CONCLUSION: We demonstrate for the first time, a systematic objective analysis of allergen induced airway remodeling throughout the tracheobronchial tree in mice. Following chronic allergen exposure, at the time of sustained airway dysfunction, BALB/c mice demonstrate regional differences in the pattern of remodeling. Therefore results obtained from limited regions of lung should not be considered representative of the entire airway tree

    Safety of percutaneous aortic valve insertion. A systematic review

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The technique of percutaneous aortic valve implantation (PAVI) for the treatment of severe aortic stenosis (AS) has been introduced in 2002. Since then, many thousands such devices have worldwide been implanted in patients at high risk for conventional surgery. The procedure related mortality associated with PAVI as reported in published case series is substantial, although the intervention has never been formally compared with standard surgery. The objective of this study was to assess the safety of PAVI, and to compare it with published data reporting the risk associated with conventional aortic valve replacement in high-risk subjects.</p> <p>Methods</p> <p>Studies published in peer reviewed journals and presented at international meetings were searched in major medical databases. Further data were obtained from dedicated websites and through contacts with manufacturers. The following data were extracted: patient characteristics, success rate of valve insertion, operative risk status, early and late all-cause mortality.</p> <p>Results</p> <p>The first PAVI has been performed in 2002. Because of procedural complexity, the original transvenous approach from 2004 on has been replaced by the transarterial and transapical routes. Data originating from nearly 2700 non-transvenous PAVIs were identified. In order to reduce the impact of technical refinements and the procedural learning curve, procedure related safety data from series starting recruitment in April 2007 or later (n = 1975) were focused on. One-month mortality rates range from 6.4 to 7.4% in transfemoral (TF) and 11.6 to 18.6% in transapical (TA) series. Observational data from surgical series in patients with a comparable predicted operative risk, indicate mortality rates that are similar to those in TF PAVI but substantially lower than in TA PAVI. From all identified PAVI series, 6-month mortality rates, reflecting both procedural risk and mortality related to underlying co-morbidities, range from 10.0-25.0% in TF and 26.1-42.8% in TA series. It is not known what the survival of these patients would have been, had they been treated medically or by conventional surgery.</p> <p>Conclusion</p> <p>Safety issues and short-term survival represent a major drawback for the implementation of PAVI, especially for the TA approach. Results from an ongoing randomised controlled trial (RCT) should be awaited before further using this technique in routine clinical practice. In the meantime, both for safety concerns and for ethical reasons, patients should only be subjected to PAVI within the boundaries of such an RCT.</p

    Ring Expansion of Cyclobutylmethylcarbenium Ions to Cyclopentane or Cyclopentene Derivatives and Metal-Promoted Analogous Rearrangements

    Full text link

    Recommendations or mere prose?

    No full text

    Response to letter: Pitfalls in economic analysis

    No full text
    corecore