1,544 research outputs found

    Structure properties of 226{}^{226}Th and 256,258,260{}^{256,258,260}Fm fission fragments: mean field analysis with the Gogny force

    Full text link
    The constrained Hartree-Fock-Bogoliubov method is used with the Gogny interaction D1S to calculate potential energy surfaces of fissioning nuclei 226{}^{226}Th and 256,258,260{}^{256,258,260}Fm up to very large deformations. The constraints employed are the mass quadrupole and octupole moments. In this subspace of collective coordinates, many scission configurations are identified ranging from symmetric to highly asymmetric fragmentations. Corresponding fragment properties at scission are derived yielding fragment deformations, deformation energies, energy partitioning, neutron binding energies at scission, neutron multiplicities, charge polarization and total fragment kinetic energies.Comment: 15 pages, 23 figures, accepted for publication in Phys. Rev. C (2007

    Effect of Loss on Multiplexed Single-Photon Sources

    Full text link
    An on-demand single-photon source is a key requirement for scaling many optical quantum technologies. A promising approach to realize an on-demand single-photon source is to multiplex an array of heralded single-photon sources using an active optical switching network. However, the performance of multiplexed sources is degraded by photon loss in the optical components and the non-unit detection efficiency of the heralding detectors. We provide a theoretical description of a general multiplexed single-photon source with lossy components and derive expressions for the output probabilities of single-photon emission and multi-photon contamination. We apply these expressions to three specific multiplexing source architectures and consider their tradeoffs in design and performance. To assess the effect of lossy components on near- and long-term experimental goals, we simulate the multiplexed sources when used for many-photon state generation under various amounts of component loss. We find that with a multiplexed source composed of switches with ~0.2-0.4 dB loss and high efficiency number-resolving detectors, a single-photon source capable of efficiently producing 20-40 photon states with low multi-photon contamination is possible, offering the possibility of unlocking new classes of experiments and technologies.Comment: Journal versio

    Vacuum Polarization Effects in the Lorentz and PCT Violating Electrodynamics

    Full text link
    In this work we report new results concerning the question of dynamical mass generation in the Lorentz and PCT violating quantum electrodynamics. A one loop calculation for the vacuum polarization tensor is presented. The electron propagator, "dressed" by a Lorentz breaking extra term in the fermion Lagrangian density, is approximated by its first order: this scheme is shown to break gauge invariance. Then we rather consider a full calculation to second order in the Lorentz breaking parameter: we recover gauge invariance and use the Schwinger-Dyson equation to discuss the full photon propagator. This allows a discussion on a possible photon mass shift as well as measurable, observable physical consequences, such as the Lamb-shift.Comment: Latex file, 19 pages, no figures, includes PACS number

    Charon's radius and density from the combined data sets of the 2005 July 11 occultation

    Full text link
    The 2005 July 11 C313.2 stellar occultation by Charon was observed by three separate research groups, including our own, at observatories throughout South America. Here, the published timings from the three data sets have been combined to more accurately determine the mean radius of Charon: 606.0 +/- 1.5 km. Our analysis indicates that a slight oblateness in the body (0.006 +/- 0.003) best matches the data, with a confidence level of 86%. The oblateness has a pole position angle of 71.4 deg +/- 10.4 deg and is consistent with Charon's pole position angle of 67 deg. Charon's mean radius corresponds to a bulk density of 1.63 +/- 0.07 g/cm3, which is significantly less than Pluto's (1.92 +/- 0.12 g/cm3). This density differential favors an impact formation scenario for the system in which at least one of the impactors was differentiated. Finally, unexplained differences between chord timings measured at Cerro Pachon and the rest of the data set could be indicative of a depression as deep as 7 km on Charon's limb.Comment: 25 pages including 4 tables and 2 figures. Submitted to the Astronomical Journal on 2006 Feb 0

    Perfluorochemical (PFC) liquid enhances recombinant adenovirus vector-mediated viral interleukin-10 (AdvIL-10) expression in rodent lung

    Get PDF
    Adenovirus and cationic liposome mediated transfer of Interleukin-10 (IL-10), a potent anti-inflammatory cytokine, has been shown to decrease pro-inflammatory cytokine levels and overall lung inflammation in models of lung transplantation and injury. Limitations to current approaches of IL-10 gene therapy include poor vector delivery methods and pro-inflammatory properties of human IL-10 under certain conditions. We hypothesize that using perfluorochemical (PFC) liquid to deliver the highly homologous viral IL-10 (vIL-10), which is predominantly anti-inflammatory with minimal pro-inflammatory activities, can potentially be a more effective strategy to combat inflammatory lung diseases. In this study, we compare the use of PFC liquid versus aerosolized method to deliver adenovirus encoding the vIL-10 gene (AdvIL-10) in C57Bl6 mice. Detectable vIL-10 levels were measured from bronchoalveolar lavage fluid and lung homogenates at one, four, ten and thirty days after AdvIL-10. Furthermore, we determined if use of PFC liquid could allow for the use of a lower dose of AdvIL-10 by comparing the levels of detectable vIL-10 at different doses of AdvIL-10 delivered +/- PFC liquid. Results showed that PFC liquid enhanced detectable vIL-10 by up to ten fold and that PFC liquid allowed the use of ten-fold less vector. PFC liquid increased detectable vIL-10 in lung homogenates at all time points; however, the increase in detectable vIL-10 in BAL fluid peaked at four days and was no longer evident by thirty days after intratracheal instillation. In summary, this is the first report utilizing PFC liquid to enhance the delivery of a potentially therapeutic molecule, vIL-10. We believe this strategy can be used to perform future studies on the use of the predominantly anti-inflammatory vIL-10 to treat inflammatory lung diseases

    Active Temporal Multiplexing of Photons

    Get PDF
    Photonic qubits constitute a leading platform to disruptive quantum technologies due to their unique low-noise properties. The cost of the photonic approach is the non-deterministic nature of many of the processes, including single-photon generation, which arises from parametric sources and negligible interaction between photons. Active temporal multiplexing - repeating a generation process in time and rerouting to single modes using an optical switching network - is a promising approach to overcome this challenge and will likely be essential for large-scale applications with greatly reduced resource complexity and system sizes. Requirements include the precise synchronization of a system of low-loss switches, delay lines, fast photon detectors, and feed-forward. Here we demonstrate temporal multiplexing of 8 'bins' from a double-passed heralded photon source and observe an increase in the heralding and heralded photon rates. This system points the way to harnessing temporal multiplexing in quantum technologies, from single-photon sources to large-scale computation.Comment: Minor revision

    Witnessing eigenstates for quantum simulation of Hamiltonian spectra

    Get PDF
    The efficient calculation of Hamiltonian spectra, a problem often intractable on classical machines, can find application in many fields, from physics to chemistry. Here, we introduce the concept of an "eigenstate witness" and through it provide a new quantum approach which combines variational methods and phase estimation to approximate eigenvalues for both ground and excited states. This protocol is experimentally verified on a programmable silicon quantum photonic chip, a mass-manufacturable platform, which embeds entangled state generation, arbitrary controlled-unitary operations, and projective measurements. Both ground and excited states are experimentally found with fidelities >99%, and their eigenvalues are estimated with 32-bits of precision. We also investigate and discuss the scalability of the approach and study its performance through numerical simulations of more complex Hamiltonians. This result shows promising progress towards quantum chemistry on quantum computers.Comment: 9 pages, 4 figures, plus Supplementary Material [New version with minor typos corrected.

    R-values in Low Energy e^+e^- Annihilation

    Get PDF
    This presentation briefly summarizes the recent measurements of R-values in low energy e^+e^- annihilation. The new experiments aimed at reducing the uncertainties in R-values and performed with the upgraded Beijing Spectrometer (BESII) at Beijing Electron Positron Collider (BEPC) in Beijing and with CMD-2 and SND at VEEP-2M in Novosibirsk are reviewed and discussed.Comment: 17 pages, 10 figures, invited presentation at the XIX International Symposium on Lepton and Photon Interactions at High Energy, Stanford University, August 199

    Measurement of the Surface Gravity of η\eta Boo

    Full text link
    Direct angular size measurements of the G0IV subgiant η\eta Boo from the Palomar Testbed Interferometer are presented, with limb-darkened angular size of θLD=2.18940.0140+0.0055\theta_{LD}= 2.1894^{+0.0055}_{-0.0140} mas, which indicate a linear radius of R=2.672±0.028RR=2.672 \pm 0.028 R_\odot. A bolometric flux estimate of FBOL=22.1±0.28×107F_{BOL} = 22.1 \pm 0.28\times 10^{-7} erg cm2^{-2}s1^{-1} is computed, which indicates an effective temperature of TEFF=6100±28T_{EFF}=6100 \pm 28 K and luminosity of L=8.89±0.16LL = 8.89 \pm 0.16 L_\odot for this object. Similar data are established for a check star, HD 121860. The η\eta Boo results are compared to, and confirm, similar parameters established by the {\it MOST} asteroseismology satellite. In conjunction with the mass estimate from the {\it MOST} investigation, a surface gravity of logg=3.817±0.016\log g=3.817 \pm 0.016 [cm s2^{-2}] is established for η\eta Boo.Comment: To appear in March 1, 2007 ApJ v657 n
    corecore