7 research outputs found

    Efficacy of beta radiation in prevention of post-angioplasty restenosis

    Get PDF
    Restenosis remains a major limitation of coronary angioplasty in spite of major advances in techniques and technology. Recent studies have demonstrated that ionizing radiation may limit the degree of this problem. Gamma radiation has been shown to be effective in reducing in stent restenosis in humans, and beta radiation following encouraging results in animals has been shown to be feasible in humans. The objective of this study was to assess the feasibility of a 5 F non-centered catheter to deliver beta radiation emitting seeds to the lesion site post angioplasty and its effect on restenosis. Following successful angioplasty, patients were randomized to treatment with 12, 14 or 16 Gy at the angioplasty site. This was delivered with a 5 F non-centered catheter. Twelve beta radiation emitting seeds (90Sr/Y) were delivered to an area 3 cm in length to cover the angioplasty site. Angiographic follow-up was performed at 6 months. Baseline and follow-up angiograms were performed by blinded investigators at a core laboratory. This interim report comprises the first 35 patients to complete 6-month angiographic follow-up. There were no major radiation incidents. Four patients had evidence of angiographic restenosis. The MLD (mm) and percent stenosis were 0.77 +/- 0.27/72.5 +/- 8.6 pre angioplasty, 2.08 +/- 0.4/25.7 +/- 9.8 post angioplasty and radiation and 2.05 +/- 0.59/25.7 +/- 19.8 at follow-up respectively. CONCLUSION: Beta radiation can be feasibly and safely delivered post coronary angioplasty with a very encouraging reduction of restenosis

    Low molecular weight heparin (reviparin) in percutaneous transluminal coronary angioplasty. Results of a randomized, double-blind, unfractionated heparin and placebo-controlled, multicenter trial (REDUCE trial)

    Get PDF
    Objectives. The specific objective of the REDUCE trial was to evaluate the effect of low molecular weight heparin on the incidence and occurrence of restenosis in patients undergoing percutaneous transluminal coronary angioplasty (PTCA). Background. Unfractionated heparin and its low molecular weight fragments possess antiproliferative effects and have been shown to reduce neointimal smooth muscle cell migration and proliferation in response to vascular injury in experimental studies. Methods. The REDUCE trial is an international prospective, randomized, double-blind, multicenter study. Twenty-six centers in Europe and Canada enrolled 625 patients with single-lesion coronary artery obstructions suitable for PTCA. Three hundred six patients received reviparin as a 7,000-U bolus before PTCA, followed by 10,500 U as an infusion over 24 h and then twice-daily 3,500-U subcutaneous application for 28 days. The 306 patients in the control group received a bolus of 10,000 U o

    First international new intravascular rigid-flex endovascular stent study (FINESS): Clinical and angiographic results after elective and urgent stent implantation

    Get PDF
    Objectives. The purpose of this study was to determine the feasibility, safety and efficacy of elective and urgent deployment of the new intravascular rigid-flex (NIR) stent in patients with coronary artery disease. Background. Stent implantation has been shown to be effective in the treatment of focal, new coronary stenoses and in restoring coronary flow after coronary dissection and abrupt vessel closure. However, currently available stents either lack flexibility, hindering navigation through tortuous arteries, or lack axial strength, resulting in suboptimal scaffolding of the vessel. The unique transforming multicellular design of the NIR stent appears to provide both longitudinal flexibility and radial strength. Methods. NIR stent implantation was attempted in 255 patients (341 lesions) enrolled prospectively in a multicenter international registry from December 1995 through March 1996. Nine-, 16- and 32-mm long NIR stents were manually crimped onto coronary balloons and deployed in native coronary (94%) and saphenous vein graft (6%) lesions. Seventy-four percent of patients underwent elective stenting for primary or restenotic lesions, 21% for a suboptimal angioplasty result and 5% for threatened or abrupt vessel closure. Fifty-two percent of patients presented with unstable angina, 48% had a previous myocardial infarction, and 45% had multivessel disease. Coronary lesions were frequently complex, occurring in relatively small arteries (mean [±SD] reference diameter 2.8 ± 0.6 mm). Patients were followed up for 6 months for the occurrence of major adverse cardiovascular events. Results. Stent deployment was accomplished in 98% of lesions. Mean minimal lumen diameter increased by 1.51 ± 0.51 mm (from 1.09 ± 0.43 mm before to 2.60 ± 0.50 mm after the procedure). Mean percent diameter stenosis decreased from 61 ± 13% before to 17 ± 7% after intervention. A successful interventional procedure with <50% diameter stenosis of all treatment site lesions and no major adverse cardiac events within 30 days occurred in 95% of patients. Event-free survival at 6 months was 82%. Ninety-four percent of surviving patients were either asymptomatic or had mild stable angina at 6 month follow-up. Conclusions. Despite unfavorable clinical and angiographic characteristics of the majority of patients enrolled, the acute angiographic results and early clinical outcome after NIR stent deployment were very promising. A prospective, randomized trial comparing the NIR stent with other currently available stents appears warranted
    corecore