19 research outputs found
Reducing Pulse Oximetry False Alarms Without Missing Life-Threatening Events
Alarm fatigue has been increasingly recognized as one of the most significant problems in the hospital environment. One of the major causes is the excessive number of false physiologic monitor alarms. An underlying problem is the inefficient traditional threshold alarm system for physiologic parameters such as low blood oxygen saturation (SpO2). In this paper, we propose a robust classification procedure based on the AdaBoost algorithm with reject option that can identify and silence false SpO2 alarms, while ensuring zero misclassified clinically significant alarms. Alarms and vital signs related to SpO2 such as heart rate and pulse rate, within monitoring interval are extracted into different numerical features for the classifier. We propose a variant of AdaBoost with reject option by allowing a third decision (i.e., reject) expressing doubt. Weighted outputs of each weak classifier are input to a softmax function optimizing to satisfy a desired false negative rate upper bound while minimizing false positive rate and indecision rate. We evaluate the proposed classifier using a dataset collected from 100 hospitalized children at Children\u27s Hospital of Philadelphia and show that the classifier can silence 23.12% of false SpO2 alarms without missing any clinically significant alarms
Eliminating Monitor Overuse (EMO) Type III Effectiveness-Deimplementation Cluster-Randomized Trial: Statistical Analysis Plan
Background: Deimplementing overused health interventions is essential to maximizing quality and value while minimizing harm, waste, and inefficiencies. Three national guidelines discourage continuous pulse oximetry (SpO2) monitoring in children who are not receiving supplemental oxygen, but the guideline-discordant practice remains prevalent, making it a prime target for deimplementation. This paper details the statistical analysis plan for the Eliminating Monitor Overuse (EMO) SpO2 trial, which compares the effect of two competing deimplementation strategies (unlearning only vs. unlearning plus substitution) on the sustainment of deimplementation of SpO2 monitoring in children with bronchiolitis who are in room air.
Methods: The EMO Trial is a hybrid type 3 effectiveness-deimplementation trial with a longitudinal cluster-randomized design, conducted in Pediatric Research in Inpatient Settings Network hospitals. The primary outcome is deimplementation sustainment, analyzed as a longitudinal difference-in-differences comparison between study arms. This analysis will use generalized hierarchical mixed-effects models for longitudinal clustering outcomes. Secondary outcomes include the length of hospital stay and oxygen supplementation duration, modeled using linear mixed-effects regressions. Using the well-established counterfactual approach, we will also perform a mediation analysis of hospital-level mechanistic measures on the association between the deimplementation strategy and the sustainment outcome.
Discussion: We anticipate that the EMO Trial will advance the science of deimplementation by providing new insights into the processes, mechanisms, and likelihood of sustained practice change using rigorously designed deimplementation strategies. This pre-specified statistical analysis plan will mitigate reporting bias and support data-driven approaches
Rapid Response Systems 20 Years Later: New Approaches, Old Challenges
In 1990, Schein and colleagues changed the paradigm
of in-hospital cardiopulmonary arrest. Their report,
“Clinical Antecedents to In-Hospital Cardiopulmonary
Arrest,” provided evidence from adults suggesting
that many arrests could have been prevented if existing
signs of deterioration were identified, interpreted,
communicated, and responded to appropriately.1 Five
years later, Liverpool Hospital published the first report
of a rapid response system.2 This marked the start
of a patient safety movement that spread quickly to
children’s hospitals.3
Rapid response systems aim to improve the detection
and management of deterioration in hospitalized
patients. They combine tools to help clinicians identify
deterioration with medical emergency teams that can
be summoned to the bedsides of ill patients. Rapid response
system implementation was associated with
reductions in cardiopulmonary arrests (relative risk [RR],
0.62 [95% CI, 0.46-0.84]) and mortality (RR, 0.79
[95%CI,0.63-0.98]) in a recentmeta-analysis,4 and reversed
a trend of increasing critical deterioration events
(a more proximate outcome) in a quasi-experimental
study.5Duein part tomountingevidence,commonsense
appeal, and their inclusion in major initiatives like the
Institute for Healthcare Improvement’s 5 Million Lives
Campaign, rapid response systems are now nearly universally
present in hospitals worldwide.
Unfortunately, rapid responsesystemshavenotfully
solved the problem they targeted 20years ago, and, despite
progress, the challenges in pediatrics remain complex.
Children still deteriorate on hospital wards, and
40% or more of these events may be preventable.6
There is an opportunity to renew the enthusiasm that
surrounded the first generation of rapid response systemwork,
which focused primarilyonthe medicalemergency
team response, to pursue the more difficultwork
of optimizing the identification of deteriorating children.
Below we propose a set of recommendations for
a research agenda aimed at addressing this challenge. [Introduction
Recommended from our members
Critical care nurses' clinical reasoning about physiologic monitor alarm customisation: An interpretive descriptive study
Aims and objectives To explore clinical reasoning about alarm customisation among nurses in intensive care units. Background Critical care nurses are responsible for detecting and rapidly acting upon changes in patients' clinical condition. Nurses use medical devices including bedside physiologic monitors to assist them in their practice. Customising alarm settings on these devices can help nurses better monitor their patients and reduce the number of clinically irrelevant alarms. As a result, customisation may also help address the problem of alarm fatigue. However, little is known about nurses' clinical reasoning with respect to customising physiologic monitor alarm settings. Design This article is an in-depth report of the qualitative arm of a mixed methods study conducted using an interpretive descriptive methodological approach. Methods Twenty-seven nurses were purposively sampled from three intensive care units in an academic medical centre. Semi-structured interviews were conducted by telephone and were analysed using thematic analysis. Consolidated Criteria for Reporting Qualitative Research (COREQ) reporting guidelines were used. Results Four themes were identified from the interview data: unit alarm culture and context, nurse attributes, motivation to customise and customisation "know-how." A conceptual model demonstrating the relationship of these themes was developed to portray the factors that affect nurses' customisation of alarms. Conclusions In addition to drawing on clinical data, nurses customised physiologic monitor alarms based on their level of clinical expertise and comfort. Nurses were influenced by the alarm culture on their clinical unit and colleagues' and patients' responses to alarms, as well as their own technical understanding of the physiologic monitors. Relevance to clinical practice The results of this study can be used to design strategies to support the application of clinical reasoning to alarm management, which may contribute to more appropriate alarm customisation practices and improvements in safety.Sigma Theta Tau International Doris K Bloch award; Connecticut Nurses' Association12 month embargo; published online: 2 April 2019This item from the UA Faculty Publications collection is made available by the University of Arizona with support from the University of Arizona Libraries. If you have questions, please contact us at [email protected]