    Clinically feasible semi-automatic workflows for measuring metabolically active tumour volume in metastatic melanoma

    Get PDF
    PURPOSE: Metabolically active tumour volume (MATV) is a potential quantitative positron emission tomography (PET) imaging biomarker in melanoma. Accumulating data indicate that low MATV may predict increased chance of response to immunotherapy and overall survival. However, metastatic melanoma can present with numerous (small) tumour lesions, making manual tumour segmentation time-consuming. The aim of this study was to evaluate multiple semi-automatic segmentation workflows to determine reliability and reproducibility of MATV measurements in patients with metastatic melanoma. METHODS: An existing cohort of 64 adult patients with histologically proven metastatic melanoma was used in this study. 18F-FDG PET/CT diagnostic baseline images were acquired using a European Association of Nuclear Medicine (EANM) Research Limited-accredited Siemens Biograph mCT PET/CT system (Siemens Healthineers, Knoxville, USA). PET data were analysed using manual, gradient-based segmentation and five different semi-automatic methods: three direct PET image-derived delineations (41MAX, A50P and SUV40) and two based on a majority-vote approach (MV2 and MV3), without and with (suffix '+') manual lesion addition. Correlation between the different segmentation methods and their respective associations with overall survival was assessed. RESULTS: Correlation between the MATVs derived by the manual segmentation and semi-automated tumour segmentations ranged from R2 = 0.41 for A50P to R2 = 0.85 for SUV40+ and MV2+, respectively. Manual MATV segmentation did not differ significantly from the semi-automatic methods SUV40 (∆MATV mean ± SD 0.08 ± 0.60 mL, P = 0.303), SUV40+ (∆MATV - 0.10 ± 0.51 mL, P = 0.126), MV2+ (∆MATV - 0.09 ± 0.62 mL, P = 0.252) and MV3+ (∆MATV - 0.03 ± 0.55 mL, P = 0.615). Log-rank tests showed statistically significant overall survival differences between above and below median MATV patients for all segmentation methods with areas under the ROC curves of 0.806 for manual segmentation and between 0.756 [41MAX] and 0.807 [MV3+] for semi-automatic segmentations. CONCLUSIONS: Simple and fast semi-automated FDG PET segmentation workflows yield accurate and reproducible MATV measurements that correlate well with manual segmentation in metastatic melanoma. The most readily applicable and user-friendly SUV40 method allows feasible MATV measurement in prospective multicentre studies required for validation of this potential PET imaging biomarker for clinical use

    Timelines of the "free-particle" and "fixed-particle" models of stone-formation: theoretical and experimental investigations

    Get PDF
    Two major theories on renal stone formation will be reviewed, the “free-particle” and “fixed-particle” mechanisms. These theories combine data on intrinsic factors (inborn metabolic errors), extrinsic factors (diet), renal cell responses and the physico-chemistry and biochemistry of urine into mechanisms of stone formation. This paper describes the specific role of time in both mechanisms. The timeline of crystal- and stone formation was deducted from literature data and was measured for two stones using radioisotope decay analysis. The stones of similar size and composition showed, respectively, a timeline of a few years and a development that took decades. In combination with data on stone architecture and patient characteristics these timelines are explained using the free-particle and fixed-particle mechanisms. Consideration of the timeline of stone formation has clinical implications. We conclude that the fixed-particle mechanism can be a slow process where decades pass between the first formation of a precipitate in the renal interstitium and the clinical presentation of the stone. Added to the fact that the mechanism of this initial precipitation is still ill defined, the conditions that started fixed-particle stone formation in an individual patient can be obscure. Blood and urine analysis in such patients does not necessarily reveal the individual’s risk for recurrence as lifestyle may have changed over time. This is in fact what defines the so-called idiopathic stoneformers. For these patients, prevention of outgrowth of previously formed precipitates, papillary plaques, may be more relevant than prevention of new plaque formation. In contrast, a patient who has formed a stone in a relatively short time through the free-particle mechanism is more likely to show abnormal values in blood and urine that explain the starting event of stone formation. In these patients, measurement of such values provides useful information to guide preventive measures. © 2016, The Author(s)

    Repeatability of quantitative18F-FLT uptake measurements in solid tumors: an individual patient data multi-center meta-analysis

    Get PDF
    INTRODUCTION: 3'-deoxy-3'-[18F]fluorothymidine (18F-FLT) positron emission tomography (PET) provides a non-invasive method to assess cellular proliferation and response to antitumor therapy. Quantitative18F-FLT uptake metrics are being used for evaluation of proliferative response in investigational setting, however multi-center repeatability needs to be established. The aim of this study was to determine the repeatability of18F-FLT tumor uptake metrics by re-analyzing individual patient data from previously published reports using the same tumor segmentation method and repeatability metrics across cohorts. METHODS: A systematic search in PubMed, EMBASE.com and the Cochrane Library from inception-October 2016 yielded five18F-FLT repeatability cohorts in solid tumors.18F-FLT avid lesions were delineated using a 50% isocontour adapted for local background on test and retest scans. SUVmax, SUVmean, SUVpeak, proliferative volume and total lesion uptake (TLU) were calculated. Repeatability was assessed using the repeatability coefficient (RC = 1.96 × SD of test-retest differences), linear regression analysis, and the intra-class correlation coefficient (ICC). The impact of different lesion selection criteria was also evaluated. RESULTS: Images from four cohorts containing 30 patients with 52 lesions were obtained and analyzed (ten in breast cancer, nine in head and neck squamous cell carcinoma, and 33 in non-small cell lung cancer patients). A good correlation was found between test-retest data for all18F-FLT uptake metrics (R2 ≥ 0.93; ICC ≥ 0.96). Best repeatability was found for SUVpeak(RC: 23.1%), without significant differences in RC between different SUV metrics. Repeatability of proliferative volume (RC: 36.0%) and TLU (RC: 36.4%) was worse than SUV. Lesion selection methods based on SUVmax ≥ 4.0 improved the repeatability of volumetric metrics (RC: 26-28%), but did not affect the repeatability of SUV metrics. CONCLUSIONS: In multi-center studies, differences ≥ 25% in18F-FLT SUV metrics likely represent a true change in tumor uptake. Larger differences are required for FLT metrics comprising volume estimates when no lesion selection criteria are applied

    Image Derived Input Functions: Effects of Motion on Tracer Kinetic Analyses

    Get PDF
    Purpose: To quantify the effects of motion affected image-derived input functions (IDIF) on the outcome of tracer kinetic analyses. Procedures: Two simulation studies, one based on high and the other on low cortical uptake, were performed. Different degrees of rotational and axial translational motion were added to the final frames of simulated dynamic positron emission tomography scans. Extracted IDIFs from motion affected simulated scans were compared to original IDIFs and to outcome of tracer kinetic analysis (volume of distribution, V T). Results: Differences in IDIF values of up to 239 % were found for the last frames. Patient motion of more than 6 ° or 5 mm resulted in at least 10 % higher or lower VT values for the high cortical tracer. Conclusion: The degrees of motion studied are commonly observed in clinical studies and hamper the extraction of accurate IDIFs. Therefore, it is essential to ensure that patient motion is minimal and corrected for

    Impact of PET/CT system, reconstruction protocol, data analysis method, and repositioning on PET/CT precision:An experimental evaluation using an oncology and brain phantom

    Get PDF
    Purpose: In longitudinal oncological and brain PET/CT studies, it is important to understand the repeatability of quantitative PET metrics in order to assess change in tracer uptake. The present studies were performed in order to assess precision as function of PET/CT system, reconstruction protocol, analysis method, scan duration (or image noise), and repositioning in the field of view. Methods: Multiple (repeated) scans have been performed using a NEMA image quality (IQ) phantom and a 3D Hoffman brain phantom filled with F-18 solutions on two systems. Studies were performed with and without randomly (<2 cm) repositioning the phantom and all scans (12 replicates for IQ phantom and 10 replicates for Hoffman brain phantom) were performed at equal count statistics. For the NEMA IQ phantom, we studied the recovery coefficients (RC) of the maximum (SUVmax), peak (SUVpeak), and mean (SUVmean) uptake in each sphere as a function of experimental conditions (noise level, reconstruction settings, and phantom repositioning). For the 3D Hoffman phantom, the mean activity concentration was determined within several volumes of interest and activity recovery and its precision was studied as function of experimental conditions. Results: The impact of phantom repositioning on RC precision was mainly seen on the Philips Ingenuity PET/CT, especially in the case of smaller spheres (<17 mm diameter, P <0.05). This effect was much smaller for the Siemens Biograph system. When exploring SUVmax, SUVpeak, or SUVmean of the spheres in the NEMA IQ phantom, it was observed that precision depended on phantom repositioning, reconstruction algorithm, and scan duration, with SUVmax being most and SUVpeak least sensitive to phantom repositioning. For the brain phantom, regional averaged SUVs were only minimally affected by phantom repositioning (<2 cm). Conclusion: The precision of quantitative PET metrics depends on the combination of reconstruction protocol, data analysis methods and scan duration (scan statistics). Moreover, precision was also affected by phantom repositioning but its impact depended on the data analysis method in combination with the reconstructed voxel size (tissue fraction effect). This study suggests that for oncological PET studies the use of SUVpeak may be preferred over SUVmax because SUVpeak is less sensitive to patient repositioning/tumor sampling. (c) 2017 The Authors. Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine

    Can radiographers be trained to triage CT colonography for extracolonic findings?

    Get PDF
    OBJECTIVES: Radiographers have been shown to be capable CT colonography observers. We evaluated whether radiographers can be trained to triage screening CT colonography for extracolonic findings. METHODS: Eight radiographers participated in a structured training program. They subsequently evaluated extracolonic findings in 280 low-dose CT colonograms (cases). This dataset contained 66 cases with possibly important findings (E3) and 27 cases with probably important findings (E4) [classification based on the highest classified finding (C-RADS)]. The first 40 and last 40 CT colonograms were identical test cases. Immediate feedback was given after each reading, except for test cases. Radiographers triaged cases based on C-RADS classification and indicated the need for a radiologist read. We constructed learning curves for correct case triaging by calculating moving averages. RESULTS: In the final test series, 84/120 (70 %) cases with E3 or E4 findings and 139/200 (70 %) without E3 or E4 findings were correctly triaged. Correct identification of cases with E3 findings improved with training from 46/88 (52 %) to 62/88 (70 %) (P < 0.0001) but not for E4 findings [both 22/32 (69 %) P = 1.00]. CONCLUSIONS: Radiographers improve after training in correctly triaging extracolonic findings at CT colonography but do not reach a high enough accuracy to consider their structural involvement in screening. KEY POINTS: • Radiographers were trained to triage CT colonography for extracolonic findings. • After training, radiographers improved sensitivity for likely unimportant findings. • After training, radiographers did not improve sensitivity for possibly important findings. • Radiographers should probably not be expected to identify all extracolonic findings

    EANM/EARL harmonization strategies in PET quantification: from daily practice to multicentre oncological studies

    Get PDF
    Quantitative positron emission tomography/computed tomography (PET/CT) can be used as diagnostic or prognostic tools (i.e. single measurement) or for therapy monitoring (i.e. longitudinal studies) in multicentre studies. Use of quantitative parameters, such as standardized uptake values (SUVs), metabolic active tumor volumes (MATVs) or total lesion glycolysis (TLG), in a multicenter setting requires that these parameters be comparable among patients and sites, regardless of the PET/CT system used. This review describes the motivations and the methodologies for quantitative PET/ CT performance harmonization with emphasis on the EANM Research Ltd. (EARL) Fluorodeoxyglucose (FDG) PET/CT accreditation program, one of the international harmonization programs aiming at using FDG PET as a quantitative imaging biomarker. In addition, future accreditation initiatives will be discussed. The validation of the EARL accreditation program to harmonize SUVs and MATVs is described in a wide range of tumor types, with focus on therapy assessment using either the European Organization for Research and Treatment of Cancer (EORTC) criteria or PET Evaluation Response Criteria in Solid Tumors (PERCIST), as well as liver-based scales such as the Deauville score. Finally, also presented in this paper are the results from a survey across 51 EARL-accredited centers reporting how the program was implemented and its impact on daily routine and in clinical trials, harmonization of new metrics such as MATV and heterogeneity features

    Feasibility of state of the art PET/CT systems performance harmonisation

    Get PDF
    Purpose The objective of this study was to explore the feasibility of harmonising performance for PET/CT systems equipped with time-of-flight (ToF) and resolution modelling/point spread function (PSF) technologies. A second aim was producing a working prototype of new harmonising criteria with higher contrast recoveries than current EARL standards using various SUV metrics. Methods Four PET/CT systems with both ToF and PSF capabilities from three major vendors were used to acquire and reconstruct images of the NEMA NU2-2007 body phantom filled conforming EANM EARL guidelines. A total of 15 reconstruction parameter sets of varying pixel size, post filtering and reconstruction type, with three different acquisition durations were used to compare the quantitative performance of the systems. A target range for recovery curves was established such that it would accommodate the highest matching recoveries from all investigated systems. These updated criteria were validated on 18 additional scanners from 16 sites in order to demonstrate the scanners' ability to meet the new target range. Results Each of the four systems was found to be capable of producing harmonising reconstructions with similar recovery curves. The five reconstruction parameter sets producing harmonising results significantly increased SUVmean (25%) and SUVmax (26%) contrast recoveries compared with current EARL specifications. Additional prospective validation performed on 18 scanners from 16 EARL accredited sites demonstrated the feasibility of updated harmonising specifications. SUVpeak was found to significantly reduce the variability in quantitative results while producing lower recoveries in smaller ( Conclusions Harmonising PET/CT systems with ToF and PSF technologies from different vendors was found to be feasible. The harmonisation of such systems would require an update to the current multicentre accreditation program EARL in order to accommodate higher recoveries. SUVpeak should be further investigated as a noise resistant alternative quantitative metric to SUVmax