35 research outputs found
Unusual right ventricle outflow tract obstruction in Dacron valved conduits
Abstract Various biological valved conduits have been used to treat the obstructions of the right ventricle. These conduits have different rates and etiologies for conduit stenosis during early- and long-term follow-up. We report on three cases of unusual intra-luminal peeling of a Dacron conduit leading to various types of conduit obstruction
Temporal relationship between instantaneous pressure gradients and peak‐to‐peak systolic ejection gradient in congenital aortic stenosis
ObjectiveWe sought to identify a time during cardiac ejection when the instantaneous pressure gradient (IPG) correlated best, and near unity, with peak‐to‐peak systolic ejection gradient (PPSG) in patients with congenital aortic stenosis. Noninvasive echocardiographic measurement of IPG has limited correlation with cardiac catheterization measured PPSG across the spectrum of disease severity of congenital aortic stenosis. A major contributor is the observation that these measures are inherently different with a variable relationship dependent on the degree of stenosis.DesignHemodynamic data from cardiac catheterizations utilizing simultaneous pressure measurements from the left ventricle (LV) and ascending aorta (AAo) in patients with congenital valvar aortic stenosis was retrospectively reviewed over the past 5 years. The cardiac cycle was standardized for all patients using the percentage of total LV ejection time (ET). Instantaneous gradient at 5% intervals of ET were compared to PPSG using linear regression and Bland‐Altman analysis.ResultsA total of 22 patients underwent catheterization at a median age of 13.7 years (interquartile range [IQR] 10.3‐18.0) and median weight of 51.1 kg (IQR 34.2‐71.6). The PPSG was 46.5 ± 12.6 mm Hg (mean ± SD) and correlated suboptimally with the maximum and mean IPG. The midsystolic IPG (occurring at 50% of ET) had the strongest correlation with the PPSG (PPSG = 0.97(IPG50%)–1.12, R2 = 0.88), while the IPG at 55% of ET was closest to unity (PPSG = 0.997(IPG55%)–1.17, R2 = 0.87).ConclusionsThe commonly measured maximum and mean IPG are suboptimal estimates of the PPSG in congenital aortic stenosis. Using catheter‐based data, IPG at 50%–55% of ejection correlates well with PPSG. This may allow for a more accurate estimation of PPSG via noninvasive assessment of IPG.Peer Reviewedhttps://deepblue.lib.umich.edu/bitstream/2027.42/140042/1/chd12514.pdfhttps://deepblue.lib.umich.edu/bitstream/2027.42/140042/2/chd12514_am.pd
Prognostic significance of new onset ascites in patients with pancreatic cancer
BACKGROUND: The purpose of this study was to determine risk factors for development of malignant ascites and its prognostic significance in patients with pancreatic cancer. METHODS: A prospective database was queried to identify patients with pancreatic cancer who develop ascites. Stage at presentation, size, and location of primary tumor, treatment received and length of survival after onset of ascites were determined. RESULTS: A total of 15 patients were identified. Of which 4 patients (1 stage II, 3 stage III) underwent pancreaticoduodenectomy and manifested with ascites 2, 3, 24 and 47 months after surgery (tumor size 2.9 ± 1.32 cm). All but one of the remaining 11 patients (tumor size 4.4 ± 3.38 cm) presented with metastatic disease, and all developed malignant ascites 9 months after diagnosis, dying 2 months later. Resected patients lived longer before the onset of ascites, but not after. CONCLUSION: Once diagnosed, ascites in pancreatic cancer patients heralds imminent death. Limited survival should be considered when determining the aggressiveness of further intervention
The Real Need for Regenerative Medicine in the Future of Congenital Heart Disease Treatment
Bioabsorbable materials made from polymeric compounds have been used in many fields of regenerative medicine to promote tissue regeneration. These materials replace autologous tissue and, due to their growth potential, make excellent substitutes for cardiovascular applications in the treatment of congenital heart disease. However, there remains a sizable gap between their theoretical advantages and actual clinical application within pediatric cardiovascular surgery. This review will focus on four areas of regenerative medicine in which bioabsorbable materials have the potential to alleviate the burden where current treatment options have been unable to within the field of pediatric cardiovascular surgery. These four areas include tissue-engineered pulmonary valves, tissue-engineered patches, regenerative medicine options for treatment of pulmonary vein stenosis and tissue-engineered vascular grafts. We will discuss the research and development of biocompatible materials reported to date, the evaluation of materials in vitro, and the results of studies that have progressed to clinical trials
Prognostic significance of new onset ascites in patients with pancreatic cancer
Abstract Background The purpose of this study was to determine risk factors for development of malignant ascites and its prognostic significance in patients with pancreatic cancer. Methods A prospective database was queried to identify patients with pancreatic cancer who develop ascites. Stage at presentation, size, and location of primary tumor, treatment received and length of survival after onset of ascites were determined. Results A total of 15 patients were identified. Of which 4 patients (1 stage II, 3 stage III) underwent pancreaticoduodenectomy and manifested with ascites 2, 3, 24 and 47 months after surgery (tumor size 2.9 ± 1.32 cm). All but one of the remaining 11 patients (tumor size 4.4 ± 3.38 cm) presented with metastatic disease, and all developed malignant ascites 9 months after diagnosis, dying 2 months later. Resected patients lived longer before the onset of ascites, but not after. Conclusion Once diagnosed, ascites in pancreatic cancer patients heralds imminent death. Limited survival should be considered when determining the aggressiveness of further intervention.</p
Recommended from our members
Use of rotational angiography in congenital cardiac catheterisations to generate three-dimensional-printed models
Background: Three-dimensional printing is increasingly utilised for congenital heart defect procedural planning. CT or MR datasets are typically used for printing, but similar datasets can be obtained from three-dimensional rotational angiography. We sought to assess the feasibility and accuracy of printing three-dimensional models of CHD from rotational angiography datasets. Methods: Retrospective review of CHD catheterisations using rotational angiography was performed, and patient and procedural details were collected. Imaging data from rotational angiography were segmented, cleaned, and printed with polylactic acid on a Dremel® 3D Idea Builder (Dremel, Mount Prospect, IL, USA). Printing time and materials' costs were captured. CT scans of printed models were compared objectively to the original virtual models. Two independent, non-interventional paediatric cardiologists provided subjective ratings of the quality and accuracy of the printed models. Results: Rotational angiography data from 15 catheterisations on vascular structures were printed. Median print time was 3.83 hours, and material costs were $2.84. The CT scans of the printed models highly matched with the original digital models (root mean square for Hausdorff distance 0.013 ± 0.003 mesh units). Independent reviewers correctly described 80 and 87% of the models (p = 0.334) and reported high quality and accuracy (5 versus 5, p = NS; κ = 0.615). Conclusion: Imaging data from rotational angiography can be converted into accurate three-dimensional-printed models of CHD. The cost of printing the models was negligible, but the print time was prohibitive for real-time use. As the speed of three-dimensional printing technology increases, novel future applications may allow for printing patient-specific devices based on rotational angiography datasets. © 2021 The Author(s). Published by Cambridge University Press.6 month embargo; first published online 18 February 2021This item from the UA Faculty Publications collection is made available by the University of Arizona with support from the University of Arizona Libraries. If you have questions, please contact us at [email protected]
Gap Assessment in the Emergency Response Community
This report describes a gap analysis of the emergency response and management (EM) community, performed during the fall of 2009. Pacific Northwest National Laboratory (PNNL) undertook this effort to identify potential improvements to the functional domains in EM that could be provided by the application of current or future technology. To perform this domain-based gap analysis, PNNL personnel interviewed subject matter experts (SMEs) across the EM domain; to make certain that the analyses reflected a representative view of the community, the SMEs were from a variety of geographic areas and from various sized communities (urban, suburban, and rural). PNNL personnel also examined recent and relevant after-action reports and U.S. Government Accountability Office reports
Percutaneous Balloon-Expandable Stent Implantation to Treat Transverse Aortic Arch Obstruction: Medium- to Long-Term Outcomes of a Retrospective Multicenter Study
BACKGROUND: Transverse aortic arch obstruction is a challenging lesion for which stent implantation provides a potentially important alternate therapy. The objectives were to evaluate the technical, procedural, and medium-to-long-term clinical outcomes of percutaneous stent implantation of transverse aortic arch obstruction. METHODS: This is a retrospective, multicenter study of transverse aortic arch stent implantation. Univariable and multivariable analyses were performed. RESULTS: Index catheterization included 187 stent implants in 146 patients. The median age is 14.3 years (interquartile range, 9.3-19), weight is 53 kg (30-69), and follow-up is 53 months (12-120). The most common stent design was open cell (n=90, 48%). Stents overlapped 142 arch vessels (37 carotid arteries) in 118 (81%) cases. Technical and procedural success rates were 100% and 88%, respectively. Lower weight ( P=0.018), body surface area ( P=0.013), and minimum-to-descending aortic diameter ratio ( P10 mm Hg was associated with increased odds of reintervention at all time points when controlling for each final dilation diameter, weight, and minimum-to-descending aortic diameter ratio. CONCLUSIONS: Transverse aortic arch stent implantation has high rates of technical, procedural, and medium-to-long-term clinical success. Aortic gradient >10 mm Hg is associated with increased odds of reintervention at 1-year and most recent follow-ups. Open cell stent design was frequently used for its advantages in conformability, perfusion of arch vessels, low fracture rate, and the ability to perform effective angioplasty of side cells