    Using a NPWE model observer to assess suitable image quality for a digital mammography quality assurance programme

    Get PDF
    A method of objectively determining imaging performance for a mammography quality assurance programme for digital systems was developed. The method is based on the assessment of the visibility of a spherical microcalcification of 0.2 mm using a quasi-ideal observer model. It requires the assessment of the spatial resolution (modulation transfer function) and the noise power spectra of the systems. The contrast is measured using a 0.2-mm thick Al sheet and Polymethylmethacrylate (PMMA) blocks. The minimal image quality was defined as that giving a target contrast-to-noise ratio (CNR) of 5.4. Several evaluations of this objective method for evaluating image quality in mammography quality assurance programmes have been considered on computed radiography (CR) and digital radiography (DR) mammography systems. The measurement gives a threshold CNR necessary to reach the minimum standard image quality required with regards to the visibility of a 0.2-mm microcalcification. This method may replace the CDMAM image evaluation and simplify the threshold contrast visibility test used in mammography qualit

    Individual monitoring of internal exposure for nuclear medicine workers in Switzerland

    Get PDF
    Monitoring of internal exposure for nuclear medicine workers requires frequent measurements due to the short physical half-lives of most radionuclides used in this field. The aim of this study was to develop screening measurements performed at the workplace by local staff using standard laboratory instrumentation, to detect whether potential intake has occurred. Such measurements do not enable to determine the committed effective dose, but are adequate to verify that a given threshold is not exceeded. For radioiodine, i.e. 123I, 124I, 125I and 131I, a calibrated surface contamination monitor is placed in front of the thyroid to detect whether the activity threshold has been exceeded. For radionuclides with very short physical half-lives (≤6 h), such as 99mTc and those used in positron emission tomography imaging, i.e. 11C, 15O, 18F and 68Ga, screening procedures consist in performing daily measurements of the ambient dose rate in front of the abdomen. Other gamma emitters used for imaging, i.e. 67Ga, 111In and 201Tl, are measured with a scintillation detector located in front of the thorax. For pure beta emitters, i.e. 90Y and 169Er, as well as beta emitters with low-intensity gamma rays, i.e. 153Sm, 177Lu, 186Re and 188Re, the procedure consists in measuring hand contamination immediately after use. In Switzerland, screening procedures have been adopted by most nuclear medicine services since such measurements enable an acceptable monitoring while taking into account practical and economic consideration

    Neutron measurements around storage casks containing spent fuel and vitrified high-level radioactive waste at ZWILAG

    Get PDF
    Spectrometric and dosimetric measurements were made around a cask containing spent fuel and a cask containing high-level radioactive waste at the Swiss intermediate waste and spent fuel storage facility. A Bonner sphere spectrometer, an LB 6411 neutron monitor and an Automess Szintomat 6134A were used to characterise the n-γ fields at several locations around the two casks. The results of these measurements show that the neutron fluence spectra around the cask containing radioactive waste are harder and higher in intensity than those measured in the vicinity of the spent fuel cask. The ambient dose equivalents measured with the LB 6411 neutron monitor are in good agreement with those obtained using the Bonner spheres, except for locations with soft neutron spectra where the monitor overestimates the neutron ambient dose equivalent by almost 50

    Determining the activity of 241Pu by liquid scintillation counting

    Get PDF
    Liquid scintillation counting (LSC) is one of the most widely used methods for determining the activity of 241Pu. One of the main challenges of this counting method is the efficiency calibration of the system for the low beta energies of 241Pu (E max=20.8 keV). In this paper we compare the two most frequently used methods, the CIEMAT/NIST efficiency tracing (CNET) method and the experimental quench correction curve method. Both methods proved to be reliable, and agree within their uncertainties, for the expected quenching conditions of the source

    Calibration of surface contamination monitors for the detection of iodine incorporation in the thyroid gland

    Get PDF
    In Switzerland, individuals exposed to the risk of activity intake are required to perform regular monitoring. Monitoring consists in a screening measurement and is meant to be performed using commonly available laboratory instruments. More particularly, iodine intake is measured using a surface contamination monitor. The goal of the present paper is to report the calibration method developed for thyroid screening instruments. It consists of measuring the instrument response to a known activity located in the thyroid gland of a standard neck phantom. One issue of this procedure remains that the iodine radioisotopes have a short half-life. Therefore, the adequacy and limitations to simulate the short-lived radionuclides with so-called mock radionuclides of longer half-life were also evaluated. In light of the results, it has been decided to use only the appropriate iodine sources to perform the calibratio

    Speciation and Bioavailability Measurements of Environmental Plutonium Using Diffusion in Thin Films.

    Get PDF
    The biological uptake of plutonium (Pu) in aquatic ecosystems is of particular concern since it is an alpha-particle emitter with long half-life which can potentially contribute to the exposure of biota and humans. The diffusive gradients in thin films technique is introduced here for in-situ measurements of Pu bioavailability and speciation. A diffusion cell constructed for laboratory experiments with Pu and the newly developed protocol make it possible to simulate the environmental behavior of Pu in model solutions of various chemical compositions. Adjustment of the oxidation states to Pu(IV) and Pu(V) described in this protocol is essential in order to investigate the complex redox chemistry of plutonium in the environment. The calibration of this technique and the results obtained in the laboratory experiments enable to develop a specific DGT device for in-situ Pu measurements in freshwaters. Accelerator-based mass-spectrometry measurements of Pu accumulated by DGTs in a karst spring allowed determining the bioavailability of Pu in a mineral freshwater environment. Application of this protocol for Pu measurements using DGT devices has a large potential to improve our understanding of the speciation and the biological transfer of Pu in aquatic ecosystems

    Number of X-ray examinations performed on paediatric and geriatric patients compared with adult patients

    Get PDF
    The age of the patient is of prime importance when assessing the radiological risk to patients due to medical X-ray exposures and the total detriment to the population due to radiodiagnostics. In order to take into account the age-specific radiosensitivity, three age groups are considered: children, adults and the elderly. In this work, the relative number of examinations carried out on paediatric and geriatric patients is established, compared with adult patients, for radiodiagnostics as a whole, for dental and medical radiology, for 8 radiological modalities as well as for 40 types of X-ray examinations. The relative numbers of X-ray examinations are determined based on the corresponding age distributions of patients and that of the general population. Two broad groups of X-ray examinations may be defined. Group A comprises conventional radiography, fluoroscopy and computed tomography; for this group a paediatric patient undergoes half the number of examinations as that of an adult, and a geriatric patient undergoes 2.5 times more. Group B comprises angiography and interventional procedures; for this group a paediatric patient undergoes a one-fourth of the number of examinations carried out on an adult, and a geriatric patient undergoes five times mor

    Activity standardisation of 177Lu.

    Get PDF
    <sup>177</sup> Lu decays through low-energy β <sup>-</sup> - and γ-emissions in addition to conversion and Auger electrons. To support the use of this radiopharmaceutical in Switzerland, a <sup>177</sup> Lu solution was standardised using the β-γ coincidence technique, as well as the TDCR method. The solution had no <sup>177m</sup> Lu impurity. Primary coincidence measurements, with plastic scintillators for beta detection, were carried out using both analogue and digital electronics. TDCR measurements using only defocusing were also made. Monte Carlo calculations were used to compute the detection efficiency. The coincidence measurements with both analogue and digital electronics are compatible within one standard uncertainty, but they are lower than (and discrepant with) the TDCR measurements. An ampoule of this solution was submitted to the BIPM as a contribution to the Système International de Référence

    Fluoroscopy-guided procedures in cardiology: is patient exposure being reduced over time?

    Get PDF
    The number of fluoroscopy-guided procedures in cardiology is increasing over time and it is appropriate to wonder whether technological progress or change of techniques is influencing patient exposure. The aim of this study is to examine whether patient dose has been decreasing over the years. Patient dose data of more than 7700 procedures were collected from two cardiology centres. A steady increase in the patient dose over the years was observed in both the centres for the two cardiological procedures included in this study. Significant increase in dose was also observed after the installation of a flat-panel detector. The increasing use of radial access may lead to an increase in the patient exposure. The monitoring of dose data over time showed a considerable increase in the patient exposure over time. Actions have to be taken towards dose reduction in both the centre

    Calibration of an HPGe detector and self-attenuation correction for Pb-210: Verification by alpha spectrometry of Po-210 in environmental samples

    Get PDF
    In this work the calibration of an HPGe detector for Pb-210 measurement is realised by a liquid standard source and the determination of this radionuclide in solid environmental samples by gamma spectrometry takes into account a correction factor for self-attenuation of its 46.5 keV line. Experimental, theoretical and Monte Carlo investigations are undertaken to evaluate self-attenuation for cylindrical sample geometry. To validate this correction factor (at equilibrium with Po-210 Pb-210) alpha spectrometry procedure using microwave acid digestion under pressure is developed and proposed. The different self-attenuation correction methods are in coherence, and corrected Pb-210 activities are in good agreement with the results of Po-210. Finally, self-attenuation corrections are proposed for environmental solid samples whose density ranges between 0.8 and 1.4 g/cm(3) and whose mass attenuation coefficient is around 0.4 cm(2)/g. (C) 2007 Elsevier B.V. All rights reserved