34 research outputs found

    Chlamydophila pneumoniae infection in patients undergoing carotid artery stent.

    Get PDF
    Although several reports have correlated Chlamydophila pneumoniae (CP) infection with carotid endarterectomy and coronary stent, no data have been reported on the potential relationship between this pathogen and carotid artery stenting (CAS). Hence, we evaluated 47 subjects, 27 symptomatic and 20 asymptomatic, before CAS intervention and during the follow up, for the presence of CP DNA and anti-CP antibodies, including chlamydial HSP60 (Cp-HSP60). Before stent placement, CP DNA was detected exclusively in symptomatic patients, all of whom were also positive for CP IgG and IgA and 85.7% of them also had CP-HSP60 antibodies. At the follow-up, all CP DNA positive and 11 out of the 13 symptomatic patients with Cp-HSP60 antibodies became negatives. In contrast, no change was observed for CP- IgA antibodies. Despite the small number of patients, the present study advocates an important role of CP infection in symptomatic patients with carotid artery disease. Our findings also suggest that stent placement and/or therapy might have a role in favouring resolution of inflammation, though not affecting persistence of CP infection

    Carotid Intervention 3: The Evidence for Cerebral Protection

    No full text
    Carotid stenting is a safe alternative option to conventional carotid endarterectomy in the treatment of carotid artery stenosis in patients considered poor candidates for surgery or who choose not to have open surgery. During the stenting procedure, however, distal embolization may occur with neurological sequelae. To reduce the incidence of this, several cerebral-protection devices (CPDs) have been developed. Different types of CPDs are now commercially available: distal occlusion balloons, distal filters, and proximal protection devices with or without reversal of flow. But complications can occur with their use and are usually associated with an inability to cross the lesion, failure to capture the emboli, vasospasm, and vessel wall injury. Because protection devices are currently the focus of interest by manufacturers and physicians, several trials are going on worldwide to analyze the characteristics of each of them and to evaluate their efficacy in reducing the rate of distal embolization

    Techniques in cerebral protection

    No full text
    Carotid angioplasty and stenting is a valid alternative option to conventional carotid endarterectomy in the treatment of carotid artery stenosis. During the stenting process, however, distal embolization can occur with neurological consequences. To avoid this, cerebral protection devices have been introduced. Three principal types of protection system have been developed: distal balloon occlusion, distal filters and proximal protection with or without reversal of flow. As protection devices became the focus of interest by manufactures and physicians, several trials are going on worldwide to analyze the characteristics of each of them and to evaluate their efficacy to reduce the rate of distal embolization

    Endovascular treatment of hepatocellular carcinoma with drug eluting microparticles (DC-Beads): CT evaluation of response to the treatment

    No full text
    Background and Study Aims: Our aim was to assess the efficacy and tolerability of drug-eluting beads-transarterial chemoembolization (DEB-TACE) in the treatment of hepatocellular carcinoma (HCC), evaluating the response to the treatment after 1, 6, 12, and 24 months with multidetector computed tomography (MDCT) comparing European Association for the study of the Liver (EASL) and modified Response Evaluation Criteria in Solid Tumors (mRECIST) criteria. Materials and Methods: We enrolled 154 patients with uni- or multifocal HCC who underwent a DEB-TACE. A total of 278 HCC nodules were treated. CT follow-up was performed at 1, 6, 12, and 24 months after the procedure according to the EASL and RECIST criteria evaluating overall target and target nodule response. We also analyzed the shrinking of nodules in relation to response to treatment. Results: A total of 278 nodules of HCC underwent TACE by using DC-Beads: At 24, months complete response was similar for EASL and RECIST criteria (112 vs. 121 nodules) with optimal accordance between methods and readers with k = 0.9. Partial Response resulted significantly different among the two methods within the first month, otherwise was similar after 24-month follow-up. Similar results in both methods were found for nodules classified as Stable Disease (P > 0.05). Progressive Disease results were similar in both the groups according to both the classification criteria without any significant difference (P > 0.05). Conclusion: Our study confirmed that EASL and mRECIST criteria are both effective methods for patient follow-up, however with some technical differences

    Multidetector-Row Computed Tomography in the Evaluation of Transjugular Intrahepatic Portosystemic Shunt Performed with Expanded-Polytetrafluoroethylene-Covered Stent-Graft

    No full text
    We assessed, in a prospective study, the efficacy of multidetector spiral computed tomography (MDCT) in the evaluation of transjugular intrahepatic portosystemic shunt (TIPS) patency in patients treated with the Viatorr (Gore, Flagstaff, AZ) expanded-polytetrafluoroethylene (e-PTFE)-covered stent-graft. Eighty patients who underwent TIPS procedure using the Viatorr self-expanding e-PTFE stent-graft were evaluated at follow-up of 1, 3, 6, and 12 months with clinical and laboratory tests as well as ultrasound-color Doppler (USCD) imaging. In case of varices, upper gastrointestinal endoscopy was also performed. In addition, the shunt was evaluated using MDCT at 6 and 12 months. In all cases of abnormal findings and discrepancy between MDCT and USCD, invasive control venography was performed. MDCT images were acquired before and after injection of intravenous contrast media on the axial plane and after three-dimensional reconstruction using different algorithms. MDCT was successfully performed in all patients. No artefacts correlated to the Viatorr stent-graft were observed. A missing correlation between UCSD and MDCT was noticed in 20 of 80 (25%) patients. Invasive control venography confirmed shunt patency in 16 (80%) cases and shunt malfunction in 4 (20%) cases. According to these data, MDCT sensitivity was 95.2%; specificity was 96.6%; and positive (PPV) and negative predictive values (NPV) were 90.9 and 98.2%, respectively. USCD sensitivity was 90%; specificity was 75%; and PPV and NPV were 54.5 and 95.7%, respectively. A high correlation (K value = 0.85) between MDCT and invasive control venography was observed. On the basis of these results, MDCT shows superior sensitivity and specificity compared with USCD in those patients in whom TIPS was performed with the Viatorr stent-graft. MDCT can be considered a valid tool in the follow-up of these patients

    Management of refractory hepatic encephalopathy after insertion of TIPS: Long-term results of shunt reduction with hourglass-shaped balloon-expandable stent-graft

    No full text
    OBJECTIVE. The purpose of this study was to review the use of an hourglass-shaped expanded polytetrafluoroethylene (ePTFE) stent-graft to reduce transjugular intrahepatic portosystemic shunts in patients with hepatic encephalopathy refractory to conventional medical therapy. MATERIALS AND METHODS. From January 2000 through December 2008, 189 transjugular intrahepatic portosystemic shunt procedures were performed with self-expanding stent-grafts. After a mean period of 43.4 ± 57 weeks, hepatic encephalopathy developed in 12 patients and did not respond to conventional medical therapy with lactulose, nonabsorbable antibiotics, and a protein-restricted diet. In all cases, shunt reduction was performed with an hourglass-shaped balloon-expandable ePTFE stent-graft inserted into the original shunt. RESULTS. Technically successful shunt reduction with an immediate increase in portosystemic gradient was achieved in all patients. Symptoms of hepatic encephalopathy disappeared a mean of 22.3 hours (range, 18-26 hours) after the procedure. After a mean followup period of 73.9 ± 61.88 weeks, no recurrence of hepatic encephalopathy was found. One patient (8.3%) needed dilation of the hourglass-shaped stent-graft after 37 weeks because of recurrence of ascites. At the end of the study, five patients (41.6%) were alive in good clinical condition. Four patients (33.3%) died of cardiovascular failure 1, 2, 24, and 96 weeks after the corrective procedure. Eight months after the reduction procedure, one patient (8.3%) underwent orthotopic liver transplantation, which resulted in clinical improvement. Two patients (16.6%) were lost to follow-up 15.6 and 46.8 weeks after the procedure. CONCLUSION. Shunt reduction with an hourglass-shaped ePTFE balloon-expandable stent-graft seems effective in reducing shunt flow and rapidly improving the patient's clinical condition. With this technique, shunt diameter can be modified on the basis of the patient's clinical condition. © American Roentgen Ray Society

    Chlamydophila Pneumoniae

    No full text
    Although several reports have correlated Chlamydophila pneumoniae (CP) infection with carotid endarterectomy and coronary stent, no data have been reported on the potential relationship between this pathogen and carotid artery stenting (CAS). Hence, we evaluated 47 subjects, 27 symptomatic and 20 asymptomatic, before CAS intervention and during the follow up, for the presence of CP DNA and anti-CP antibodies, including chlamydial HSP60 (Cp-HSP60). Before stent placement, CP DNA was detected exclusively in symptomatic patients, all of whom were also positive for CP IgG and IgA and 85.7% of them also had CP-HSP60 antibodies. At the follow-up, all CP DNA positive and 11 out of the 13 symptomatic patients with Cp-HSP60 antibodies became negatives. In contrast, no change was observed for CP- IgA antibodies. Despite the small number of patients, the present study advocates an important role of CP infection in symptomatic patients with carotid artery disease. Our findings also suggest that stent placement and/or therapy might have a role in favouring resolution of inflammation, though not affecting persistence of CP infection
    corecore