143 research outputs found

    Investigation of In-Situ Stresses in Rocks via Acoustic Emission and the Kaiser Effect.

    Get PDF
    This paper is a proposal for designing the Kaiser In‐Situ Stress (KISS) System. The KISS System’s goal is to determine in‐situ stresses in rock formations and other subsurface rocks by means of compression‐induced Acoustic Emission (AE) and the Kaiser effect. The KISS System is a non‐destructive method of in‐situ stress determination and has received much attention in the past. To fully understand AE, the Kaiser Effect and how it relates to stress determination this paper will present the necessary theoretical background, past experimentation and results from the authors own experimentation to investigate the plausibility of AE and the Kaiser Effect for in‐situ stress determination. The final goal of the design is to investigate the uniaxial compression induced AE and the Kaiser Effect in rock to determine the fundamental process of the Kaiser Effect. Once confirmation of the Kaiser Effect from the uniaxial compression method is obtained, based on experimentation, more sophisticated experimentation with triaxial compression‐induced AE and the Kaiser Effect can be analyzed. Besides only proposing the KISS System as a theoretical design this paper also presents results from an initial design/prototype KISS System. In order to find out the plausibility of using AE and the Kaiser Effect for in‐situ stress determination, experimentation had to be conducted using fundamental processes. Theoretical work on AE and the Kaiser effect has been investigated extensively and the only way to determine scientific plausibility is by empirical observation and analysis. The process investigates uniaxial compression induced AE to determine the presence of the Kaiser effect. By actually performing the experiments that quantify physical phenomena comparisons can be made to see if uniaxial compression induced AE can determine in‐situ stresses and be developed further to determine true states of in‐situ stress

    Regional myocardial blood flow reserve impairment and metabolic changes suggesting myocardial ischemia in patients with idiopathic dilated cardiomyopathy

    Get PDF
    AbstractOBJECTIVESWe performed positron emission tomography (PET) to evaluate myocardial ischemia in patients with idiopathic dilated cardiomyopathy (IDC).BACKGROUNDPatients with IDC have anatomically normal coronary arteries, and it has been assumed that myocardial ischemia does not occur.METHODSWe studied 22 patients with IDC and 22 control subjects using PET with nitrogen-13 ammonia to measure myocardial blood flow (MBF) at rest and during dipyridamole-induced hyperemia. To investigate glucose metabolism, fluorine-18 deoxyglucose (18FDG) was used. For imaging of oxygen consumption, carbon-11 acetate clearance rate constants (kmono) were assessed at rest and during submaximal dobutamine infusion (20 μg/kg body weight per min).RESULTSGlobal MBF reserve (dipyridamole-induced) was impaired in patients with IDC versus control subjects (1.7 ± 0.21 vs. 2.7 ± 0.10, p < 0.05). In patients with IDC, MBF reserve correlated with left ventricular (LV) systolic wall stress (r = −0.61, p = 0.01). Furthermore, in 16 of 22 patients with IDC (derived by dipyridamole perfusion) mismatch (decreased flow/increased 18FDG uptake) was observed in 17 ± 8% of the myocardium. The extent of mismatch correlated with LV systolic wall stress (r = 0.64, p = 0.02). The MBF reserve was lower in the mismatch regions than in the normal regions (1.58 ± 0.13 vs. 1.90 ± 0.18, p < 0.05). During dobutamine infusion kmonowas higher in the mismatch regions than in the normal regions (0.104 ± 0.017 vs. 0.087 ± 0.016 min−1, p < 0.05). In the mismatch regions 18FDG uptake correlated negatively with rest kmono(r = −0.65, p < 0.05), suggesting a switch from aerobic to anaerobic metabolism.CONCLUSIONSPatients with IDC have a decreased MBF reserve. In addition, low MBF reserve was paralleled by high LV systolic wall stress. These global observations were associated with substantial myocardial mismatch areas showing the lowest MBF reserves. In geographically identical regions an abnormal oxygen consumption pattern was seen together with a switch from aerobic to anaerobic metabolism. These data support the notion that regional myocardial ischemia plays a role in IDC

    Myocardial perfusion reserve compared with peripheral perfusion reserve: A [13N]ammonia PET study

    Get PDF
    INTRODUCTION: [13N]ammonia PET allows quantification of myocardial perfusion. The similarity between peripheral flow and myocardial perfusion is unclear. We compared perfusion flow in the myocardium with the upper limb during rest and adenosine stress [13N]ammonia PET to establish whether peripheral perfusion reserve (PPR) correlates with MPR. METHODS: [13N]ammonia myocardial perfusion PET-scans of 58 patients were evaluated (27 men, 31 women, age 64 ± 13 years) and were divided in four subgroups: patients with coronary artery disease (CAD, n = 15), cardiac syndrome X (SX, n = 14), idiopathic dilating cardiomyopathy (DCM, n = 16), and normal controls (NC, n = 13). Peripheral limb perfusion was measured in the muscular tissue of the proximal upper limb and quantified through a 2-tissue-compartment model and the PPR was calculated (stress/rest ratio). MPR was also calculated by a 2-tissue-compartment model. The PPR results were compared with the MPR findings. RESULTS: Mean myocardial perfusion increased significantly in all groups as evidenced by the MPR (CAD 1.99 ± 0.47; SX 1.39 ± 0.31; DCM 1.72 ± 0.69; NC 2.91 ± 0.78). Mean peripheral perfusion also increased but not significantly and accompanied with great variations within and between groups (mean PPR: CAD 1.30 ± 0.79; SX 1.36 ± 0.71; DCM 1.60 ± 1.22; NC 1.27 ± 0.63). The mean difference between PPR and MPR for all subpopulations varied widely. No significant correlations in flow reserve were found between peripheral and myocardial microcirculatory beds in any of the groups (Total group: r = -0.07, SEE = 0.70, CAD: r = 0.14, SEE = 0.48, SX: r = 0.17, SEE = 0.30, DCM: r = -0.11, SEE = 0.71, NC: r = -0.19, SEE = 0.80). CONCLUSION: No correlations between myocardial and peripheral perfusion (reserve) were found in different patient populations in the same PET session. This suggests a functional difference between peripheral and myocardial flow in the response to intravenously administered adenosine stress

    Ischemic patterns assessed by positron emission tomography predict adverse outcome in patients with idiopathic dilated cardiomyopathy

    Get PDF
    Although patients with idiopathic dilated cardiomyopathy (DCM) have no coronary artery disease, regional impairment of myocardial perfusion combined with preserved metabolism has been found using positron emission tomography (PET). Our aim was to assess the prognostic relevance of PET-mismatch between stress myocardial perfusion and glucose uptake on clinical outcome in DCM. In 24 patients with DCM who underwent both myocardial perfusion and metabolism PET scanning, "mismatch" was assessed and the association with clinical outcome (hospitalization, mortality, and heart transplantation) was investigated. Mismatch was found in 16 patients (66.7%). Univariate analysis showed that the presence of mismatch was associated with adverse outcome (P = 0.03). After adjustment for sex and age, the association remained significant with an adjusted relative risk of 10.4 (95% CI 1.1-103; P = 0.04) for death, heart transplant, or hospitalization. Univariate analysis also showed that a higher extent of mismatch was significantly associated with adverse outcome (P = 0.02). After adjusting for sex and age, the association remained significant with an adjusted relative risk of 6.5 [95% CI 1.2-36; P = 0.03] for death, heart transplantation, or hospitalization. PET stress perfusion-metabolism mismatch, indicative for ischemia, is frequently found in DCM patients and related to a poorer outcome

    The NTI-tss device for the therapy of bruxism, temporomandibular disorders, and headache – Where do we stand? A qualitative systematic review of the literature

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The NTI-tss device is an anterior bite stop, which, according to the manufacturer, is indicated for the prevention and treatment of bruxism, temporomandibular disorders (TMDs), tension-type headaches, and migraine. The aim of this systematic review was to appraise the currently available evidence regarding the efficacy and safety of the NTI-tss splint.</p> <p>Methods</p> <p>We performed a systematic search in nine electronic databases and in NTI-tss-associated websites (last update: December 31, 2007). The reference lists of all relevant articles were perused. Five levels of scientific quality were distinguished. Reporting quality of articles about randomized controlled trials (RCTs) was evaluated using the Jadad score. To identify adverse events, we searched in the identified publications and in the MAUDE database.</p> <p>Results</p> <p>Nine of 68 relevant publications reported about the results of five different RCTs. Two RCTs concentrated on electromyographic (EMG) investigations in patients with TMDs and concomitant bruxism (Baad-Hansen et al 2007, Jadad score: 4) or with bruxism alone (Kavaklı 2006, Jadad score: 2); in both studies, compared to an occlusal stabilization splint the NTI-tss device showed significant reduction of EMG activity. Two RCTs focused exclusively on TMD patients; in one trial (Magnusson et al 2004, Jadad score: 3), a stabilization appliance led to greater improvement than an NTI-tss device, while in the other study (Jokstad et al 2005, Jadad score: 5) no difference was found. In one RCT (Shankland 2002, Jadad score: 1), patients with tension-type headache or migraine responded more favorably to the NTI-tss splint than to a bleaching tray. NTI-tss-induced complications related predominantly to single teeth or to the occlusion.</p> <p>Conclusion</p> <p>Evidence from RCTs suggests that the NTI-tss device may be successfully used for the management of bruxism and TMDs. However, to avoid potential unwanted effects, it should be chosen only if certain a patient will be compliant with follow-up appointments. The NTI-tss bite splint may be justified when a reduction of jaw closer muscle activity (e.g., jaw clenching or tooth grinding) is desired, or as an emergency device in patients with acute temporomandibular pain and, possibly, restricted jaw opening.</p

    �ber den Nachweis von �thylalkohol und Methylalkohol

    No full text
    corecore