Prefabricated ferrocement sandwich elements in fire conditions
Summary: In this paper the experimental results of two-dimensional non-stationary
temperature fields of prefabricated ferrocement sandwich panels in fire condition, were
presented. In order to determine resistance to fire, the temperature fields of two walls
dimensions of 3000 mm × 3000 mm and a thickness of 190 mm made from precast
ferrocement sandwich panels, were analyzed. The first panel has been insulated with
styro-concrete, and the second with styro-concrete and expanded polystyrene. The
panels were exposed to conditions of real fire corresponding to the standard fire curve
defined by the standard SRPS EN ISO 834-1. The tests have shown that, due to the
detonations that occur when the panels are exposed to fire, these panels have
unpredictable behavior