72 research outputs found
The feasibility of underwater computerised strain gauge plethysmography and the effects of hydrostatic pressure on the leg venous haemodynamics
Background: Strain gauge plethysmography (SGP) is employed to evaluate venous drainage of the lower leg.
Methods: In this study, SGP was used to evaluate the effects of the hydrostatic pressure (HP) of water on venous
volume (VV), expelled volume, and ejection fraction (EF) in 22 healthy legs before and during immersion in water.
Results: HP reduced VV by 100% and even more during underwater (UW) exercise, making calculation of the UW
EF possible.
Discussion: UW SGP is feasible and indicates that HP improves venous haemodynamics. This study suggests that
including UW leg exercise in the rehabilitation protocols of patients with chronic venous disease may be useful.
Keywords: Strain gauge plethysmography, Underwater compression, Underwater ejection fraction, Underwater
venous volume.
2020 The Aut
Utilizing numerical simulations to prevent stent graft kinking during thoracic endovascular aortic repair
Numerical simulations of thoracic endovascular aortic repair (TEVAR) may be implemented in the preoperative workflow if credible and reliable. We present the application of a TEVAR simulation methodology to an 82-year-old woman with a penetrating atherosclerotic ulcer in the left hemiarch, that underwent a left common carotid artery to left subclavian artery bypass and consequent TEVAR in zone 2. During the intervention, kinking of the distal thoracic stent graft occurred and the simulation was able to reproduce this event. This report highlights the potential and reliability of TEVAR simulations to predict perioperative adverse events and short-term postoperative technical results. (J Vasc Surg Cases Innov Tech 2023;9:101269.
Acute Lower Limb Ischaemia as a Presenting Sign of Atrial Myxoma: Case Report and Scoping Review of the Literature
Objective: Cardiac myxomas (CMs) are the most common primary cardiac tumour in adults. They are a rare cause of peripheral embolisation and may present as acute lower limb ischaemia (ALI). A scoping review was undertaken and a case of ALI due to CM embolisation is presented in this paper. Methods: MEDLINE, Scopus, and Embase were systematically searched for studies reporting data on ALI as a presentation of CM embolisation. The Preferred Reporting Items for Systematic Reviews and Meta-Analyses Extension for Scoping Reviews (PRISMA-ScR) was followed. Results: A healthy 26 year old female presented to the emergency department with bilateral ALI. Urgent bilateral aorto-iliac embolectomy and distal embolectomy of the left femoropopliteal axis were performed. The retrieved embolic material exhibited a yellowish appearance and jelly like consistency, and histological analysis provided a diagnosis of a myxomatous embolus. Transoesophageal echocardiography confirmed the left atrial origin of a myxomatous tumour, but the residual mass was considered too small for further excision. At a two year clinical follow up, the patient was alive and well without recurrence. Between 1989 and 2023, 59 patients with ALI due to CM embolisation were identified in the literature. An in hospital mortality rate of 12.1% (n = 7) was reported, while the in hospital complication and re-intervention rates were 34.5% (n = 20) and 27.6% (n = 16), respectively. No post-discharge deaths, complications, or re-interventions were reported; fasciotomies were the most reported (n = 10). Post-discharge follow up was reported in 22 (37.3%) patients. Mean follow up was 18.0 ± 18.8 months (range 1â120), and 86.4% of patients (n = 19) were alive and well at last follow up. Conclusion: This review and the associated case report underline that CM embolisation should be considered in healthy young patients presenting with cryptogenic ALI. Early transoesophageal echocardiography and histological analysis of the retrieved embolus are recommended to minimise misdiagnosis in these populations
Validation and Verification of High-Fidelity Simulations of Thoracic Stent-Graft Implantation
Thoracic Endovascular Aortic Repair (TEVAR) is the preferred treatment option for thoracic aortic pathologies and consists of inserting a self-expandable stent-graft into the pathological region to restore the lumen. Computational models play a significant role in procedural planning and must be reliable. For this reason, in this work, high-fidelity Finite Element (FE) simulations are developed to model thoracic stent-grafts. Experimental crimp/release tests are performed to calibrate stent-grafts material parameters. Stent pre-stress is included in the stent-graft model. A new methodology for replicating device insertion and deployment with explicit FE simulations is proposed. To validate this simulation, the stent-graft is experimentally released into a 3D rigid aortic phantom with physiological anatomy and inspected in a computed tomography (CT) scan at different time points during deployment with an ad-hoc set-up. A verification analysis of the adopted modeling features compared to the literature is performed. With the proposed methodology the error with respect to the CT is on average 0.92 +/- 0.64%, while it is higher when literature models are adopted (on average 4.77 +/- 1.83%). The presented FE tool is versatile and customizable for different commercial devices and applicable to patient-specific analyses
Comparison of Two Generations of Thoracic Aortic Stent Grafts and Their Impact on Aortic Stiffness in an Ex Vivo Porcine Model
Objective: Little is known about the cardiovascular changes after TEVAR and regarding the impact on aortic stiffness for different stent graft generations specifically, following changes in device design. The present study evaluated the stent graft induced aortic stiffening of two generations of the Valiant thoracic aortic stent graft. Methods: This was an ex vivo porcine investigation using an experimental mock circulatory loop. Thoracic aortas of young healthy pigs were harvested and connected to the mock circulatory loop. At a 60 bpm heart rate and stable mean arterial pressure, baseline aortic characteristics were obtained. Pulse wave velocity (PWV) was calculated before and after stent graft deployment. Paired and independent sample t tests or their non-parametric alternatives were performed to test for differences where appropriate. Results: Twenty porcine thoracic aortas were divided into two equal subgroups, in which a Valiant Captivia or a Valiant Navion stent graft was deployed. Both stent grafts were similar in diameter and length. Baseline aortic characteristics did not differ between the subgroups. Mean arterial pressure values did not change after either stent graft, while pulse pressures increased statistically significantly after Captivia (mean 44 ± 10 mmHg to 51 ± 13 mmHg, p = .002) but not after Navion. Mean baseline PWV increased after both Captivia (4.4 ± 0.6 m/s to 4.8 ± 0.7 m/s, p = .007) and Navion (4.6 ± 0.7 m/s to 4.9 ± 0.7 m/s, p = .002). There was no statistically significant difference in the mean percentage increase in PWV for either subgroup (8 ± 4% vs. 6 ± 4%, p = .25). Conclusion: These experimental findings showed no statistically significant difference in the percentage increase of aortic PWV after either stent graft generation and confirm that TEVAR increases aortic PWV. As a surrogate for aortic stiffness, this calls for further improvements in future thoracic aortic stent graft designs regarding device compliance
Utilizing numerical simulations to prevent stent graft kinking during thoracic endovascular aortic repair
Numerical simulations of thoracic endovascular aortic repair (TEVAR) may be implemented in the preoperative workflow if credible and reliable. We present the application of a TEVAR simulation methodology to an 82-year-old woman with a penetrating atherosclerotic ulcer in the left hemiarch, that underwent a left common carotid artery to left subclavian artery bypass and consequent TEVAR in zone 2. During the intervention, kinking of the distal thoracic stent graft occurred and the simulation was able to reproduce this event. This report highlights the potential and reliability of TEVAR simulations to predict perioperative adverse events and short-term postoperative technical results
Patientsâ Radiation Exposure During Endovascular Abdominal Aortic Aneurysm Repair
Background: To investigate associations between patient characteristics, intraprocedural complexity factors, and radiation exposure to patients during endovascular abdominal aortic aneurysm repair (EVAR). Methods: Elective standard EVAR procedures between January 2015 and December 2020 were retrospectively analyzed. Patient characteristics and intraprocedural data (i.e., type of device, endograft configuration, additional procedures, and contralateral gate cannulation time [CGCT]) were collected. Dose area product (DAP) and fluoroscopy time were considered as measurements of radiation exposure. Furthermore, effective dose (ED) and doses to internal organs were calculated using PCXMC 2.0 software. Descriptive statistics, univariable, and multivariable linear regression were applied to investigate predictors of increased radiation exposure. Results: The 99 patients were mostly male (90.9%) with a mean age of 74 ± 7 years. EVAR indications were most frequently abdominal aortic aneurysm (93.9%), penetrating aortic ulceration (2.0%), focal dissection (2.0%), or subacute rupture of infrarenal abdominal aortic aneurysm (2.0%). Median fluoroscopy time was 19.6 minutes (interquartile range [IQR], 14.1â29.4) and median DAP was 86,311 mGy cm2 (IQR, 60,160â130,385). Median ED was 23.2 mSv (IQR, 17.0â34.8) for 93 patients (93.9%). DAP and ED were positively correlated with body mass index (BMI) and CGCT. Kidneys, small intestine, active bone marrow, colon, and stomach were the organs that received the highest equivalent doses during EVAR. Higher DAP and ED values were observed using the Excluder endograft, other bi- and tri-modular endografts, and EVAR with â„2 additional procedures. Multivariable linear regression analysis revealed that BMI, â„2 additional procedures during EVAR, and CGCT were independent positive predictors of DAP and ED levels after accounting for endograft type. Conclusions: Patient-related and procedure-related factors such as BMI, â„2 additional procedures during EVAR, and CGCT resulted predictors of radiation exposure for patients undergoing EVAR, as quantified by higher DAP and ED levels. The main intraprocedural factor that increased radiation exposure was CGCT. These data can be of importance for better managing radiation exposure during EVAR
Type III aortic arch angulation increases aortic stiffness: Analysis from an ex vivo porcine model
Objective: The relationship among increased aortic arch angulation, aortic flow dynamics, and vessel wall stiffness remains unclear. This experimental ex vivo study investigated how increased aortic arch angulation affects aortic stiffness and stent-graft induced aortic stiffening, assessed by pulse wave velocity (PWV). Methods: Porcine thoracic aortas were connected to a circulatory mock loop in a Type I and Type III aortic arch configuration. Baseline characteristics and blood pressures were measured. Proximal and distal flow curves were acquired to calculate PWV in both arch configurations. After that, a thoracic stent-graft (VAMF2626C100TU) was deployed in aortas with adequate proximal landing zone diameters to reach 10% t0 20% oversizing. Acquisitions were repeated for both arch configurations after stent-graft deployment. Results: Twenty-four aortas were harvested, surgically prepared, and mounted. Cardiac output was kept constant for both arch configurations (Type I: 4.74 ± 0.40 and Type III: 4.72 ± 0.38 L/minute; P = .703). Compared with a Type I arch, aortic PWV increased significantly in the Type III arch (3.53 ± 0.40 vs 3.83 ± 0.40 m/second; P < .001), as well as blood pressures. A stent-graft was deployed in 15 aortas. After deployment, Type I arch PWV increased (3.55 ± 0.39 vs 3.81 ± 0.44 m/second; P < .001) and Type III arch PWV increased although not significantly (3.86 ± 0.42 vs 4.03 ± 0.46 m/second; P = .094). Type III arch PWV resulted the highest and significantly higher compared with the Type I arch after stent-graft deployment (3.81 ± 0.44 vs 4.03 ± 0.46 m/second; P = .023). Conclusions: Increased aortic arch angulationâas in a Type III archâis associated with higher aortic PWV and blood pressures and this may negatively influence cardiovascular health
International Multi-Institutional Experience with Presentation and Management of Aortic Arch Laterality in Aberrant Subclavian Artery and Kommerell's Diverticulum
Background: Aberrant subclavian artery (ASA) with or without Kommerell's diverticulum (KD) is a rare anatomic aortic arch anomaly that can cause dysphagia and/or life-threatening rupture. The objective of this study is to compare outcomes of ASA/KD repair in patients with a left versus right aortic arch.
Methods: Using the Vascular Low Frequency Disease Consortium methodology, a retrospective review was performed of patients â„18 years old with surgical treatment of ASA/KD from 2000 to 2020 at 20 institutions.
Results: 288 patients with ASA with or without KD were identified; 222 left-sided aortic arch (LAA), and 66 right-sided aortic arch (RAA). Mean age at repair was younger in LAA 54 vs. 58 years (P = 0.06). Patients in RAA were more likely to undergo repair due to symptoms (72.7% vs. 55.9%, P = 0.01), and more likely to present with dysphagia (57.6% vs. 39.1%, P < 0.01). The hybrid open/endovascular approach was the most common repair type in both groups. Rates of intraoperative complications, death within 30 days, return to the operating room, symptom relief and endoleaks were not significantly different. For patients with symptom status follow-up data, in LAA, 61.7% had complete relief, 34.0% had partial relief and 4.3% had no change. In RAA, 60.7% had complete relief, 34.4% had partial relief and 4.9% had no change.
Conclusions: In patients with ASA/KD, RAA patients were less common than LAA, presented more frequently with dysphagia, had symptoms as an indication for intervention, and underwent treatment at a younger age. Open, endovascular and hybrid repair approaches appear equally effective, regardless of arch laterality
Diversity and ethics in trauma and acute care surgery teams: results from an international survey
Background Investigating the context of trauma and acute care surgery, the article aims at understanding the factors that can enhance some ethical aspects, namely the importance of patient consent, the perceptiveness of the ethical role of the trauma leader, and the perceived importance of ethics as an educational subject. Methods The article employs an international questionnaire promoted by the World Society of Emergency Surgery. Results Through the analysis of 402 fully filled questionnaires by surgeons from 72 different countries, the three main ethical topics are investigated through the lens of gender, membership of an academic or non-academic institution, an official trauma team, and a diverse group. In general terms, results highlight greater attention paid by surgeons belonging to academic institutions, official trauma teams, and diverse groups. Conclusions Our results underline that some organizational factors (e.g., the fact that the team belongs to a university context or is more diverse) might lead to the development of a higher sensibility on ethical matters. Embracing cultural diversity forces trauma teams to deal with different mindsets. Organizations should, therefore, consider those elements in defining their organizational procedures. Level of evidence Trauma and acute care teams work under tremendous pressure and complex circumstances, with their members needing to make ethical decisions quickly. The international survey allowed to shed light on how team assembly decisions might represent an opportunity to coordinate team member actions and increase performance
- âŠ