39 research outputs found

    Reporting and Methods in Clinical Prediction Research: A Systematic Review

    Get PDF
    Walter Bouwmeester and colleagues investigated the reporting and methods of prediction studies in 2008, in six high-impact general medical journals, and found that the majority of prediction studies do not follow current methodological recommendations

    A genetic programming approach to development of clinical prediction models: A case study in symptomatic cardiovascular disease

    Get PDF
    BACKGROUND:Genetic programming (GP) is an evolutionary computing methodology capable of identifying complex, non-linear patterns in large data sets. Despite the potential advantages of GP over more typical, frequentist statistical approach methods, its applications to survival analyses are rare, at best. The aim of this study was to determine the utility of GP for the automatic development of clinical prediction models. METHODS:We compared GP against the commonly used Cox regression technique in terms of the development and performance of a cardiovascular risk score using data from the SMART study, a prospective cohort study of patients with symptomatic cardiovascular disease. The composite endpoint was cardiovascular death, non-fatal stroke, and myocardial infarction. A total of 3,873 patients aged 19-82 years were enrolled in the study 1996-2006. The cohort was split 70:30 into derivation and validation sets. The derivation set was used for development of both GP and Cox regression models. These models were then used to predict the discrete hazards at t = 1, 3, and 5 years. The predictive ability of both models was evaluated in terms of their risk discrimination and calibration using the validation set. RESULTS:The discrimination of both models was comparable. At time points t = 1, 3, and 5 years the C-index was 0.59, 0.69, 0.64 and 0.66, 0.70, 0.70 for the GP and Cox regression models respectively. At the same time points, the calibration of both models, which was assessed using calibration plots and the generalization of the Hosmer-Lemeshow test statistic, was also comparable, but with the Cox model being better calibrated to the validation data. CONCLUSION:Using empirical data, we demonstrated that a prediction model developed automatically by GP has predictive ability comparable to that of manually tuned Cox regression. The GP model was more complex, but it was developed in a fully automated way and comprised fewer covariates. Furthermore, it did not require the expertise normally needed for its derivation, thereby alleviating the knowledge elicitation bottleneck. Overall, GP demonstrated considerable potential as a method for the automated development of clinical prediction models for diagnostic and prognostic purposes

    Preparation and Application of Electrodes in Capacitive Deionization (CDI): a State-of-Art Review

    Get PDF
    As a promising desalination technology, capacitive deionization (CDI) have shown practicality and cost-effectiveness in brackish water treatment. Developing more efficient electrode materials is the key to improving salt removal performance. This work reviewed current progress on electrode fabrication in application of CDI. Fundamental principal (e.g. EDL theory and adsorption isotherms) and process factors (e.g. pore distribution, potential, salt type and concentration) of CDI performance were presented first. It was then followed by in-depth discussion and comparison on properties and fabrication technique of different electrodes, including carbon aerogel, activated carbon, carbon nanotubes, graphene and ordered mesoporous carbon. Finally, polyaniline as conductive polymer and its potential application as CDI electrode-enhancing materials were also discussed

    Capacitive Deionization -- defining a class of desalination technologies

    No full text
    Over the past decade, capacitive deionization (CDI) has realized a surge inattention in the field of water desalination and can now be considered as animportant technology class, along with reverse osmosis and electrodialysis.While many of the recently developed technologies no longer use a mechanismthat follows the strict definition of the term "capacitive", these methodsnevertheless share many common elements that encourage treating them withsimilar metrics and analyses. Specifically, they all involve electricallydriven removal of ions from a feed stream, storage in an electrode (i.e., ionelectrosorption) and release, in charge/discharge cycles. Grouping all thesemethods in the technology class of CDI makes it possible to treat evolving newtechnologies in standardized terms and compare them to other technologies inthe same class

    Markers for the non-invasive diagnosis of mesothelioma: a systematic review

    No full text
    BACKGROUND: Numerous markers have been evaluated to facilitate the non-invasive diagnostic work-up of mesothelioma. The purpose of this study was to conduct a structured review of the diagnostic performance of non-invasive marker tests for the detection of mesothelioma in patients with suspected mesothelioma. METHODS: Studies on the diagnostic accuracy of serum and cytological markers published till 31 December 2009, available in either PUBMED or Embase, to detect or exclude the presence of mesothelioma were extracted. Study quality was assessed with use of the Quadas criteria. RESULTS: In total, 82 articles were included in this systemic review. Overall, quality of the incorporated studies to address our objective was poor. The most frequently studied immunohistochemical markers for cytological analysis were EMA, Ber-Ep4, CEA, and calretinin. The most frequently investigated serum marker was soluble mesothelin-related protein (SMRP). The markers CEA, Ber-EP4, and calretinin were most valuable in discriminating mesothelioma from other malignant diseases. Markers EMA and SMRP were most valuable in discriminating mesothelioma from non-malignant diseases. No marker performed well in discriminating between mesothelioma and all other diseases. CONCLUSION: Currently, there is only limited evidence to properly assess the value of non-invasive marker tests in the diagnosis of mesothelioma. Studies were of limited value to address our objective and results showed considerable unexplained study heterogeneity
    corecore