539 research outputs found

    Cohort Profile: The Health Survey for England

    Get PDF
    To monitor the health of the public in England, UK, the Central Health Monitoring Unit within the UK Department of Health commissioned an annual health examination survey, which became known as the Health Survey for England (HSE). The first survey was completed in 1991. The HSE covers all of England and is a nationally representative sample of those residing at private residential addresses. Each survey year consists of a new sample of private residential addresses and people. The HSE collects detailed information on mental and physical health, health-related behaviour, and objective physical and biological measures in relation to demographic and socio-economic characteristics of people aged 16 years and over at private residential addresses. There are two parts to the HSE; an interviewer visit, to conduct an interview and measure height and weight, then a nurse visit, to carry out further measurements and take biological samples. Since 1994, survey participants aged 16 years and over have been asked for consent to follow-up through linkage to mortality and cancer registration data, and from 2003, to the Hospital Episode Statistics database, thus converting annual cross-sectional survey data into a longitudinal study. Annual survey data (1994–2009) are available through the UK Data Archive

    Indoor PM2.5 exposure in London's domestic stock: Modelling current and future exposures following energy efficient refurbishment

    Get PDF
    Simulations using CONTAM (a validated multi-zone indoor air quality (IAQ) model) are employed to predict indoor exposure to PM2.5 in London dwellings in both the present day housing stock and the same stock following energy efficient refurbishments to meet greenhouse gas emissions reduction targets for 2050. We modelled interventions that would contribute to the achievement of these targets by reducing the permeability of the dwellings to 3 m3 m−2 h−1 at 50 Pa, combined with the introduction of mechanical ventilation and heat recovery (MVHR) systems. It is assumed that the current mean outdoor PM2.5 concentration of 13 μg m−3 decreased to 9 μg m−3 by 2050 due to emission control policies. Our primary finding was that installation of (assumed perfectly functioning) MVHR systems with permeability reduction are associated with appreciable reductions in PM2.5 exposure in both smoking and non-smoking dwellings. Modelling of the future scenario for non-smoking dwellings show a reduction in annual average indoor exposure to PM2.5 of 18.8 μg m−3 (from 28.4 to 9.6 μg m−3) for a typical household member. Also of interest is that a larger reduction of 42.6 μg m−3 (from 60.5 to 17.9 μg m−3) was shown for members exposed primarily to cooking-related particle emissions in the kitchen (cooks). Reductions in envelope permeability without mechanical ventilation produced increases in indoor PM2.5 concentrations; 5.4 μg m−3 for typical household members and 9.8 μg m−3 for cooks. These estimates of changes in PM2.5 exposure are sensitive to assumptions about occupant behaviour, ventilation system usage and the distributions of input variables (±72% for non-smoking and ±107% in smoking residences). However, if realised, they would result in significant health benefits

    Indoor pm2.5 exposure in London's domestic stock: Modeling current and future exposures following energy efficient refurbishment

    Get PDF
    Simulations using CONTAM (a validated multi-zone indoor air quality (IAQ) model) are employed to predict indoor exposure to PM2.5 in London dwellings in both the present day housing stock and the same stock following energy efficient refurbishments to meet greenhouse gas emissions reduction targets for 2050. We modelled interventions that would contribute to the achievement of these targets by reducing the permeability of the dwellings to 3m3m-2hr-1 at 50 Pa, combined with the introduction of mechanical ventilation and heat recovery (MVHR) systems. It is assumed that the current mean outdoor PM2.5 concentration of 13?g.m-3 decreased to 9?g.m-3 by 2050 due to emission control policies. Our primary finding was that installation of (assumed perfectly functioning) MVHR systems with permeability reduction are associated with appreciable reductions in PM2.5 exposure in both smoking and non-smoking dwellings. Modelling of the future scenario for non-smoking dwellings show a reduction in annual average indoor exposure to PM2.5 of 18.8?g.m-3 (from 28.4 to 9.6?g.m-3) for a typical household member. Also of interest is that a larger reduction of 42.6?g.m-3 (from 60.5 to 17.9?g.m-3) was shown for members exposed primarily to cooking-related particle emissions in the kitchen (cooks). Reductions in envelope permeability without mechanical ventilation produced increases in indoor PM2.5 concentrations; 5.4?g.m-3 for typical household members and 9.8?g.m-3 for cooks. These estimates of changes in PM2.5 exposure are sensitive to assumptions about occupant behaviour, ventilation system usage and the distributions of input variables (±72% for non-smoking and ±107% in smoking residences). However, if realised, they would result in significant health benefits

    The modifying effect of the building envelope on population exposure to PM2.5 from outdoor sources.

    Get PDF
    UNLABELLED: A number of studies have estimated population exposure to PM2.5 by examining modeled or measured outdoor PM2.5 levels. However, few have taken into account the mediating effects of building characteristics on the ingress of PM2.5 from outdoor sources and its impact on population exposure in the indoor domestic environment. This study describes how building simulation can be used to determine the indoor concentration of outdoor-sourced pollution for different housing typologies and how the results can be mapped using building stock models and Geographical Information Systems software to demonstrate the modifying effect of dwellings on occupant exposure to PM2.5 across London. Building archetypes broadly representative of those in the Greater London Authority were simulated for pollution infiltration using EnergyPlus. In addition, the influence of occupant behavior on indoor levels of PM2.5 from outdoor sources was examined using a temperature-dependent window-opening scenario. Results demonstrate a range of I/O ratios of PM2.5 , with detached and semi-detached dwellings most vulnerable to high levels of infiltration. When the results are mapped, central London shows lower I/O ratios of PM2.5 compared with outer London, an apparent inversion of exposure most likely caused by the prevalence of flats rather than detached or semi-detached properties. PRACTICAL IMPLICATIONS: Population exposure to air pollution is typically evaluated using the outdoor concentration of pollutants and does not account for the fact that people in London spend over 80% of their time indoors. In this article, building simulation is used to model the infiltration of outdoor PM2.5 into the domestic indoor environment for dwellings in a London building stock model, and the results mapped. The results show the variation in relative vulnerability of dwellings to pollution infiltration, as well as an estimated absolute indoor concentration across the Greater London Authority (GLA) scaled by local outdoor levels. The practical application of this work is a better understanding of the modifying effect of the building geometry and envelope design on pollution exposure, and how the London building stock may alter exposure. The results will be used to inform population exposure to PM2.5 in future environmental epidemiological studies

    Childcare, choice and social class: Caring for young children in the UK

    Get PDF
    This paper draws on the results of two qualitative research projects examining parental engagements with the childcare market in the UK. Both projects are located in the same two London localities. One project focuses on professional middle class parents, and the other on working class families, and we discuss the key importance of social class in shaping parents' differential engagement with the childcare market, and their understandings of the role childcare plays in their children's lives. We identify and discuss the different "circuits" of care (Ball et al 1995) available to and used by families living physically close to each other, but in social class terms living in different worlds. We also consider parents' relationships with carers, and their social networks. We conclude that in order to fully understand childcare policies and practices and families' experiences of care, an analysis which encompasses social class and the workings of the childcare market is needed

    Low prevalence of Epstein–Barr virus in incident gastric adenocarcinomas from the United Kingdom

    Get PDF
    Epstein–Barr virus has been associated with a proportion of typical gastric adenocarcinomas. Here we report that the prevalence of Epstein–Barr virus in gastric adenocarcinomas from the United Kingdom is one of the lowest in the World. Gastric adenocarcinoma is another tumour whose association with Epstein–Barr virus varies with the population studied

    Differential (2+1) Jet Event Rates and Determination of alpha_s in Deep Inelastic Scattering at HERA

    Full text link
    Events with a (2+1) jet topology in deep-inelastic scattering at HERA are studied in the kinematic range 200 < Q^2< 10,000 GeV^2. The rate of (2+1) jet events has been determined with the modified JADE jet algorithm as a function of the jet resolution parameter and is compared with the predictions of Monte Carlo models. In addition, the event rate is corrected for both hadronization and detector effects and is compared with next-to-leading order QCD calculations. A value of the strong coupling constant of alpha_s(M_Z^2)= 0.118+- 0.002 (stat.)^(+0.007)_(-0.008) (syst.)^(+0.007)_(-0.006) (theory) is extracted. The systematic error includes uncertainties in the calorimeter energy calibration, in the description of the data by current Monte Carlo models, and in the knowledge of the parton densities. The theoretical error is dominated by the renormalization scale ambiguity.Comment: 25 pages, 6 figures, 3 tables, submitted to Eur. Phys.
    corecore