38 research outputs found

    Quantum Communication

    Get PDF
    Quantum communication, and indeed quantum information in general, has changed the way we think about quantum physics. In 1984 and 1991, the first protocol for quantum cryptography and the first application of quantum non-locality, respectively, attracted a diverse field of researchers in theoretical and experimental physics, mathematics and computer science. Since then we have seen a fundamental shift in how we understand information when it is encoded in quantum systems. We review the current state of research and future directions in this new field of science with special emphasis on quantum key distribution and quantum networks.Comment: Submitted version, 8 pg (2 cols) 5 fig

    Doses to internal organs for various breast radiation techniques - implications on the risk of secondary cancers and cardiomyopathy

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Breast cancers are more frequently diagnosed at an early stage and currently have improved long term outcomes. Late normal tissue complications induced by adjuvant radiotherapy like secondary cancers or cardiomyopathy must now be avoided at all cost. Several new breast radiotherapy techniques have been developed and this work aims at comparing the scatter doses of internal organs for those techniques.</p> <p>Methods</p> <p>A CT-scan of a typical early stage left breast cancer patient was used to describe a realistic anthropomorphic phantom in the MCNP Monte Carlo code. Dose tally detectors were placed in breasts, the heart, the ipsilateral lung, and the spleen. Five irradiation techniques were simulated: whole breast radiotherapy 50 Gy in 25 fractions using physical wedge or breast IMRT, 3D-CRT partial breast radiotherapy 38.5 Gy in 10 fractions, HDR brachytherapy delivering 34 Gy in 10 treatments, or Permanent Breast <sup>103</sup>Pd Seed Implant delivering 90 Gy.</p> <p>Results</p> <p>For external beam radiotherapy the wedge compensation technique yielded the largest doses to internal organs like the spleen or the heart, respectively 2,300 mSv and 2.7 Gy. Smaller scatter dose are induced using breast IMRT, respectively 810 mSv and 1.1 Gy, or 3D-CRT partial breast irradiation, respectively 130 mSv and 0.7 Gy. Dose to the lung is also smaller for IMRT and 3D-CRT compared to the wedge technique. For multicatheter HDR brachytherapy a large dose is delivered to the heart, 3.6 Gy, the spleen receives 1,171 mSv and the lung receives 2,471 mSv. These values are 44% higher in case of a balloon catheter. In contrast, breast seeds implant is associated with low dose to most internal organs.</p> <p>Conclusions</p> <p>The present data support the use of breast IMRT or virtual wedge technique instead of physical wedges for whole breast radiotherapy. Regarding partial breast irradiation techniques, low energy source brachytherapy and external beam 3D-CRT appear safer than <sup>192</sup>Ir HDR techniques.</p

    Correction of Gliadin Transport Within Enterocytes Through Celiac Disease Serum

    No full text
    Celiac disease (CD) is caused by loss of tolerance toward gluten and related cereal products. The delivery of gliadin peptides (GP) to HLA-DR-positive late endosomes (LE) of enterocytes is required for antigen presentation and tolerance generation. We hypothesized that anti-gliadin antibodies in CD serum modify gliadin transport into LE within enterocytes. CD and control duodenal biopsies were incubated with digests of gluten as well as with serum of CD patients. Lissamin-labeled GP AA31-43 and AA56-68 were endocytozed by Caco-2 cells with serum of CD- or control patients. Colocalization of gliadin with the LE marker LAMP-2 and cathepsin D was determined and quantified on immunofluorescence and immunoelectron microscopical level. Up to 13% of internalized gliadin was located in LE of CD biopsies incubated with CD serum compared with less than 4% in CD biopsies without CD serum as well as in control biopsies. In Caco-2 cells, the colocalization coefficient of GP AA31-43 and LE was 0.82 with CD serum, 0.42 with control serum, and 0.48 with culture medium. Incubation with CD serum can direct GP AA31-43 into LE of enterocytes which is required for antigen presentation. (Pediatr Res 70: 357-362, 2011
    corecore