2 research outputs found

    Prototipo de video frenzel-video head impulse test de bajo coste

    No full text
    Background: Since the introduction of frenzel glasses, multiple systems have been developed that allow us not only to observe the nystagmus, but also to document it, allowing us to assess its evolution and response to treat-ment, but the cost of such equipment limits its use in developing countries. Objective: Develop Video Frenzel / Video Head impulse low cost test. Materials: We use a USB video camera with night vision, a USB accelerometer / gyroscope, a standard 3 d printer, a virtual reality glasses for mobile phones and the MATLAB® software to develop the program that records eye movements and cephalic movements. We compared the prototype to the frenzel glasses by assessing a series of patients. Results: In total we included 10 patients in our study, with an average age of 62 years, the prototype allowed us to record vestibular maneuvers and assess their effectiveness. Conclusion: We have developed a low cost device with characteristics similar to commercial equipment in terms of function, weight, comfort for the patient and ease of use for the physician.Antecedentes: desde la introducción de las gafas de Frenzel se han desarrollados múltiples sistemas que permiten no permiten no solo observar el nistagmo, sino documentarlo y valorar su evolución y respuesta al tratamiento; pero el costo pero el costo de dichos equipos limita su uso en los países en vías de desarrollo. Objetivo: desarrollar un prototipo de Video Frenzel / Video Head impulse test de bajo coste. Materiales: utilizamos una cámara de video USB con visión nocturna, un acelerómetro/giroscopio USB, una impresora 3Dstandard, unas gafas de realidad virtual para móviles y el software MATLAB® para desarrollar el programa que registra los movimientos oculares y cefálicos. Comparamos el prototipo frente a las gafas de Frenzel mediante la valora-ción de una serie de pacientes. Resultados: en total incluimos 10 pacientes en nuestro estudio, con una media de edad de 62 años, el prototipo nos permitió registrar las maniobras vestibulares y valorar su eficacia

    Análisis de la marcha y el equilibrio mediante el uso de sensores inerciales: estudio prospectivo, longitudinal, no aleatorio

    No full text
    Introduction: The world population is aging rapidly. A third of those over 65 years of age falls at least once a year, and this prevalence increases by half when they exceed 69 years. Objective: To determine the sensitivity of the use of inertial sensors to determine the gait and rotations of the trunk in a group of healthy individuals. Materials: We use 3 inertial sensors of 9-axis together with the same number of microcontrollers, that sent the information via bluetooth to the computer, the data processing was carried out through an analysis program developed in MATLAB. To analyze the sensitivity of the sensors we use the protocol of Akram et al,5 modified, which consists of 5 activities. Results: In our study 6 volunteers participated, with an average age of 29 years, with an age range 25 to 33 years. The sensors were able to detect multiple variables, including the maximum and minimum elevation of the legs, number of steps, the degree of inclination of the trunk, rotation, speed and cadence. Conclusion: The results obtained are promising and we believe that the use of multiple inertial sensors to assess gait and balance could result in a new tool for the diagnosis and monitoring of people with gait and balance disorder.Antecedentes: la población mundial envejece de manera acelerada. Una tercera parte de los mayores de 65 años se cae por lo menos una vez al año, y esta prevalencia se incrementan a la mitad cuando se superan los 69 años. Objetivo: establecer la sensibilidad del uso de sensores inerciales para determinar la marcha y las rotaciones del tronco en un grupo de individuos sanos. Materiales: utilizamos tres sensores inerciales de nueve ejes, junto a un mismo número de microcontroladores, los cuales enviaron la información vía bluetooth al ordenador, el procesamiento de los datos fue realizado mediante un programa de análisis desarrollado en MATLAB. Para analizar la sensibilidad de los sensores utilizamos el protocolo de Akram et al.,5 modificado, el cual consta de cinco actividades. Resultados: en nuestro estudio participaron seis voluntarios, con una media de edad de 29 años, con un rango de edad de 25 a 33 años. Los sensores fueron capaces de detectar múltiples variables, entre ellas la elevación máxima y mínima de las piernas, número de pasos, el grado de inclinación del tronco, giro, velocidad y cadencia. Conclusión: los resultados hasta ahora obtenidos son prometedores y consideramos que el uso de múltiples sensores inerciales para valorar la marcha y el equilibrio podrían resultar en una nueva herramienta para el diagnóstico y seguimiento de personas con trastorno de la marcha y equilibrio
    corecore