129 research outputs found
On the influence of the cosmological constant on gravitational lensing in small systems
The cosmological constant Lambda affects gravitational lensing phenomena. The
contribution of Lambda to the observable angular positions of multiple images
and to their amplification and time delay is here computed through a study in
the weak deflection limit of the equations of motion in the Schwarzschild-de
Sitter metric. Due to Lambda the unresolved images are slightly demagnified,
the radius of the Einstein ring decreases and the time delay increases. The
effect is however negligible for near lenses. In the case of null cosmological
constant, we provide some updated results on lensing by a Schwarzschild black
hole.Comment: 8 pages, 1 figure; v2: extended discussion on the lens equation,
references added, results unchanged, in press on PR
Recommended from our members
A Standard format for Les Houches event files
A standard file format is proposed to store process and event information, primarily output from parton-level event generators for further use by general-purpose ones. The information content is identical with what was already defined by the Les Houches Accord five years ago, but then in terms of Fortran commonblocks. This information is embedded in a minimal XML-style structure, for clarity and to simplify parsing
Recommended from our members
Time-resolved pump-probe experiments at the LCLS
The first time-resolved x-ray/optical pump-probe experiments at the SLAC Linac Coherent Light Source (LCLS) used a combination of feedback methods and post-analysis binning techniques to synchronize an ultrafast optical laser to the linac-based x-ray laser. Transient molecular nitrogen alignment revival features were resolved in time-dependent x-ray-induced fragmentation spectra. These alignment features were used to find the temporal overlap of the pump and probe pulses. The strong-field dissociation of x-ray generated quasi-bound molecular dications was used to establish the residual timing jitter. This analysis shows that the relative arrival time of the Ti:Sapphire laser and the x-ray pulses had a distribution with a standard deviation of approximately 120 fs. The largest contribution to the jitter noise spectrum was the locking of the laser oscillator to the reference RF of the accelerator, which suggests that simple technical improvements could reduce the jitter to better than 50 fs
Breaking into Locked Rooms to Access Computer Source Code: Does the DMCA Violate a Constitutional Mandate When Technological Barriers of Access are Applied to Software?
Recommended from our members
Recent Beam Measurements and New Instrumentation at the Advanced Light Source
The Advanced Light Source (ALS) in Berkeley was the first of the soft x-ray third generation light source ever built, and since 1993 has been in continuous and successful operation serving a large community of users in the VUV and soft x-ray community. During these years the storage ring underwent through several important upgrades that allowed maintaining the performance of this veteran facility at the forefront. The ALS beam diagnostics and instrumentation have followed a similar path of innovation and upgrade and nowadays include most of the modem and last generation devices and technologies that are commercially available and used in the recently constructed third generation light sources. In this paper we will not focus on such already widely known systems, but we will concentrate our effort in the description of some measurements techniques, instrumentation and diagnostic systems specifically developed at the ALS and used during the last few years
- …