5 research outputs found

    Bench to Bed Evidences for Pharmacokinetic and Pharmacodynamic Interactions Involving Oseltamivir and Chinese Medicine

    Get PDF
    Oseltamivir (OA), an ethyl ester prodrug of oseltamivir carboxylate (OC), is clinically used as a potent and selective inhibitor of neuraminidase. Chinese medicines have been advocated to combine with conventional drug for avian influenza. The current study aims to investigate the potential pharmacokinetic and pharmacodynamic interactions of a Chinese medicine formula, namely, Yin Qiao San and Sang Ju Yin (CMF1), commonly used for anti-influenza in combination with OA in both rat and human, and to reveal the underlined mechanisms. It was found that although Cmax, AUC and urinary recovery of OC, as well as metabolic ratio (AUCOC/AUCOA), were significantly decreased in a dose-dependent manner following combination use of CMF1 and OA in rat studies (P<0.01), such coadministration in 14 healthy volunteers only resulted in a trend of minor decrease in the related parameters. Further mechanistic studies found that although CMF1 could reduce absorption and metabolism of OA, it appears to enhance viral inhibition of OA (P<0.01). In summary, although there was potential interaction between OA and CMF1 found in rat studies, its clinical impact was expected to be minimal. The coadministration of OA and CMF1 at the clinical recommended dosages is, therefore, considered to be safe

    Factors Associated with Aspirin Resistance in Hong Kong Chinese Patients with Stable Coronary Heart Disease Using the Multiplate&reg; Analyzer and Serum Thromboxane B2

    No full text
    Introduction: Aspirin resistance may be associated with various conditions. We measured serum thromboxane B2 (TXB2) and platelet function using the Multiplate&reg; Analyzer with arachidonic acid (ASPI) in patients on long term aspirin therapy to identify aspirin resistance and associated factors. Materials and Methods: Chinese patients with stable coronary heart disease had samples for serum TXB2 and ASPI measurement taken before and 1 h after taking a morning dose of 80 mg aspirin. Results: In 266 patients with mean age 66.6 &plusmn; 10.7 years, 17% were female and 55% were current or previous smokers. TXB2 and ASPI measurements were significantly higher before the dose than at 1 h post dose, with 46% of subjects having high ASPI values (AUC &gt; 300 AU*min) pre dose compared with 27% at 1 h post dose. TXB2 and ASPI measures of platelet aggregation showed weak correlations, which were only significant before the dose (r = 0.219, p = 0.001). Increased ASPI measurements were associated with white blood cell (WBC) count, haematocrit, platelet count and heart rate at 24 h post dose but only with WBC count, smoking history and heart rate at 1 h post dose. Diabetes was not associated with reduced platelet response to aspirin. The WBC count associated with aspirin resistance was over 6.55 &times; 109/L by receiver operating characteristic analysis. Conclusions: The antiplatelet response to aspirin was reduced in a large proportion of patients. Patients with higher WBC count within the normal range appear to be at increased risk of aspirin resistance. Higher or more frequent doses of aspirin may be needed in many patients

    Testing the reliability of a new ultrasonic cardiac output monitor, the USCOM, by using aortic flowprobes in anesthetized dogs

    No full text
    We have used an animal model to test the reliability of a new portable continuous-wave Doppler ultrasonic cardiac output monitor, the USCOM. In six anesthetized dogs, cardiac output was measured with a high-precision transit time ultrasonic flowprobe placed on the ascending aorta. The dogs' cardiac output was increased with a dopamine infusion (0-15 mug (.) kg(-1) (.) min(-1)). Simultaneous flowprobe and USCOM cardiac output measurements were made. Up to 64 pairs of readings were collected from each dog. Data were compared by using the Bland and Altman plot method and Lin's concordance correlation coefficient. A total of 319 sets of paired readings were collected. The mean (+/-SD) cardiac output was 2.62 +/- 1.04 L/min, and readings ranged from 0.79 to 5.73 L/min. The mean bias between the 2 sets of readings was -0.01 L/min, with limits of agreement (95% confidence intervals) of -0.34 to 0.31 L/min. This represents a 13% error. In five of six dogs, there was a high degree of concordance, or agreement, between the 2 methods, with coefficients >0.9. The USCOM provided reliable measurements of cardiac output over a wide range of values. Clinical trials are needed to validate the device in humans
    corecore