295 research outputs found

    Nasal obstruction and headache. A real correlation?

    Get PDF
    to evaluate the relationships between headache and nasal obstruction or nasal allergy on a group of Italian school children

    Alterations in rhinosinusal homeostasis in a sportive population: our experience with 106 athletes

    Get PDF
    The aim of the present work was to analyse the alterations of rhino-sinusal physiology in 106 professional athletes (swimmers, skiers, boxers and runners) using objective rhinological methods. Every athlete underwent an accurate anamnesis, a complete objective ORL evaluation, an active anterior rhinomanometry, an acoustic rhinometry and an evaluation of mucociliary transport time (MCTt). Skiers were also submitted to a nasal decongestion test (NDT). In swimmers, the mean MCTt was 27.4+/-4.97 min (normal value: 13+/-3 min; P<0.0001). The average MCTt for the skier group was 19.58+/-1.92 min ( P<0.0001); the mean value of total basal nasal resistance was 0.37+/-0.05 Pa/ml per s (normal value =0.25 Pa/ml per s; P<0.001). After NDT, total nasal resistance was 0.18+/-0.02 Pa/ml per s. In the group of boxers, the total mean nasal resistance was 0.64+/-0.05 Pa/ml per s ( P<0.001); the mean cross-sectional area at the nasal valve level was 0.57+/-0.04 cm(2) (normal value =0.55+/-0.05 cm(2)) and at the inferior turbinate level 0.83+/-0.05 cm(2) (normal value =0.4+/-0.04 cm(2); P<0.001); the TMC average time was 27.35+/-2.21 min ( P<0.0001). Finally, for the runners, the mean MCT time was 20.56+/-2.35 min ( P<0.001). Knowing the alterations of the physiological nasal respiration is of extreme importance to develop a correct and timely therapeutic approach to be able to restore rhino-sinusal homeostasis. Athletes, in fact, need the earliest therapeutic aid in order to avoid the interference of prolonged rhino-sinusal alterations with their performance and also to avoid a more serious clinical situation concerning the inferior airways

    The impact of allergic rhinitis in clinical practice: an italian survey

    Get PDF
    Allergic rhinitis (AR) is a very common disorder. The current Survey was conducted on a sample of about 5,000 adult subjects in 5 Italian cities. A questionnaire, containing 15 questions, was administered on the road. AR affects about 20% of the general population. The most common diagnostic test was the skin prick test, but only 12% of patients performed an allergy test to confirm the diagnosis. About 50% of patients did not take any medicine. Even about 40% of treatments were suggested by friends or pharmacists. In conclusion, the current Survey demonstrated that AR is a common disorder in Italy, the diagnostic work-up is still incorrect, and the therapeutic approach does not adhere to the guidelines. Therefore, there is a need to implement adequate information on this topic in Italy

    Sonographic knowledge of occiput position to decrease failed operative vaginal delivery: a systematic review and meta-analysis of randomized controlled trials

    Get PDF
    Objective: This study aimed to assess the efficacy of sonographic assessment of fetal occiput position before operative vaginal delivery to decrease the number of failed operative vaginal deliveries. Data Sources: The search was conducted in MEDLINE, Embase, Web of Science, Scopus, ClinicalTrial.gov, Ovid, and Cochrane Library as electronic databases from the inception of each database to April 2021. No restrictions for language or geographic location were applied. Study Eligibility Criteria: Selection criteria included randomized controlled trails of pregnant women randomized to either sonographic or clinical digital diagnosis of fetal occiput position during the second stage of labor before operative vaginal delivery. Methods: The primary outcome was failed operative vaginal delivery, defined as a failed fetal operative vaginal delivery (vacuum or forceps) extraction requiring a cesarean delivery or forceps after failed vacuum. The summary measures were reported as relative risks or as mean differences with 95% confidence intervals using the random effects model of DerSimonian and Laird. An I2 (Higgins I2) &gt;0% was used to identify heterogeneity. Results: A total of 4 randomized controlled trials including 1007 women with singleton, term, cephalic fetuses randomized to either the sonographic (n=484) or clinical digital (n=523) diagnosis of occiput position during the second stage of labor before operative vaginal delivery were included. Before operative vaginal delivery, fetal occiput position was diagnosed as anterior in 63.5% of the sonographic diagnosis group vs 69.5% in the clinical digital diagnosis group (P=.04). There was no significant difference in the rate of failed operative vaginal deliveries between the sonographic and clinical diagnosis of occiput position groups (9.9% vs 8.2%; relative risk, 1.14; 95% confidence interval, 0.77–1.68). Women randomized to sonographic diagnosis of occiput position had a significantly lower rate of occiput position discordance between the evaluation before operative vaginal delivery and the at birth evaluation when compared with those randomized to the clinical diagnosis group (2.3% vs 17.7%; relative risk, 0.16; 95% confidence interval, 0.04–0.74; P=.02). There were no significant differences in any of the other secondary obstetrical and perinatal outcomes assessed. Conclusion: Sonographic knowledge of occiput position before operative vaginal delivery does not seem to have an effect on the incidence of failed operative vaginal deliveries despite better sonographic accuracy in the occiput position diagnosis when compared with clinical assessment. Future studies should evaluate how a more accurate sonographic diagnosis of occiput position or other parameters can lead to a safer and more effective operative vaginal delivery technique

    Atomized nasal douche vs nasal lavage in acute viral rhinitis

    Get PDF
    To evaluate the efficacy of the atomized nasal douche in the restoration of physiological nasal functions in patients affected by acute viral rhinosinusitis, when compared with nasal lavages with isotonic sodium chloride solution

    Wettability of soft PLGA surfaces predicted by experimentally augmented atomistic models

    Get PDF
    A challenging topic in surface engineering is predicting the wetting properties of soft interfaces with different liquids. However, a robust computational protocol suitable for predicting wettability with molecular precision is still lacking. In this article, we propose a workflow based on molecular dynamics simulations to predict the wettability of polymer surfaces and test it against the experimental contact angle of several polar and nonpolar liquids, namely water, formamide, toluene, and hexane. The specific case study addressed here focuses on a poly(lactic-co-glycolic acid) (PLGA) flat surface, but the proposed experimental-modeling protocol may have broader fields of application. The structural properties of PLGA slabs have been modeled on the surface roughness determined with microscopy measurements, while the computed surface tensions and contact angles were validated against standardized characterization tests, reaching a discrepancy of less than 3% in the case of water. Overall, this work represents the initial step toward an integrated multiscale framework for predicting the wettability of more complex soft interfaces, which will eventually take into account the effect of surface topology at higher scales and synergically be employed with experimental characterization techniques

    Treatment of recurrent chronic hyperplastic sinusitis with nasal polyposis

    Get PDF
    To demonstrate the long-term efficacy of intranasal furosemide, an inhibitor of the sodium chloride cotransporter channel at the basolateral surface of the respiratory epithelial cell, vs no therapeutic intervention vs intranasal mometasone furoate, a corticosteroid, in preventing relapses of chronic hyperplastic sinusitis with nasal polyposis

    Stress ossidativo nei pazienti con diagnosi di sindrome delle apnee ostruttive notturne

    Get PDF
    La Sindrome delle Apnee Ostruttive Notturne (OSAS) è una patologia caratterizzata da alterazioni metaboliche e da un elevato rischio di sviluppo di patologie cardiovascolari. Lo scopo dello studio è stato quello di identificare dei markers precoci predittivi di rischio cardiovascolare con la valutazione dello stress ossidativo misurato attraverso esami di laboratorio in soggetti normali e pazienti con diagnosi di sindrome delle apnee ostruttive notturne. È stato effettuato uno studio prospettico per confrontare i risultati di laboratorio ottenuti dalla valutazione dei biomarkers dello stress ossidativo in 20 pazienti adulti con OSAS e 20 soggetti sani. Le tecniche di analisi utilizzate avevano l’obiettivo di identificare e quantificare i danni dei radicali liberi attraverso la misurazione di anti-ossidanti e pro-ossidanti in modo da valutare l’equilibrio ossidativo presente nei due gruppi di studio. I due gruppi di pazienti sono risultati omogeni per sesso, età ed indice di massa corporea (p < 0,05). Una differenza statisticamente significativa è stata individuata tra i livelli di indice di apnea-ipopnea valutata alla polisonnografia e di isoprostani, produzione di proteine di ossidazione e proteine non legate al ferro nei due gruppi in esame. Nessuna differenza significativa è stata trovata nel livello dei tioli tra i soggetti sani e i pazienti con sindrome delle apnee ostruttive. I tioli, a differenza degli altri markers, sono molecole anti-ossidanti, i restanti sono invece espressione di danno ossidativo. I risultati dello studio indicano che i biomarkers potrebbero essere utilizzati come indici di ostruzione delle vie aeree superiori (VAS) e come marcatori precoci di ipossiemia causando processi flogistici ricorrenti e danno locale da radicali liberi a carico delle VAS

    Improved THETA-1 for light olefins oligomerization to diesel: Influence of textural and acidic properties

    Full text link
    The increase in diesel demand, especially in Europe, and the need for high fuel quality requirements are forcing refiners to move into additional processes for production of high cetane diesel in order to meet the present market trends. Oligomerization of light olefins into middle distillate range products is a viable option. The fuel produced through this technology is environmentally friendly, free of sulfur and aromatics, and the adequate choice of the heterogeneous catalyst will direct the selectivity towards low branched oligomers, which will result in a high quality product. In this work we show the benefits of combining basic desilication treatments for generation of additional mesoporosity in mono-directional Theta-1 zeolite, with selective acid dealumination steps that restore not only the microporosity to values close to those of the parent samples, but also the total and strong Bronsted acidity. These modified Theta-1 zeolites present an outstanding catalytic behavior for oligomerization of propene, with a largely increased initial activity, a much higher resistance to deactivation with time on stream, and an improved selectivity to products in the diesel fraction, as compared to the original microporous Theta-1.The authors thank BP Products of North America for their financial support and permission to publish this work, and Consolider Ingenio 2010-Multicat, the "Severo Ochoa Program", and MAT2012-31657 for financial support. R. Sanchis is acknowledged for technical support.Martínez, C.; Doskocil, EJ.; Corma Canós, A. (2014). Improved THETA-1 for light olefins oligomerization to diesel: Influence of textural and acidic properties. Topics in Catalysis. 57(6-9):668-682. https://doi.org/10.1007/s11244-013-0224-xS668682576-9Bellussi G, Mizia F, Calemma V, Pollesel P, Millini R (2012) Microporous Mesoporous Mater 164:127–134Bellussi G, Carati A, Millini R (2010) In: Cejka J, Corma A, Zones S (eds) Zeolites and Catalysis. Wiley-VCH Verlag GmbH & Co., Weinheim, pp 449–491Martinez C, Corma A (2011) Coord Chem Rev 255:1558–1580de Klerk A (2005) Ind Eng Chem Res 44:3887–3893de Klerk A (2006) Energy Fuels 20:439–445de Klerk A (2006) Energy Fuels 20:1799–1805Egloff G (1936) Ind Eng Chem Res 28:1461–1467Degnan TF Jr, Smith CM, Venkat CR (2001) Appl Catal A Gen 221:283–294Apelian MR, Boulton JR, Fung AS (1994) US5284989, to Mobil OilQuann RJ, Green LA, Tabak SA, Krambeck FJ (1988) Ind Eng Chem Res 27:565–570Tabak SA, Krambeck FJ, Garwood WE (1986) AIChE J 32:1526–1531Corma A, Martínez C, Doskocil EJ (2013) J Catal 300:183–196Martens JA, Ravishankar R, Mishin IE, Jacobs PE (2000) Angew Chem Int Ed Engl 39:4376–4379Martens JA, Verrelst WH, Mathys GM, Brown SH, Jacobs PA (2005) Angew Chem Int Ed Engl 117(5833–583):6Pater JPG, Jacobs PA, Martens JA (1998) J Catal 179:477–482Tabak SA (1981) US4254295, to Mobil OilOccelli ML, Hsu JT, Galya LG (1985) J Mol Catal A: Chem 32:377–390Tabak SA (1984) US4504693, to Mobil Oil CorpKholer E, Schmidt F, Wernicke HJ, Pontes MD, Roberts HL (1995, Summer) Hydrocarbon Technology InternationalMartens JA, Verduijn JP (1995) WO95/19945, to Exxon Chemical Patents Inc.Verrelst WH (1995) Martens LRM, WO95/22516, to Exxon Chemical Patents Inc.Verrelst WH, Martens LRM (2000) US6143942, to Exxon Chemical Patents Inc.Verrelst WH, Martens LRM, Verduijn JP (2006) US6013851, to Exxon Chemical Patents Inc.Dakka JM, Mathys GMK, Puttemans MPH (2003) WO03/035583 to Exxon-Mobil Chemical LimitedMatias P, Sa CC, Graca I, Lopes JM, Carvalho AP, Ramoa RF, Guisnet M (2011) Appl Catal A 399:100–109Chal R, Gérardin C, Bulut M, van Donk S (2011) ChemCatChem 3:67–81Perez-Ramirez J, Christensen CH, Egeblad K, Groen JC (2008) Chem Soc Rev 37:2530–2542Verboekend D, Perez-Ramirez J (2011) Catal Sci Technol 1:879–890Serrano DP, Escola JM, Pizarro P (2013) Chem Soc Rev 42:4004–4035Verboekend D, Chabaneix AM, Thomas K, Gilson JP, Perez-Ramirez J (2011) Cryst Eng Comm 13:3408–3416Emeis CA (1993) J Catal 141:347–354Perego C, Peratello S (1999) Catal Today 52:133–145Abello S, Bonilla A, Perez-Ramirez J (2009) Appl Catal A Gen 364:191–198Corma A, Martinez C, Doskocil EJ, Yaluris G (2011) WO2011002631A2, to BP Oil International Limited. BP Corporation North America Inc., UKCorma A, Martinez C, Doskocil EJ, Yaluris G (2011) WO2011002630A2, to BP Oil International Limited. BP Corporation North America Inc, UKHan S, Heck RH, DiGuiseppi FT (1993) US5234875, to Mobil Oil CorporationPeratello S, Molinari M, Bellussi G, Perego C (1999) Catal Today 52:271–27
    • …
    corecore