    Accuracy of computed tomography perfusion in assessing metastatic involvement of enlarged axillary lymph nodes in patients with breast cancer

    Get PDF
    Introduction: The purpose of this study was to evaluate the diagnostic accuracy of computed tomography (CT) perfusion in differentiating metastatic from inflammatory enlarged axillary lymph nodes in patients with breast cancer. Methods: Twenty-five patients with 26 locally advanced breast tumors and clinically palpable axillary lymph nodes underwent dynamic multi-detector CT (LightSpeed 16; General Electric Company) at one scan per second for 150 seconds at the same table position after 40 ml intravenous contrast injection at 4.0 ml/second. Semi-automatic calculation of values of perfusion parameters - blood flow (BF), blood volume (BV), mean transit time (MTT), and permeability surface (PS) - was performed. Results were compared with pathology and with Her-2/neu and Ki-67 levels in a surgical specimen of the primary tumor. Results: Examined lymph nodes were inflammatory in 8 cases and metastatic in 18. Mean values of perfusion parameters in inflammatory and metastatic nodes, respectively, were BF of 76.18 (confidence interval [CI], 31.53) and 161.60 (CI, 40.94) ml/100 mg per minute (p < 0.05), BV of 5.81 (CI, 2.50) and 9.15 (CI, 3.02) ml/100 mg (not significant [n.s.]), MTT of 6.80 (CI, 1.55) and 5.50 (CI, 1.84) seconds (p = 0.07), and PS of 25.82 (CI, 4.62) and 25.96 (CI, 7.47) ml/100 mg per minute (n.s.). Size of nodes, stage of breast cancer, Ki-67 and Her-2/neu levels in breast cancer, and expression of primary tumor activity were not correlated to any perfusion parameter in metastatic nodes. Conclusion: CT perfusion might be an effective tool for studying enlarged axillary lymph nodes in patients with breast cancer. It gives information on vascularization of lymph nodes, helping to understand the changes occurring when neoplastic cells implant in lymph nodes

    Positron emission tomography in the diagnostic work-up of screening-detected lung nodules

    Get PDF
    Low-dose computed tomography (CT) screening for lung cancer can reduce lung cancer mortality, but overdiagnosis, false positives and invasive procedures for benign nodules are worrying. We evaluated the utility of positron emission tomography (PET)-CT in characterising indeterminate screeningdetected lung nodules. 383 nodules, examined by PET-CT over the first 6 years of the COSMOS (Continuous Observation of Smoking Subjects) study to diagnose primary lung cancer, were reviewed and compared with pathological findings (surgically-treated patients) or follow-up (negative CT for â\u89¥2 years, considered negative); 196 nodules were malignant. The sensitivity, specificity and accuracy of PET-CT for differentially diagnosing malignant nodules were, respectively, 64%, 89% and 76% overall, and 82%, 92% and 88% for baseline-detected nodules. Performance was lower for nodules found at repeat annual scans, with sensitivity ranging from 22% for nonsolid to 79% for solid nodules (p=0.0001). Sensitivity (87%) and specificity (73%) were high for nodules â\u89¥15 mm, better (sensitivity 98%) for solid nodules â\u89¥15 mm. PET-CT was highly sensitive for the differential diagnosis of indeterminate nodules detected at baseline, nodules â\u89¥15 mm and solid nodules. Sensitivity was low for sub-solid nodules and nodules discovered after baseline for which other methods, e.g. volume doubling time, should be used

    The Outcome of Cholangitis After Percutaneous Biliary Drainage in Neoplastic Jaundice

    Get PDF
    The purpose of this paper is to evaluate factors affecting the outcome of cholangitis after PTBD in jaundiced cancer patients. Twenty nine patients with neoplastic jaundice (male/female ratio 13/16, median age 55 years) with full clinical data, were treated by PTBD and developed cholangitis at a median of 9 days later. Four patients (14%) died of biliary sepsis a median of one month after PTBD while the other 25 survived a median of 6 months, with one week median duration of cholangitis. The probability of the cholangitis resolving was analyzed by time to resolution and it was found that 50% and 100% of the recoveries occurred 5 and 9 months respectively from the onset of the complication

    Anterior prostatic tumours are difficult to diagnose without MRI

    Get PDF
    It is often uncertain whether a repeat biopsy is necessary in patients with at least one previous negative prostate biopsy but persistent suspicion of prostate cancer. Here we present the use of multi-parametric magnetic resonance imaging (mp-MRI) to successfully detect and localize a prostate cancer and we suggest that MRI can be useful in optimising repeat biopsy procedures of the prostate in patients with clinically significant carcinoma

    Magnetic resonance mammography in the evaluation of recurrence at the prior lumpectomy site after conservative surgery and radiotherapy

    Get PDF
    INTRODUCTION: The aim was to assess the value of magnetic resonance mammography (MRM) in the detection of recurrent breast cancer on the prior lumpectomy site in patients with previous conservative surgery and radiotherapy. METHODS: Between April 1999 and July 2003, 93 consecutive patients with breast cancer treated with conservative surgery and radiotherapy underwent MRM, when a malignant lesion on the site of lumpectomy was suspected by ultrasound and/or mammography. MRM scans were evaluated by morphological and dynamic characteristics. MRM diagnosis was compared with histology or with a 36-month imaging follow-up. Enhancing areas independent of the prior lumpectomy site, incidentally detected during the MRM, were also evaluated. RESULTS: MRM findings were compared with histology in 29 patients and with a 36-month follow-up in 64 patients. MRM showed 90% sensitivity, 91.6% specificity, 56.3% positive predictive value and 98.7% negative predictive value for detection of recurrence on the surgical scar. MRM detected 13 lesions remote from the scar. The overall sensitivity, specificity, positive predictive value and negative predictive value of MRM for detection of breast malignancy were 93.8%, 90%, 62.5% and 98.8%, respectively. CONCLUSION: MRM is a sensitive method to differentiate recurrence from post-treatment changes at the prior lumpectomy site after conservative surgery and radiation therapy. The high negative predictive value of this technique can avoid unnecessary biopsies or surgical treatments

    Sensitivity of imaging for multifocal-multicentric breast carcinoma

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>This retrospective study aims to determine: 1) the sensitivity of preoperative mammography (Mx) and ultrasound (US), and re-reviewed Mx to detect multifocal multicentric breast carcinoma (MMBC), defined by pathology on surgical specimens, and 2) to analyze the characteristics of both detected and undetected foci on Mx and US.</p> <p>Methods</p> <p>Three experienced breast radiologists re-reviewed, independently, digital mammography of 97 women with MMBC pathologically diagnosed on surgical specimens. The radiologists were informed of all neoplastic foci, and blinded to the original mammograms and US reports. With regards to Mx, they considered the breast density, number of foci, the Mx characteristics of the lesions and their BI-RADS classification. For US, they considered size of the lesions, BI-RADS classification and US pattern and lesion characteristics. According to the histological size, the lesions were classified as: index cancer, 2nd lesion, 3rd lesion, and 4th lesion. Any pathologically identified malignant foci not previously described in the original imaging reports, were defined as undetected or missed lesions. Sensitivity was calculated for Mx, US and re-reviewed Mx for detecting the presence of the index cancer as well as additional satellite lesions.</p> <p>Results</p> <p>Pathological examination revealed 13 multifocal and 84 multicentric cancers with a total of 303 malignant foci (282 invasive and 21 non invasive). Original Mx and US reports had an overall sensitivity of 45.5% and 52.9%, respectively. Mx detected 83/97 index cancers with a sensitivity of 85.6%. The number of lesions <it>un</it>detected by original Mx was 165/303. The Mx pattern of breasts with undetected lesions were: fatty in 3 (1.8%); scattered fibroglandular density in 40 (24.3%), heterogeneously dense in 91 (55.1%) and dense in 31 (18.8%) cases. In breasts with an almost entirely fatty pattern, Mx sensitivity was 100%, while in fibroglandular or dense pattern it was reduced to 45.5%. Re-reviewed Mx detected only 3 additional lesions. The sensitivity of Mx was affected by the presence of dense breast tissue which obscured lesions or by an incorrect interpretation of suspicious findings.</p> <p>US detected 73/80 index cancers (sensitivity of 91.2%), US missed 117 malignant foci with a mean tumor diameter of 6.5 mm; the sensitivity was 52.9%</p> <p>Undetected lesions by US were those smallest in size and present in fatty breast or in the presence of microcalcifications without a visible mass.</p> <p>US sensitivity was affected by the presence of fatty tissue or by the extent of calcification.</p> <p>Conclusion</p> <p>Mx missed MMBC malignant foci more often in dense or fibroglandular breasts. US missed small lesions in mainly fatty breasts or when there were only microcalcifications. The combined sensitivity of both techniques to assess MMBC was 58%. We suggest larger studies on multimodality imaging.</p

    European Institute of Oncology project for lung cancer screening

    No full text

    Imaging techniques to diagnose radiation damage