57 research outputs found

    Subclinical postoperative atrial fibrillation: a randomized trial

    Get PDF
    BackgroundPostoperative atrial fibrillation (POAF) is the most common complication of cardiac surgery, requiring interventions and prolonging hospital stay. POAF is associated with increased mortality and a higher rate of systemic thrombo-embolism. The rates of recurrent AF, optimal follow-up and management remain unclear. We aimed to evaluate the incidence of recurrent atrial fibrillation (AF) events, during long term follow-up in patients with POAF following cardiac surgery.MethodsPatients with POAF and a CHA2DS2-VASc score of ≥2 were randomized in a 2:1 ratio to either implantation of a loop recorder (ILR) or ECG monitoring using periodic Holters. Participants were followed prospectively for 2 years. The primary end point was the occurrence of AF longer than 5 min.ResultsThe final cohort comprised of 22 patients, of whom 14 received an ILR. Over a median follow up of 25.7 (IQR of 24.7–44.4) months, 8 patients developed AF, representing a cumulative annualized risk of AF recurrence of 35.7%. There was no difference between ILR (6 participants, 40%) and ECG/Holter (2 participants, 25% p = 0.917). All 8 patients with AF recurrence were treated with oral anticoagulation. There were no cases of mortality, stroke or major bleeding. Two patients underwent ILR explantation due to pain at the implantation site.ConclusionsThe rate of recurrent AF in patients with POAF after cardiac surgery and a CHA2DS2-VASc score of ≥2 is approximately 1 in 3 when followed systematically. Further research is need to assess the role of ILRs in this population

    Cold water induced pulmonary edema

    No full text

    Long-Term Outcomes of Tachycardia-Induced Cardiomyopathy Compared with Idiopathic Dilated Cardiomyopathy

    No full text
    Background: data on the natural course and prognosis of tachycardia-induced cardiomyopathy (TICMP) and comparison with idiopathic dilated cardiomyopathies (IDCM) are scarce. Objective: To compare the clinical presentation, comorbidities, and long-term outcomes of TICMP patients with IDCM patients. Methods: a retrospective cohort study of patients hospitalized with new-onset TICMP or IDCM. The primary endpoint was a composite of death, myocardial infarction, thromboembolic events, assist device, heart transplantation, and ventricular tachycardia or fibrillation (VT/VF). The secondary endpoint was recurrent hospitalization due to heart failure (HF) exacerbation. Results: the cohort was comprised of 64 TICMP and 66 IDCM patients. The primary composite endpoint and all-cause mortality were similar between the groups during a median follow-up of ~6 years (36% versus 29%, p = 0.33 and 22% versus 15%, p = 0.15, respectively). Survival analysis showed no significant difference between TICMP and IDCM groups for the composite endpoint (p = 0.75), all-cause mortality (p = 0.65), and hospitalizations due to heart failure exacerbation. Nonetheless, the incidence of recurrent hospitalization was significantly higher in TICMP patients (incidence rate ratio 1.59; p = 0.009). Conclusions: patients with TICMP have similar long-term outcomes as those with IDCM. However, it portends a higher rate of HF readmissions, mostly due to arrhythmia recurrences

    Long-Term Outcomes of Tachycardia-Induced Cardiomyopathy Compared with Idiopathic Dilated Cardiomyopathy

    No full text
    Background: data on the natural course and prognosis of tachycardia-induced cardiomyopathy (TICMP) and comparison with idiopathic dilated cardiomyopathies (IDCM) are scarce. Objective: To compare the clinical presentation, comorbidities, and long-term outcomes of TICMP patients with IDCM patients. Methods: a retrospective cohort study of patients hospitalized with new-onset TICMP or IDCM. The primary endpoint was a composite of death, myocardial infarction, thromboembolic events, assist device, heart transplantation, and ventricular tachycardia or fibrillation (VT/VF). The secondary endpoint was recurrent hospitalization due to heart failure (HF) exacerbation. Results: the cohort was comprised of 64 TICMP and 66 IDCM patients. The primary composite endpoint and all-cause mortality were similar between the groups during a median follow-up of ~6 years (36% versus 29%, p = 0.33 and 22% versus 15%, p = 0.15, respectively). Survival analysis showed no significant difference between TICMP and IDCM groups for the composite endpoint (p = 0.75), all-cause mortality (p = 0.65), and hospitalizations due to heart failure exacerbation. Nonetheless, the incidence of recurrent hospitalization was significantly higher in TICMP patients (incidence rate ratio 1.59; p = 0.009). Conclusions: patients with TICMP have similar long-term outcomes as those with IDCM. However, it portends a higher rate of HF readmissions, mostly due to arrhythmia recurrences

    Can the Norton Scale Score Be Used as an Adjunct Tool for Implantable Defibrillator Patient Selection? A Retrospective Single-Center Cohort Study

    No full text
    (1) Background: Implantable cardioverter defibrillators (ICDs) have become the standard of care in the prevention of sudden cardiac death, yet studies have shown that competing causes of death may limit ICD benefits. The Norton scale is a pressure ulcer risk score shown to have prognostic value in other fields. The purpose of this study was to assess the use of the Norton scale as an aid for ICD patient selection; (2) Methods: The study was comprised of consecutive patients who underwent defibrillator implantation at Sheba Medical Center between 2008 and 2016. A competing risk analysis was performed to assess the likelihood of death prior to device therapy; (3) Results: 695 patients were included. A total of 59 (8.5%) patients had low admission Norton scale score (ANSS) (≤14), 81 (11.7%) had intermediate ANSS (15–17), and the remainder (79.8%) had high (18–20) ANSS. The cumulative probability of all-cause mortality within one year of ICD implantation in patients with low ANSS was 30%, compared with 20% and 7% among the intermediate- and high-ANSS groups, respectively. Moreover, the one-year mortality rate without ICD therapy in low-ANSS patients was over four-fold compared with that of high-ANSS patients (33% versus 7%, p < 0.0001); (4) Conclusions: The Norton scale could be a useful additional tool in predicting the life expectancy of ICD candidates, thereby improving patient selection

    Transvenous lead extraction with laser reduces need for femoral approach during the procedure.

    No full text
    IntroductionCardiac implantable electronic device (CIED) trans venous lead extraction (TLE) is technically challenging. Whether the use of a laser sheath reduces complications and improves outcomes is still in debate. We therefore aimed at comparing our experience with and without laser in a large referral center.MethodsInformation of all patients undergoing TLE was collected prospectively. We retrospectively compared procedural outcomes prior to the introduction of the laser sheath lead extraction technique to use of laser sheath.ResultsDuring the years 2007-2017, there were 850 attempted lead removals in 407 pts. Of them, 339 (83%) were extracted due to infection, device upgrade/lead malfunction in 42 (10%) cases, and other (7%). Complete removal (radiological success) of all leads was achieved in (88%). Partial removal was achieved in another 6% of the patients. Comparison of cases prior to and after laser technique introduction, showed that with laser, a significantly smaller proportion of cases required conversion to femoral approach [31/275 (6%) laser vs. 40/132 (15%) non-laser; pConclusionIntroduction of laser lead removal resulted in decreased need to convert to femoral approach, albeit without improving success rates or preventing major complications
    • …
    corecore