51 research outputs found

    Management of Transhepatic Cholangioscopy: A Case Series

    Get PDF
    Presented at the 2022 Virtual Northwest Medical Research Symposiu

    Percutaneous Interventional Radiology-Operated Endoscopy for Foreign Body Removal

    Get PDF
    Image-guided retrieval of endovascular devices such as inferior vena cava filters, guidewires, and stents is well reported, though there is a paucity of published reports on biliary, genitourinary, or gastrointestinal foreign body retrieval utilizing percutaneous endoscopy, particularly when it is performed solely by interventional radiologists. In cases of failed traditional endoscopic techniques or to evade more invasive surgical options, percutaneous endoscopy can be an adjunctive tool employed by interventional radiologists to extract foreign bodies. In this article, clinical evaluation, perioperative management, and procedural techniques for biliary, genitourinary, and gastrointestinal endoscopy for foreign body retrieval are reviewed

    Billing, Coding, and Credentialing for Interventional Radiology-Operated Endoscopy

    Get PDF
    A sound understanding of billing and coding is essential to start a successful interventional radiology endoscopy practice. While the codes utilized are similar to gastrointestinal and genitourinary endoscopy codes, physicians and institutional coders need to be familiar with the codes used for these types of procedures in the interventional radiology setting. The following manuscript gives a brief overview of aspects relating to credentialing, billing, and coding in interventional radiology endoscopy

    N-butyl cyanoacrylate embolotherapy: techniques, complications, and management

    Get PDF
    The purpose of this article is to describe acute complications associated with adhesive cyanoacrylate deposition in the peripheral circulation and their management. Despite best efforts, n-butyl cyanoacrylate glue embolization is inherently unpredictable and complications do occur. An understanding of preparation techniques that minimize adverse event rates and the technical skillset required to manage complications are necessary for the safe and efficient use of liquid embolic agents

    Collaboration is Key – Bridging the Gap and Building an IR Endoscopy Practice

    Get PDF
    While the tools and techniques employed by interventional radiologists on a day-to-day basis translate well to learning the skills required to perform basic endoscopic interventions, collaboration with other specialties is crucial to the success of an interventional radiology endoscopy program. As in any field in medicine, the paramount goal is to improve patient care. Adding the ability to directly visualize structures through an endoscope to certain interventional radiologic procedures may greatly augment the efficacy, safety, and success of interventional radiology procedures. Colleagues in urology, gastroenterology, and surgery should be involved in decision-making and treatment planning to ensure that a shared vision for optimal patient care is achieved

    Percutaneous transgastrostomic interventional radiology-operated endoscopy facilitates foreign body removal using rigid endobronchial forceps

    Get PDF
    Retained foreign bodies within the stomach and proximal small bowel may be problematic in patients with prior cerebrovascular injury or head, neck and esophageal malignancy, given the increased vulnerability of this patient population to complications from aspiration and increased difficulty of esophagogastroduodenoscopy in cases of tumoral obstruction. This article presents an alternative method for foreign body retrieval through an existing gastrostomy tract, which offers the benefits of fast procedure times, reduction in radiation dose and fluoroscopy time, and allows for safer retrieval of foreign bodies by using direct visualization. This technique may be performed entirely by interventional radiologists

    Fibrillar collagen injection for organ protection during thermal ablation of hepatic malignancies

    Get PDF
    Percutaneous image-guided ablation is performed throughout many areas of the body for various pathologies including hepatic malignancies. Heat and cold-based ablative technologies are effective and well-tolerated with an acceptable safety profile. However, ablative therapies may be technically more challenging and cause collateral thermal injury if the targeted lesion is adjacent to critical organs. Previously, techniques including artificial ascites and pneumoperitoneum have been utilized to displace or insulate critical structures from the ablation zone. This technical innovation describes (10–30 mL) fibrillar collagen dissolved in fluid as a focal thermal insulation technique. Small volume fibrillar collagen instillation, and thermal ablation were technically successful in three cases without complication. Clinical follow-up and 3-month imaging confirmed complete ablation of all hepatic malignancies without collateral injury

    Prone transradial catheterization for combined single-session endovascular and percutaneous interventions: approach, technical success, safety, and outcomes in 15 patients

    Get PDF
    PURPOSE:We aimed to report approach, safety, technical success, and clinical outcomes of prone trans- radial access (PTRA) and demonstrate feasibility for procedures requiring simultaneous arterial intervention and prone percutaneous access. METHODS:Fifteen patients underwent PTRA, seven females (47%) and eight males (53%), mean age of 55 years (range, 19–78 years). All patients underwent PTRA for combined transarterial and posterior-approach percutaneous interventions. Variables included sheath size (French, F), type of anesthesia, arterial intervention technical success, posterior-approach percutaneous intervention technical success, estimated blood loss (mL), fluoroscopy and procedure time, complications, and follow-up.RESULTS:Mean sheath size was 4 F (range, 4–6 F; SD = 0.5). Arterial interventions included transarterial embolization of renal (n=6), hepatic (n=2), and pelvic vessels (n=2), diagnostic arteriography (n=4), and embolization of an arteriovenous malformation (n=1). Posterior-approach intervention technical success was 100% (15/15). PTRA technical success was 100% (15/15). Posterior-approach percutaneous interventions included retroperitoneal (n=5) and pelvic (n=1) mass biopsies, nephrostomy tube placement (n=2), cryoablation of pelvic (n=2) and renal (n=1) masses, sclerotherapy of arteriovenous malformations (n=2), foreign body removal from the renal collecting system (n=2), ablation of a renal tumor (n=1), intracavitary injection of pulmonary mycetoma (n=1), and ablation and cementoplasty of a vertebral body tumor (n=1). The biopsies were diagnostic (6/6). There were no minor or major access-site complications.CONCLUSION:PTRA is a safe and feasible method for performing combined arterial and posterior approach percutaneous interventions without the need for repositioning

    Gianturco Z-stent placement for the treatment of chronic central venous occlusive disease: implantation of 208 stents in 137 symptomatic patients

    Get PDF
    PURPOSETo report the technical successes, adverse events, and long-term stent patency rates of Gianturco Z-stents for management of chronic central venous occlusive disease.METHODSOverall, 137 patients, with mean age 48.6±16.1 years (range, 16-89 years), underwent placement of Gianturco Z-stents for chronic central venous occlusions. Presenting symptoms included lower extremity edema (n=66, 48.2%), superior vena cava syndrome (n=30, 21.9%), unilateral upper extremity swelling (n=20, 14.6%), hemodialysis fistula or catheter dysfunction (n=11, 8.0%), ascites (n=8, 5.8%), and both ascites and lower extremity edema (n=2, 1.5%). Most common etiologies of central venous occlusion were prior central venous access placement (n=58, 42.3%), extrinsic compression (n=29, 21.2%), and post-surgical anastomotic stenosis (n=27, 19.7%). Number of stents placed, stent implantation location, stent sizes, technical successes, adverse events, need for re-intervention, follow-up evaluation, stent patencies, and mortality were recorded. Technical success was defined as recanalization and stent reconstruction with restoration of in-line venous flow. Adverse events were defined by the Society of Interventional Radiology Adverse Event Classification criteria. Primary and primary-assisted stent patencies were analyzed using Kaplan-Meier analysis.RESULTSIn total, 208 Z-stents were placed. The three most common placement sites were the inferior vena cava (n=124, 59.6%), superior vena cava (n=44, 21.2%), and brachiocephalic veins (n=27, 13.0%). Technical success was achieved in 133 patients (97.1%). There were two (1.5%) severe adverse events (two cases of stent migration to the right atrium), one (0.7%) moderate adverse event, and one (0.7%) mild adverse event. Mean follow-up was 43.6±52.7 months. Estimated 1-, 3-, and 5-year primary stent patency was 84.2%, 84.2%, and 82.1%, respectively. Estimated 1-, 3-, and 5-year primary-assisted patency was 92.3%, 89.6%, and 89.6%, respectively. The 30- and 60- day mortality rates were 2.9% (n=4) and 5.1% (n=7), none of which were directly attributable to Z-stent placement.CONCLUSIONGianturco Z-stent placement is safe and effective for the treatment for chronic central venous occlusive disease with durable short- and long-term patencies
    • …
    corecore