108 research outputs found

    Scintigraphic assessment of bone status at one year following hip resurfacing : comparison of two surgical approaches using SPECT-CT scan

    Get PDF
    Objectives: To study the vascularity and bone metabolism of the femoral head/neck following hip resurfacing arthroplasty, and to use these results to compare the posterior and the trochanteric-flip approaches. Methods: In our previous work, we reported changes to intra-operative blood flow during hip resurfacing arthroplasty comparing two surgical approaches. In this study, we report the vascularity and the metabolic bone function in the proximal femur in these same patients at one year after the surgery. Vascularity and bone function was assessed using scintigraphic techniques. Of the 13 patients who agreed to take part, eight had their arthroplasty through a posterior approach and five through a trochanteric-flip approach. Results: One year after surgery, we found no difference in the vascularity (vascular phase) and metabolic bone function (delayed phase) at the junction of the femoral head/neck between the two groups of patients. Higher radiopharmaceutical uptake was found in the region of the greater trochanter in the trochanteric-flip group, related to the healing osteotomy. Conclusions: Our findings using scintigraphic techniques suggest that the greater intra-operative reduction in blood flow to the junction of the femoral head/neck, which is seen with the posterior approach compared with trochanteric flip, does not result in any difference in vascularity or metabolic bone function one year after surgery

    Inferior outcome after hip resurfacing arthroplasty than after conventional arthroplasty: Evidence from the Nordic Arthroplasty Register Association (NARA) database, 1995 to 2007

    Get PDF
    Today, total hip arthroplasty (THA) is one of the safest and most efficient surgical treatments. New materials, surgical techniques and design concepts intended to improve THA have not always been successful. Thorough preclinical and early clinical investigations can detect some aspects of under-performing, while continuing surveillance is recommended to detect and analyze reasons for any later appearing flaws. In this thesis, several ways to monitor and assess THA performance are explored and carried out, using survival analysis in registry studies, radiostereometry (RSA), radiology and clinical outcome. In Paper I, a study using the Nordic Arthroplasty Register Association (NARA) registry shows that HRA had an almost 3-fold increased early non-septic revision risk and that risk factors were found to be female sex, certain HRA designs and units having performed few HRA procedures. Papers II and III contain comparisons of highly cross-linked polyethylene (XLPE) and conventional polyethylene (PE). XLPE had a considerably lower wear rate up to 10 years but showed no obvious improvements regarding implant fixation, BMD or clinical outcome. In the NARA registry, in 2 of 4 studied cup designs the XLPE version had a lower risk of revision for aseptic loosening compared to the PE version. Paper IV describes that stem subsidence and retrotorsion measured with RSA at 2 years predicted later aseptic stem failure in an unfavorably altered, previously well-functioning cemented femoral stem. In Paper V and VI, a novel approach to measure articulation wear with RSA in radiodense hip arthroplasty articulations was presented and evaluated. Subsequently, a comparison between ceramic-on-ceramic (COC) and metal-on-conventional PE uncemented THA displayed a considerably lower wear rate, smaller periacetabular bone lesions and a relatively high squeaking rate, the latter with unknown long-term consequences, in the COC hips. Implant fixation, heterotopic ossification and clinical outcome did not differ between articulation types. In conclusion, it was confirmed that implant surveillance can be done with RSA, also in radiodense THA. Early migration predicts later aseptic implant failure. Prolonged surveillance can confirm long-term material and design performance, verify or contradict anticipated advantages as well as detect unanticipated long-term complications

    Femoroacetabular impingement: normal values of the quantitative morphometric parameters in asymptomatic hips.

    Get PDF
    OBJECTIVE: To determine the means and the reference intervals of the quantitative morphometric parameters of femoroacetabular impingement (FAI) in normal hips with high-resolution computed tomography (CT). METHODS: We prospectively included 94 adult individuals who underwent CT for thoracic, abdominal or urologic pathologies. Patients with a clinical history of hip pathology and/or with osteoarthritis on CT were excluded. We calculated means and 95 % reference intervals for imaging signs of cam-type (alpha angle at 90° and 45° and femoral head-neck offset) and pincer-type impingement (acetabular version angle, lateral centre-edge angle and acetabular index). RESULTS: The 95 % reference interval limits were all far beyond the abnormal thresholds found in the literature for cam-type and to a lesser extent for pincer-type FAI. The upper limits of the reference intervals for the alpha angles (at 90°/45°) were 68°/83° (men) and 69°/84° (women), compared to thresholds from the literature (50°, 55° or 60°). Reference intervals were similar between genders for cam-type parameters, and slightly differed for pincer-type. CONCLUSION: The 95 % reference intervals of morphometric measurements of FAI in asymptomatic hips were beyond the abnormal thresholds, which was especially true for cam-type FAI. Our results suggest the need for redefining the current morphometric parameters used in the diagnosis of FAI. KEY POINTS: ? 95 % reference intervals limits of FAI morphotype were beyond currently defined thresholds. ? Reference intervals of pincer-type morphotype measurements were close to current definitions. ? Reference intervals of cam-type morphotype measurements were far beyond the current definitions. ? Current morphometric definitions of cam-type morphotype should be used with care

    Defining modes of failure after joint-preserving surgery of the hip

    No full text

    The terminal branches of the medial femoral circumflex artery

    No full text
    corecore