22 research outputs found

    Sampling considerations and assessment of Exetainer usage for measuring dissolved and gaseous methane and nitrous oxide in aquatic systems

    Get PDF
    Pre-evacuated Exetainers are commonly used as measurement vials for the determination of methane (CH4) and nitrous oxide (N2O) concentrations in liquid and gaseous samples from aquatic environments. The impact of residual air in these Exetainers on measurement accuracy is assessed. Residual air pressure in commercially available, pre-evacuated Exetainers varied between 0.071 +/- 0.008 atm and 0.180 +/- 0.031 atm in examined batches. This background contamination can lead to large errors when determining dissolved and gaseous CH4 and N2O concentrations particularly at low concentrations. A method for Exetainer pretreatment is suggested and verified, to reduce the residual CH4 and N2O. Vials are flushed (needle 30 G 3 0.5 '', 0.3 mm) with nitrogen gas (N-2) for 5 min, which reduces the background CH4 and N2O concentrations to 0.092 +/- 0.008 ppm and 0.016 +/- 0.001 ppm, respectively, approximately 3-4% of their respective concentrations in air. To avoid an alteration of sample concentration by variable residual gas levels left during a pre-evacuation step, liquid and gaseous samples are injected into the N-2 filled Exetainers. For gaseous samples where large volumes of gas are available, Exetainers can alternatively be flushed with 100 mL of sampling gas. For gaseous samples, measured CH4 and N2O concentrations of standard gases were statistically identical to their known concentrations. For liquid samples, measured CH4 and N2O concentrations of liquid standard dilution series showed strong linear correlations with theoretically calculated concentrations (slope CH4: 1.04, slope N2O: 1.12). Sample concentrations remained constant over a minimum storage period of 6 weeks

    Swiss Survey on current practices and opinions on clinical constellations triggering the search for PNH clones.

    Get PDF
    UNLABELLED This national survey investigated the current practice in Switzerland by collecting participants' opinions on paroxysmal nocturnal hemoglobinuria (PNH) clone assessment and clinical practice. AIM This study aimed to investigate clinical indications prompting PNH clones' assessment and physician's accessibility of a flow cytometry facility, and also to understand clinical attitudes on the follow-up (FU) of patients with PNH clones. METHODS The survey includes 16 multiple-choice questions related to PNH and targets physicians with a definite level of experience in the topic using two screener questions. Opinion on clinical management was collected using hypothetical clinical situations. Each participant had the option of being contacted to further discuss the survey results. This was an online survey, and 264 physicians were contacted through email once a week for 5 weeks from September 2020. RESULTS In total, 64 physicians (24.2%) from 23 institutions participated (81.3% hematologists and 67.2% from university hospitals). All had access to flow cytometry for PNH clone testing, with 76.6% having access within their own institution. The main reasons to assess for PNH clones were unexplained thrombosis and/or hemolysis, and/or aplastic anemia (AA). Patients in FU for PNH clones were more likely to be aplastic anemia (AA) and symptomatic PNH. In total, 61% of the participants investigated PNH clones repetitively during FU in AA/myelodysplastic syndromes patients, even when there was no PNH clone found at diagnosis, and 75% of the participants tested at least once a year during FU. Opinions related to clinical management were scattered. CONCLUSION The need to adhere to guidelines for the assessment, interpretation, and reporting of PNH clones emerges as the most important finding, as well as consensus for the management of less well-defined clinical situations. Even though there are several international guidelines, clear information addressing specific topics such as the type of anticoagulant to use and its duration, as well as the indication for treatment with complement inhibitors in some borderline situations are needed. The analysis and the discussion of this survey provide the basis for understanding the unmet needs of PNH clone assessment and clinical practice in Switzerland

    An efficient method for measuring dissolved VOSCs in wastewater using GC-SCD with static headspace technique

    Get PDF
    Volatile organic sulfur compounds (VOSCs) are important sources of unpleasant odor in wastewater systems. However, the study of VOSCs is usually hindered by their complicated measurement method and highly reactive nature. In this work, a static headspace method utilising gas chromatography (GC) with a sulfur chemiluminescence detector (SCD) was developed to quantitatively analyze VOSCs in wastewater matrices. The method has low detection limits and requires no pre-concentration treatment. Three typical VOSCs, namely methanethiol (MT), dimethyl sulfide (DMS) and dimethyl disulfide (DMDS), were chosen as examples for this study. The calibration curves of all three compounds covering a wide range from 0.5 ppb to 500 ppb showed good linearity (R-2 > 0.999). The method detection limits (MDL) were 0.08, 0.12 and 0.21 ppb for MT, DMS and DMDS, respectively. The reproducibility (relative standard deviation) was approximately 2%. The recovery ratio of MT, DMS and DMDS in spiked wastewater samples were 83 +/- 4%, 103 +/- 4% and 102 +/- 3%, respectively. Sample preservation tests showed that VOSCs in wastewater samples could be preserved in vials without headspace under acidified conditions (pH similar to 1.1) for at least 24 h without significant changes

    Search for single production of vector-like quarks decaying into Wb in pp collisions at s=8\sqrt{s} = 8 TeV with the ATLAS detector

    Get PDF

    Measurement of the charge asymmetry in top-quark pair production in the lepton-plus-jets final state in pp collision data at s=8TeV\sqrt{s}=8\,\mathrm TeV{} with the ATLAS detector

    Get PDF

    Measurement of the bbb\overline{b} dijet cross section in pp collisions at s=7\sqrt{s} = 7 TeV with the ATLAS detector

    Get PDF

    ATLAS Run 1 searches for direct pair production of third-generation squarks at the Large Hadron Collider

    Get PDF

    Charged-particle distributions at low transverse momentum in s=13\sqrt{s} = 13 TeV pppp interactions measured with the ATLAS detector at the LHC

    Get PDF

    Search for dark matter in association with a Higgs boson decaying to bb-quarks in pppp collisions at s=13\sqrt s=13 TeV with the ATLAS detector

    Get PDF

    Optimization of integrated chemical-biological degradation of a reactive azo dye using response surface methodology

    No full text
    The integrated chemical-biological degradation combining advanced oxidation by UV/H2O2 followed by aerobic biodegradation was used to degrade C.I. Reactive Azo Red 195A, commonly used in the textile industry in Australia. An experimental design based on the response surface method was applied to evaluate the interactive effects of influencing factors (UV irradiation time, initial hydrogen peroxide dosage and recirculation ratio of the system) on decolourisation efficiency and optimizing the operating conditions of the treatment process. The effects were determined by the measurement of dye concentration and soluble chemical oxygen demand (S-COD). The results showed that the dye and S-COD removal were affected by all factors individually and interactively. Maximal colour degradation performance was predicted, and experimentally validated, with no recirculation, 30 min UV irradiation and 500 mg H2O2/L. The model predictions for colour removal, based on a three-factor/five-level Box-Wilson central composite design and the response surface method analysis, were found to be very close to additional experimental results obtained under near optimal conditions. This demonstrates the benefits of this approach in achieving good predictions while minimising the number of experiments required. (c) 2006 Elsevier B.V. All rights reserved
    corecore