8 research outputs found

    Transcatheter interatrial shunt device for the treatment of heart failure with preserved ejection fraction (REDUCE LAP-HF I [Reduce Elevated Left Atrial Pressure in Patients With Heart Failure]): A phase 2, randomized, sham-controlled trial

    Get PDF
    Background -In non-randomized, open-label studies, a transcatheter interatrial shunt device (IASD, Corvia Medical) was associated with lower pulmonary capillary wedge pressure (PCWP), less symptoms, and greater quality of life and exercise capacity in patients with heart failure (HF) and mid-range or preserved ejection fraction (EF ≥ 40%). We conducted the first randomized, sham-controlled trial to evaluate the IASD in HF with EF ≥ 40%. Methods -REDUCE LAP-HF I was a phase 2, randomized, parallel-group, blinded multicenter trial in patients with New York Heart Association (NYHA) class III or ambulatory class IV HF, EF ≥ 40%, exercise PCWP ≥ 25 mmHg, and PCWP-right atrial pressure gradient ≥ 5 mmHg. Participants were randomized (1:1) to the IASD vs. a sham procedure (femoral venous access with intracardiac echocardiography but no IASD placement). The participants and investigators assessing the participants during follow-up were blinded to treatment assignment. The primary effectiveness endpoint was exercise PCWP at 1 month. The primary safety endpoint was major adverse cardiac, cerebrovascular, and renal events (MACCRE) at 1 month. PCWP during exercise was compared between treatment groups using a mixed effects repeated measures model analysis of covariance that included data from all available stages of exercise. Results -A total of 94 patients were enrolled, of which n=44 met inclusion/exclusion criteria and were randomized to the IASD (n=22) and control (n=22) groups. Mean age was 70±9 years and 50% were female. At 1 month, the IASD resulted in a greater reduction in PCWP compared to sham-control (P=0.028 accounting for all stages of exercise). Peak PCWP decreased by 3.5±6.4 mmHg in the treatment group vs. 0.5±5.0 mmHg in the control group (P=0.14). There were no peri-procedural or 1-month MACCRE in the IASD group and 1 event (worsening renal function) in the control group (P=1.0). Conclusions -In patients with HF and EF ≥ 40%, IASD treatment reduces PCWP during exercise. Whether this mechanistic effect will translate into sustained improvements in symptoms and outcomes requires further evaluation. Clinical Trial Registration -URL: http://clinicaltrials.gov. Unique identifier: NCT02600234

    One-year safety and clinical outcomes of a transcatheter interatrial shunt device for the treatment of heart failure with preserved ejection fraction in the reduce elevated left atrial pressure in patients with heart failure (REDUCE LAP-HF I) trial: a randomized clinical trial

    No full text
    Importance In patients with heart failure (HF) and left ventricular ejection fraction (LVEF) equal to or greater than 40%, a transcatheter interatrial shunt device (IASD; Corvia Medical) reduces exercise pulmonary capillary wedge pressure (PCWP) and is safe compared with sham control treatment at 1 month of follow-up. The longer-term safety and patency of the IASD has not yet been demonstrated in the setting of a randomized clinical trial (RCT). Objective: To evaluate the 1-year safety and clinical outcomes of the IASD compared with a sham control treatment. Design, Setting, and Participants: This phase 2, double-blind, 1-to-1 sham-controlled multicenter RCT of IASD implantation vs a sham procedure (femoral venous access and imaging of the interatrial septum without IASD) was conducted in 22 centers in the United States, Europe, and Australia on patients with New York Heart Association (NYHA) class III or ambulatory class IV HF, LVEF equal to or greater than 40%, exercise PCWP equal to or greater than 25 mm Hg, and PCWP-right atrial pressure gradient equal to or greater than 5 mm Hg. Main Outcomes and Measures: Safety was assessed by major adverse cardiac, cerebrovascular, or renal events (MACCRE). Exploratory outcomes evaluated at 1 year were hospitalizations for HF, NYHA class, quality of life, a 6-minute walk test, and device patency. Results: After 1 year, shunts were patent in all IASD-treated patients; MACCRE did not differ significantly in the IASD arm (2 of 21 [9.5%]) vs the control arm (5 of 22 [22.7%]; P = .41), and no strokes occurred. The yearly rate of hospitalizations for HF was 0.22 in the IASD arm and 0.63 in the control arm (P = .06). Median improvement in NYHA class was 1 class in the IASD arm (IQR, −1 to 0) vs 0 in the control arm (IQR, −1 to 0; P = .08). Quality of life and 6-minute walk test distance were similar in both groups. At 6 months, there was an increase in right ventricular size in the IASD arm (mean [SD], 7.9 [8.0] mL/m2) vs the control arm (−1.8 [9.6] mL/m2; P = .002), consistent with left-to-right shunting through the device; no further increase occurred in the IASD arm at 12 months. Conclusions and Relevance: The REDUCE LAP-HF I phase 2, sham-controlled RCT confirms the longer-term patency of the IASD. Through 1 year of follow-up, IASD treatment appears safe, with no significant differences in MACCRE in patients receiving IASD compared with those who received sham control treatment. Trial Registration: ClinicalTrials.gov identifier: NCT0260023
    corecore