1,615 research outputs found

    The Hubble Constant

    Full text link
    Considerable progress has been made in determining the Hubble constant over the past two decades. We discuss the cosmological context and importance of an accurate measurement of the Hubble constant, and focus on six high-precision distance-determination methods: Cepheids, tip of the red giant branch, maser galaxies, surface brightness fluctuations, the Tully-Fisher relation and Type Ia supernovae. We discuss in detail known systematic errors in the measurement of galaxy distances and how to minimize them. Our best current estimate of the Hubble constant is 73 +/-2 (random) +/-4 (systematic) km/s/Mpc. The importance of improved accuracy in the Hubble constant will increase over the next decade with new missions and experiments designed to increase the precision in other cosmological parameters. We outline the steps that will be required to deliver a value of the Hubble constant to 2% systematic uncertainty and discuss the constraints on other cosmological parameters that will then be possible with such accuracy.Comment: To be published in Annual Reviews of Astronomy and Astrophysics, Vol. 48, 2010, consisting of 79 pages, 13 figures, 2 table

    Low Mate Encounter Rate Increases Male Risk Taking in a Sexually Cannibalistic Praying Mantis

    Get PDF
    Male praying mantises are forced into the ultimate trade-off of mating versus complete loss of future reproduction if they fall prey to a female. The balance of this trade-off will depend both on (1) the level of predatory risk imposed by females and (2) the frequency of mating opportunities for males. We report the results of a set of experiments that examine the effects of these two variables on male risk-taking behavior and the frequency of sexual cannibalism in the praying mantis Tenodera sinensis. We experimentally altered the rate at which males encountered females and measured male approach and courtship behavior under conditions of high and low risk of being attacked by females. We show that male risk taking depends on prior access to females. Males with restricted access to females showed greater risk-taking behavior. When males were given daily female encounters, they responded to greater female-imposed risk by slowing their rate of approach and remained a greater distance from a potential mate. In contrast, males without recent access to mates were greater risk-takers; they approached females more rapidly and to closer proximity, regardless of risk. In a second experiment, we altered male encounter rate with females and measured rates of sexual cannibalism when paired with hungry or well-fed females. Greater risk-taking behavior by males with low mate encounter rates resulted in high rates of sexual cannibalism when these males were paired with hungry females

    Management of pediatric radiation dose using GE fluoroscopic equipment

    Get PDF
    In this article, we present GE Healthcare’s design philosophy and implementation of X-ray imaging systems with dose management for pediatric patients, as embodied in its current radiography and fluoroscopy and interventional cardiovascular X-ray product offerings. First, we present a basic framework of image quality and dose in the context of a cost–benefit trade-off, with the development of the concept of imaging dose efficiency. A set of key metrics of image quality and dose efficiency is presented, including X-ray source efficiency, detector quantum efficiency (DQE), detector dynamic range, and temporal response, with an explanation of the clinical relevance of each. Second, we present design methods for automatically selecting optimal X-ray technique parameters (kVp, mA, pulse width, and spectral filtration) in real time for various clinical applications. These methods are based on an optimization scheme where patient skin dose is minimized for a target desired image contrast-to-noise ratio. Operator display of skin dose and Dose-Area Product (DAP) is covered, as well. Third, system controls and predefined protocols available to the operator are explained in the context of dose management and the need to meet varying clinical procedure imaging demands. For example, fluoroscopic dose rate is adjustable over a range of 20:1 to adapt to different procedure requirements. Fourth, we discuss the impact of image processing techniques upon dose minimization. In particular, two such techniques, dynamic range compression through adaptive multiband spectral filtering and fluoroscopic noise reduction, are explored in some detail. Fifth, we review a list of system dose-reduction features, including automatic spectral filtration, virtual collimation, variable-rate pulsed fluoroscopic, grid and no-grid techniques, and fluoroscopic loop replay with store. In addition, we describe a new feature that automatically minimizes the patient-to-detector distance, along with an estimate of its dose reduction potential. Finally, two recently developed imaging techniques and their potential effect on dose utilization are discussed. Specifically, we discuss the dose benefits of rotational angiography and low frame rate imaging with advanced image processing in lieu of higher-dose digital subtraction

    Oncolysis of malignant human melanoma tumors by Coxsackieviruses A13, A15 and A18

    Get PDF
    Many RNA viruses are displaying great promise in the field of oncolytic virotherapy. Previously, we reported that the picornavirus Coxsackievirus A21 (CVA21) possessed potent oncolytic activity against cultured malignant melanoma cells and melanoma xenografts in mice. In the present study, we demonstrate that three additional Group A Coxsackieviruses; Coxsackievirus A13 (CVA13), Coxsackievirus A15 (CVA15) and Coxsackievirus A18 (CVA18), also have similar oncolytic activity against malignant melanoma. Each of the viruses grew quickly to high titers in cancer cells expressing ICAM-1 and intratumoral injection of preformed subcutaneous SK-Mel-28 xenografts in mice with CVA13, CVA15 and CVA18 resulted in significant tumor volume reduction

    Potential of a cyclone prototype spacer to improve in vitro dry powder delivery

    Get PDF
    Copyright The Author(s) 2013. This article is published with open access at Springerlink.com. This article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are creditedPurpose: Low inspiratory force in patients with lung disease is associated with poor deagglomeration and high throat deposition when using dry powder inhalers (DPIs). The potential of two reverse flow cyclone prototypes as spacers for commercial carrierbased DPIs was investigated. Methods: Cyclohaler®, Accuhaler® and Easyhaler® were tested with and without the spacers between 30-60 Lmin-1. Deposition of particles in the next generation impactor and within the devices was determined by high performance liquid chromatography. Results: Reduced induction port deposition of the emitted particles from the cyclones was observed due to the high retention of the drug within the spacers (e.g. salbutamol sulphate (SS): 67.89 ± 6.51 % at 30 Lmin-1 in Cheng 1). Fine particle fractions of aerosol as emitted from the cyclones were substantially higher than the DPIs alone. Moreover, the aerodynamic diameters of particles emitted from the cyclones were halved compared to the DPIs alone (e.g. SS from the Cyclohaler® at 4 kPa: 1.08 ± 0.05 μm vs. 3.00 ± 0.12 μm, with and without Cheng 2, respectively) and unaltered with increased flow rates. Conclusion: This work has shown the potential of employing a cyclone spacer for commercial carrier-based DPIs to improve inhaled drug delivery.Peer reviewe

    Incommensurable worldviews? Is public use of complementary and alternative medicines incompatible with support for science and conventional medicine?

    Get PDF
    Proponents of controversial Complementary and Alternative Medicines, such as homeopathy, argue that these treatments can be used with great effect in addition to, and sometimes instead of, ?conventional? medicine. In doing so, they accept the idea that the scientific approach to the evaluation of treatment does not undermine use of and support for some of the more controversial CAM treatments. For those adhering to the scientific canon, however, such efficacy claims lack the requisite evidential basis from randomised controlled trials. It is not clear, however, whether such opposition characterises the views of the general public. In this paper we use data from the 2009 Wellcome Monitor survey to investigate public use of and beliefs about the efficacy of a prominent and controversial CAM within the United Kingdom, homeopathy. We proceed by using Latent Class Analysis to assess whether it is possible to identify a sub-group of the population who are at ease in combining support for science and conventional medicine with use of CAM treatments, and belief in the efficacy of homeopathy. Our results suggest that over 40% of the British public maintain positive evaluations of both homeopathy and conventional medicine simultaneously. Explanatory analyses reveal that simultaneous support for a controversial CAM treatment and conventional medicine is, in part, explained by a lack of scientific knowledge as well as concerns about the regulation of medical research

    The antimicrobial polymer PHMB enters cells and selectively condenses bacterial chromosomes

    Get PDF
    To combat infection and antimicrobial resistance, it is helpful to elucidate drug mechanism(s) of action. Here we examined how the widely used antimicrobial polyhexamethylene biguanide (PHMB) kills bacteria selectively over host cells. Contrary to the accepted model of microbial membrane disruption by PHMB, we observed cell entry into a range of bacterial species, and treated bacteria displayed cell division arrest and chromosome condensation, suggesting DNA binding as an alternative antimicrobial mechanism. A DNA-level mechanism was confirmed by observations that PHMB formed nanoparticles when mixed with isolated bacterial chromosomal DNA and its effects on growth were suppressed by pairwise combination with the DNA binding ligand Hoechst 33258. PHMB also entered mammalian cells, but was trapped within endosomes and excluded from nuclei. Therefore, PHMB displays differential access to bacterial and mammalian cellular DNA and selectively binds and condenses bacterial chromosomes. Because acquired resistance to PHMB has not been reported, selective chromosome condensation provides an unanticipated paradigm for antimicrobial action that may not succumb to resistance
    • …
    corecore