4,633 research outputs found

    Investigation of charge sharing among electrode strips for a CdZnTe detector

    Get PDF
    We have investigated charge sharing among the anode strips of a CdZnTe (CZT) detector using a 30 micrometer collimated gamma-ray beam. We compared the laboratory measurements with the predictions from our modeling of the charge transport within the detector. The results indicate that charge sharing is a function of the interaction depth and the energy of the incoming photon. Also, depending on depth, a fraction of the electrons might drift to the inter-anode region causing incomplete charge collection. Here, we show that photoelectron range and diffusion of the charge cloud are the principal causes of charge sharing and obtain limits on the size of the electron cloud as a function of position in the detector.Comment: 16 pages 10 figures. Accepted for publication in Nuclear Instruments and Methods -

    Simultaneous BeppoSAX and RXTE observations of the X-ray burst sources GX 3+1 and Ser X-1

    Get PDF
    We have obtained spectral and timing data on GX 3+1 and Ser X-1. Both sources were observed simultaneously with BeppoSAX and RXTE. The RXTE data is used to provide power spectra and colour-colour diagrams in order to constrain the state (and thus track M˙\dot M) the sources are in. The BeppoSAX data provide the broad-band spectra. The spectra of both sources are reasonably well-fit using a model consisting of a disk-blackbody, a comptonized component and a Fe line, absorbed by interstellar absorption. The electron temperature (kTe_{\rm e}) of the Comptonizing plasma is in both cases ∼\sim2.5 keV. This implies that no strong high-energy tail from the Comptonized component is present in either of the sources. We discuss the similarities between these burst sources and the luminous X-ray sources located in globular clusters. We find that the spectral parameters of the comptonized component provide information about the mass-accretion rate, which agrees well with estimates from the timing and spectral variations.Comment: 8 pages, accepted by A&

    Constraining the equation of state of supra-nuclear dense matter from XMM-Newton observations of neutron stars in globular clusters

    Full text link
    We report on the detailed modelling of the X-ray spectra of three likely neutron stars. The neutron stars, observed with XMM-Newton are found in three quiescent X-ray binaries in the globular clusters: omega Cen, M 13 and NGC 2808. Whether they are accreting at very low rates or radiating energy from an accretion heated core, their X-ray spectra are expected to be those of a hydrogen atmosphere. We use and compare publicly available hydrogen atmosphere models, with constant and varying surface gravities to constrain the masses and radii of the neutron stars. Thanks to the high XMM-Newton throughput, and the accurate distances available for these clusters, using the latest science analysis software release and calibration of the XMM-Newton EPIC cameras, we derive the most stringent constraints on the masses and radii of the neutron stars obtained to date from these systems. A comparison of the models indicate that previously used hydrogen atmosphere models (assuming constant surface gravity) tend to underestimate the mass and overestimate the radius of neutron stars. Our data constrain the allowed equations of state to those which concern normal nucleonic matter and one possible strange quark matter model, thus constraining radii to be from 8 km and masses up to 2.4 M⊙_\odot.Comment: 10 pages, 8 figures, accepted to be published in The Astrophysical Journa

    Ground-based FTIR measurements of CO from the Jungfraujoch: characterisation and comparison with <i>in situ</i> surface andMOPITT data

    No full text
    International audienceCO vertical profiles have been retrieved from solar absorption FTIR spectra recorded at the NDSC station of the Jungfraujoch (46.5° N, 8° E and 3580 m a.s.l.) for the period from January 1997 to May 2001. The characterisation of these profiles has been established by an information content analysis and an estimation of the error budgets. A partial validation of the profiles has been performed through comparisons with correlative measurements. The average volume mixing ratios (vmr) in the 3 km layer above the station have been compared with coincident surface measurements. The agreement between monthly means from both measurement techniques is very good, with a correlation coefficient of 0.87, and no significant bias observed. The FTIR total columns have also been compared to CO partial columns above 3580 m a.s.l. derived from the MOPITT (Measurement Of Pollution In The Troposphere) instrument for the period March 2000 to May 2001. Relative to the FTIR columns, the MOPITT partial columns exhibit a positive bias of 8±8% for daytime and of 4±7% for nighttime measurements

    Update on the ICUD-SIU consultation on multi-parametric magnetic resonance imaging in localised prostate cancer

    Get PDF
    Introduction: Prostate cancer (PCa) imaging is a rapidly evolving field. Dramatic improvements in prostate MRI during the last decade will probably change the accuracy of diagnosis. This chapter reviews recent current evidence about MRI diagnostic performance and impact on PCa management. Materials and methods: The International Consultation on Urological Diseases nominated a committee to review the literature on prostate MRI. A search of the PubMed database was conducted to identify articles focussed on MP-MRI detection and staging protocols, reporting and scoring systems, the role of MP-MRI in diagnosing PCa prior to biopsy, in active surveillance, in focal therapy and in detecting local recurrence after treatment. Results: Differences in opinion were reported in the use of the strength of magnets [1.5 Tesla (T) vs. 3T] and coils. More agreement was found regarding the choice of pulse sequences; diffusion-weighted MRI (DW-MRI), dynamic contrast-enhanced MRI (DCE MRI), and/or MR spectroscopy imaging (MRSI) are recommended in addition to conventional T2-weighted anatomical sequences. In 2015, the Prostate Imaging Reporting and Data System (PI-RADS version 2) was described to standardize image acquisition and interpretation. MP-MRI improves detection of clinically significant PCa (csPCa) in the repeat biopsy setting or before the confirmatory biopsy in patients considering active surveillance. It is useful to guide focal treatment and to detect local recurrences after treatment. Its role in biopsy-naive patients or during the course of active surveillance remains debated. Conclusion: MP-MRI is increasingly used to improve detection of csPCa and for the selection of a suitable therapeutic approach
    • …
    corecore