13 research outputs found

    Sensitivity analysis of Monte Carlo model of a gantry-mounted passively scattered proton system

    Get PDF
    PURPOSE: This study aimed to present guidance on the correlation between treatment nozzle and proton source parameters, and dose distribution of a passive double scattering compact proton therapy unit, known as Mevion S250. METHODS: All 24 beam options were modeled using the MCNPX MC code. The calculated physical dose for pristine peak, profiles, and spread out Bragg peak (SOBP) were benchmarked with the measured data. Track-averaged LET (LET RESULTS: For the physical dose distribution, the MCNPX MC model matched measurements data for all the options to within 2 mm and 2% criterion. The Mevion S250 was found to have a LET CONCLUSIONS: This study revealed the importance of considering detailed beam parameters, and identifying those that resulted in large effects on the physical dose distribution and LETs for a compact proton therapy machine

    Dosimetric impact of range uncertainty in passive scattering proton therapy

    Get PDF
    PURPOSE: The objective of this study was to investigate the dosimetric impact of range uncertainty in a large cohort of patients receiving passive scatter proton therapy. METHODS: A cohort of 120 patients were reviewed in this study retrospectively, of which 61 were brain, 39 lung, and 20 prostate patients. Range uncertainties of ±3.5% (overshooting and undershooting by 3.5%, respectively) were added and recalculated on the original plans, which had been planned according to our clinical planning protocol while keeping beamlines, apertures, compensators, and dose grids intact. Changes in the coverage on CTV and DVH for critical organs were compared and analyzed. Correlation between dose change and minimal distance between CTV and critical organs were also investigated. RESULTS: Although CTV coverages and maximum dose to critical organs were largely maintained for most brain patients, large variations over 5% were still observed sporadically. Critical organs, such as brainstem and chiasm, could still be affected by range uncertainty at 4 cm away from CTV. Coverage and OARs in lung and prostate patients were less likely to be affected by range uncertainty with very few exceptions. CONCLUSION: The margin recipe in modern TPS leads to clinically acceptable OAR doses in the presence of range uncertainties. However, range uncertainties still pose a noticeable challenge for small but critical serial organs near tumors, and occasionally for large parallel organs that are located distal to incident proton beams

    Remote global radiation oncology education and training: A pathway to increase access to high-quality radiation therapy services in low- and middle-income countries

    Get PDF
    PURPOSE: There is a vital need to train radiation therapy professionals in low- and middle-income countries (LMICs) to develop sustainable cancer treatment capacity and infrastructure. LMICs have started to introduce intensity modulated radiation therapy (IMRT), which is the standard of care in high-income countries, because of improved outcomes and reduced toxicities. This work reports the efficacy of a complementary asynchronous plus synchronous virtual-training approach on improving radiation therapy professions\u27 self-confidence levels and evaluating participants\u27 attitudes toward asynchronous and synchronous didactic hands-on learning in 3 LMICs. METHODS AND MATERIALS: Training was provided to 37 participants from Uganda, Guatemala, and Mongolia, which included 4 theoretical lectures, 4 hands-on sessions, and 8 self-guided online videos. The 36-day training focused on IMRT contouring, site-specific target/organ definition, planning/optimization, and quality assurance. Participants completed pre- and postsession confidence surveys on a 0 to 10 scale, which was converted to a 5-point Likert rating scale to evaluate the training outcomes. The pros and cons of the 3 different training formats were compared. RESULTS: The participants included 15 (40.5%) radiation oncologists, 11 (29.7%) medical physicists, 6 (16.2%) radiation therapists, and 5 (13.5%) dosimetrists. Approximately 50% had more than 10 years of radiation therapy experience, 70.8% had no formal IMRT training, and only 25% had IMRT at their institutions. The average experience and confidence levels in using IMRT at baseline were 3.2 and 2.9, which increased to 5.2 and 4.9 ( CONCLUSIONS: After completing the training sessions, Uganda and Mongolia started IMRT treatments. Remote training provides an excellent and feasible e-learning platform to train radiation therapy professionals in LMICs. The training program improved the IMRT confidence levels and treatment delivery. The hands-on trainings were most preferred

    Simulation-free radiation therapy: An emerging form of treatment planning to expedite plan generation for patients receiving palliative radiation therapy

    Get PDF
    PURPOSE: Herein we report the clinical and dosimetric experience for patients with metastases treated with palliative simulation-free radiation therapy (SFRT) at a single institution. METHODS AND MATERIALS: SFRT was performed at a single institution. Multiple fractionation regimens were used. Diagnostic imaging was used for treatment planning. Patient characteristics as well as planning and treatment time points were collected. A matched cohort of patients with conventional computed tomography simulation radiation therapy (CTRT) was acquired to evaluate for differences in planning and treatment time. SFRT dosimetry was evaluated to determine the fidelity of SFRT. Descriptive statistics were calculated on all variables and statistical significance was evaluated using the Wilcoxon signed rank test and RESULTS: Thirty sessions of SFRT were performed and matched with 30 sessions of CTRT. Seventy percent of SFRT and 63% of CTRT treatments were single fraction. The median time to plan generation was 0.88 days (0.19-1.47) for SFRT and 1.90 days (0.39-5.23) for CTRT ( CONCLUSIONS: Palliative SFRT is an emerging technique that allowed for a statistically significant lower time to plan generation and was dosimetrically acceptable. This benefit must be weighed against increased total treatment time for patients receiving SFRT compared with CTRT, and appropriate patient selection is critical

    Use of diverging apertures to minimize the edge scatter in passive scattering proton therapy

    Get PDF
    The purpose of this study was to evaluate the use of diverging-cut aperture to minimize collimator contamination in proton therapy. Two sets of apertures with nondivergent and divergent edge were fabricated to produce a 10 cm x 10 cm field at the radiation isocenter of a single-room proton therapy unit. Transverse profiles were acquired in a scanning water tank with both aperture sets. Up to 9.5% extra dose was observed from aperture scattering near the field edges with the nondivergent aperture set at 2 cm above the water surface and remained 3.0% at depth of 10 cm. For the divergent set, the contamination was reduced to less than 3.5% and 1.3%, respectively. Our study demonstrated that scattering from apertures contaminated the dose distribution near the field edge at shallow depth. A diverging-cut aperture was capable of reducing the contamination and is recommended for use in passive scattering proton therapy, especially when critical organs are lateral and proximal to the target at shallow depth

    Commissioning and initial experience with the first clinical gantry-mounted proton therapy system

    Get PDF
    The purpose of this study is to describe the comprehensive commissioning process and initial clinical experience of the Mevion S250 proton therapy system, a gantry-mounted, single-room proton therapy platform clinically implemented in the S. Lee Kling Proton Therapy Center at Barnes-Jewish Hospital in St. Louis, MO, USA. The Mevion S250 system integrates a compact synchrocyclotron with a C-inner gantry, an image guidance system and a 6D robotic couch into a beam delivery platform. We present our commissioning process and initial clinical experience, including i) CT calibration; ii) beam data acquisition and machine characteristics; iii) dosimetric commissioning of the treatment planning system; iv) validation through the Imaging and Radiation Oncology Core credentialing process, including irradiations on the spine, prostate, brain, and lung phantoms; v) evaluation of localization accuracy of the image guidance system; and vi) initial clinical experience. Clinically, the system operates well and has provided an excellent platform for the treatment of diseases with protons

    Rare Earth Ion-Doped Upconversion Nanocrystals: Synthesis and Surface Modification

    No full text
    The unique luminescent properties exhibited by rare earth ion-doped upconversion nanocrystals (UCNPs), such as long lifetime, narrow emission line, high color purity, and high resistance to photobleaching, have made them widely used in many areas, including but not limited to high-resolution displays, new-generation information technology, optical communication, bioimaging, and therapy. However, the inherent upconversion luminescent properties of UCNPs are influenced by various parameters, including the size, shape, crystal structure, and chemical composition of the UCNPs, and even the chosen synthesis process and the surfactant molecules used. This review will provide a complete summary on the synthesis methods and the surface modification strategies of UCNPs reported so far. Firstly, we summarize the synthesis methodologies developed in the past decades, such as thermal decomposition, thermal coprecipitation, hydro/solvothermal, sol-gel, combustion, and microwave synthesis. In the second part, five main streams of surface modification strategies for converting hydrophobic UCNPs into hydrophilic ones are elaborated. Finally, we consider the likely directions of the future development and challenges of the synthesis and surface modification, such as the large-scale production and actual applications, stability, and so on, of the UCNPs
    corecore