27 research outputs found

    Urinary Tract Fistulas: Transrenal Reversible Ureteral Occlusion With Detachable Semicompliant Balloons

    No full text
    OBJECTIVE To evaluate transrenal reversible ureteral occlusion with detachable balloons in patients with treatment-refractory urinary tract fistulas. METHODS From September 2009 to September 2013, reversible occlusion of 18 ureters (7 men, 3 women; 27-74 years) with treatment-refractory urinary leakage mostly because of tumor disease or iatrogenic surgical injury was performed. Nephrostomy was exchanged fluoroscopically into an 8F or 9F sheath, which was introduced into the ureter to the point of intended balloon inflation. The prepared semicompliant balloon on a special microcatheter was introduced into the sheath, inflated, and detached. A nephrostomy tube was placed in the pelvicalyceal system. After healing of the fistulas, urinary flow was restored by transureteral removal or computed tomography-guided percutaneous puncture of the balloons. RESULTS Hundred percent successful placement of the balloons and initial urinary fistula occlusion was achieved (18 of 18 ureters). One patient was lost during follow-up. Six of the remaining 9 patients needed reocclusion because of balloon dislocation or deflation (secondary technical success 83%; 5 of 6 ureters). A z-shaped ureter made reocclusion unsuccessful. Mean duration of ureteral occlusion was 74 days (5-250 days). After healing of the fistulas, intentional ureteral recanalization by percutaneous puncture or transureteral balloon removal was feasible. Anterograde urination was achieved in 5 of 9 patients (clinical success rate 55%). Four fistulas did not heal. Two patients died from their underlying disease. CONCLUSION Transrenal reversible off-label ureteral occlusion with semicompliant detachable balloons is feasible with a high technical success rate. Long-term ureteral occlusion can be achieved in nearly all patients with a moderate clinical success rate in heavily diseased patients. (C) 2015 Elsevier Inc

    Massive Air Embolism After Lung Biopsy

    No full text

    Incidental Findings in Abdominal Dual-Energy Computed Tomography: Correlation Between True Noncontrast and Virtual Noncontrast Images Considering Renal and Liver Cysts and Adrenal Masses

    No full text
    Purpose: To assess correlation between attenuation measurements of incidental findings in abdominal second generation dual-energy computed tomography (CT) on true noncontrast (TNC) and virtual noncontrast (VNC) images. Materials and Methods: Sixty-three patients underwent arterial dual-energy CT (Somatom Definition Flash, Siemens; pitch factor, 0.75-1.0; gantry rotation time, 0.28 seconds) after endovascular aneurysm repair, consisting of a TNC single energy CT scan (collimation, 128 x 0.6 mm; 120 kVp) and a dual-energy arterial phase scan (collimation, 32 x 0.6 mm, 140 and 100 kVp; blended, 120 kVp data set). Attenuation measurements in Hounsfield units (HU) of liver parenchyma and incidental findings like renal and hepatic cysts and adrenal masses on TNC and VNC images were done by drawing regions of interest. Statistical analysis was performed by paired t test and Pearson correlation. Results: Incidental findings were detected in 56 (89%) patients. There was excellent correlation for both renal (n = 40) and hepatic cysts (n = 12) as well as adrenal masses (n = 6) with a Pearson correlation of 0.896, 0.800, and 0.945, respectively, and mean attenuation values on TNC and VNC images of 10.6 HU +/- 12.8 versus 5.1 HU +/- 17.5 (attenuation value range from -8.8 to 59.1 HU vs -11.8 to 73.4 HU), 6.4 HU +/- 5.8 versus 6.3 HU +/- 4.6 (attenuation value range from 2.0 to 16.2 HU vs -3.0 to 15.9 HU), and 12.8 HU +/- 11.2 versus 12.4 HU +/- 10.2 (attenuation value range from -2.3 to 27.5 HU vs -2.2 to 23.6 HU), respectively. As proof of principle, liver parenchyma measurements also showed excellent correlation between TNC and VNC (n = 40) images with a Pearson correlation of 0.839 and mean attenuation values on TNC and VNC images of 47.2 HU +/- 10.5 versus 43.8 HU +/- 8.7 (attenuation value range from 21.9 to 60.2 HU vs 4.5 to 65.3 HU). Conclusions: In conclusion, attenuation measurements of incidental findings like renal cysts or adrenal masses on TNC and VNC images derived from second generation dual-energy CT scans show excellent correlation providing considerable dose savings, favorable for future application in clinical routine
    corecore