Comparison of wavelength selection methods for in-vitro estimation of lactate: a new unconstrained, genetic algorithm-based wavelength selection
Biochemical and medical literature establish lactate as a fundamental biomarker that can shed light on the energy consumption dynamics of the body at cellular and physiological levels. It is therefore, not surprising that it has been linked to many critical conditions ranging from the morbidity and mortality of critically ill patients to the diagnosis and prognosis of acute ischemic stroke, septic shock, lung injuries, insulin resistance in diabetic patients, and cancer. Currently, the gold standard for the measurement of lactate requires blood sampling. The invasive and costly nature of this procedure severely limits its application outside intensive care units. Optical sensors can provide a non-invasive, inexpensive, easy-to-use, continuous alternative to blood sampling. Previous efforts to achieve this have shown significant potential, but have been inconclusive. A measure that has been previously overlooked in this context, is the use of variable selection methods to identify regions of the optical spectrum that are most sensitive to and representative of the concentration of lactate. In this study, several wavelength selection methods are investigated and a new genetic algorithm-based wavelength selection method is proposed. This study shows that the development of more accurate and parsimonious models for optical estimation of lactate is possible. Unlike many existing methods, the proposed method does not impose additional locality constraints on the spectral features and therefore helps provide a much more granular interpretation of wavelength importance
Recommended from our members
The efficacy of support vector machines in modelling deviations from the Beer-Lambert law for optical measurement of lactate
Lactate is an important biomarker with a significant diagnostic and prognostic ability in relation to life-threatening conditions and diseases such as sepsis, diabetes, cancer, pulmonary and kidney diseases, to name a few. The gold standard method for the measurement of lactate relies on blood sampling, which due to its invasive nature, limits the ability of clinicians in frequent monitoring of patients' lactate levels. Evidence suggests that the optical measurement of lactate holds promise as an alternative to blood sampling. However, achieving this aim requires better understanding of the optical behavior of lactate. The present study investigates the potential deviations of absorbance from the Beer-Lambert law in high concentrations of lactate. To this end, a number of nonlinear models namely support vector machines with quadratic, cubic and quartic kernels and radial basis function kernel are compared with the linear principal component regression and linear support vector machine. Interestingly, it is shown that even in extremely high concentrations of lactate (600 mmol/L) in a phosphate buffer solution, the linear models surpass the performance of the other models
Recommended from our members
Near Infrared Spectrometric Investigations on the behaviour of Lactate
In patients with life-threatening illnesses, the metabolic production and disposal of lactate are impaired, which leads to a build-up of blood lactate. In critical care units, the changes in lactate levels are measured through intermittent, invasive, blood sampling and in vitro assay. Continuous monitoring is lacking, yet such monitoring could allow early assessment of severity and prognosis to guide therapy. Currently, there is no routine means to measure lactate levels continuously, particularly non-invasively. The motivation of this study was to understand the interaction of lactate with light in the Near Infra Red (NIR) region of the electromagnetic spectrum. This was to create an opportunity to explore the possibility of a non-invasive sensing technology to monitor lactate continuously.
In vitro studies were performed using solution samples with varying concentration levels of sodium lactate in isotonic Phosphate Buffer Solution (PBS) at constant pH (7.4). These samples were prepared using stoichiometric solution compositions and spectra for each sample were taken using a state-of-the-art spectrometer in the NIR region. The spectra were then analysed qualitatively by 2D correlation analysis, which identified the regions of interest. Further analysis of these regions using linear regression at four randomly selected wavelengths showed bathochromic shifts, which, moreover, showed systematic variation correlating with lactate concentration
Comparison of a Genetic Algorithm Variable Selection and Interval Partial Least Squares for quantitative analysis of lactate in PBS
Blood lactate is an important biomarker that has been linked to morbidity and mortality of critically ill patients, acute ischemic stroke, septic shock, lung injuries, insulin resistance in diabetic patients, and cancer. Currently, the clinical measurement of blood lactate is done by collecting intermittent blood samples. Therefore, noninvasive, optical measurement of this significant biomarker would lead to a big leap in healthcare. This study, presents a quantitative analysis of the optical properties of lactate. The benefits of wavelength selection for the development of accurate, robust, and interpretable predictive models have been highlighted in the literature. Additionally, there is an obvious, time- and cost-saving benefit to focusing on narrower segments of the electromagnetic spectrum in practical applications. To this end, a dataset consisting of 47 spectra of Na-lactate and Phosphate Buffer Solution (PBS) was produced using a Fourier transform infrared spectrometer, and subsequently, a comparative study of the application of a genetic algorithm-based wavelength selection and two interval selection methods was carried out. The high accuracy of predictions using the developed models underlines the potential for optical measurement of lactate. Moreover, an interesting finding is the emergence of local features in the proposed genetic algorithm, while, unlike the investigated interval selection methods, no explicit constraints on the locality of features was imposed. Finally, the proposed genetic algorithm suggests the formation of α-hydroxy-esters methyl lactate in the solutions while the other investigated methods fail to indicate this
Recommended from our members
Near Infrared and Aquaphotomic analysis of water absorption in lactate containing media
Increased concentrations of lactate levels in blood are often seen in patients with life-threatening cellular hypoperfusion or infections. State-of-the-art techniques used in clinical practice for measuring serum lactate concentrations rely on intermittent blood sampling and do not permit continuous monitoring of this all important parameter in critical care environments.In recent years, Near Infrared (NIR) Spectroscopy has been established as a possible alternative to existing methods that can mitigate these constraints and be used for non-invasive continuous monitoring of lactate. Nevertheless, the dominant absorption of -OH overtone bands of water in the NIR presents a challenge and complicates the accurate detection of other absorbers such as lactate. For this reason, comprehensive analysis of the -OH overtone bands with systematic lactate concentration changes is essential. This paper reports on the analysis of NIR spectra of two aqueous systems of varying concentrations of lactate in saline and whole blood using the principles of Aquaphotomics.The results show distinctive conformational and structural differences in lactate-water binding, which arise due to the molecular interactions of bonds present in respective solvents
Recommended from our members
Comparison of a Genetic Algorithm Variable Selection and Interval Partial Least Squares for quantitative analysis of lactate in PBS
Blood lactate is an important biomarker that has been linked to morbidity and mortality of critically ill patients, acute ischemic stroke, septic shock, lung injuries, insulin resistance in diabetic patients, and cancer. Currently, the clinical measurement of blood lactate is done by collecting intermittent blood samples. Therefore, noninvasive, optical measurement of this significant biomarker would lead to a big leap in healthcare. This study, presents a quantitative analysis of the optical properties of lactate. The benefits of wavelength selection for the development of accurate, robust, and interpretable predictive models have been highlighted in the literature. Additionally, there is an obvious, time- and cost-saving benefit to focusing on narrower segments of the electromagnetic spectrum in practical applications. To this end, a dataset consisting of 47 spectra of Na-lactate and Phosphate Buffer Solution (PBS) was produced using a Fourier transform infrared spectrometer, and subsequently, a comparative study of the application of a genetic algorithm-based wavelength selection and two interval selection methods was carried out. The high accuracy of predictions using the developed models underlines the potential for optical measurement of lactate. Moreover, an interesting finding is the emergence of local features in the proposed genetic algorithm, while, unlike the investigated interval selection methods, no explicit constraints on the locality of features was imposed. Finally, the proposed genetic algorithm suggests the formation of α-hydroxy-esters methyl lactate in the solutions while the other investigated methods fail to indicate this
Identification and Quantitative Determination of Lactate Using Optical Spectroscopy—Towards a Noninvasive Tool for Early Recognition of Sepsis
Uninterrupted monitoring of serum lactate levels is a prerequisite in the critical care of patients prone to sepsis, cardiogenic shock, cardiac arrest, or severe lung disease. Yet there exists no device to continuously measure blood lactate in clinical practice. Optical spectroscopy together with multivariate analysis is proposed as a viable noninvasive tool for estimation of lactate in blood. As an initial step towards this goal, we inspected the plausibility of predicting the concentration of sodium lactate (NaLac) from the UV/visible, near-infrared (NIR), and mid-infrared (MIR) spectra of 37 isotonic phosphate-buffered saline (PBS) samples containing NaLac ranging from 0 to 20 mmol/L. UV/visible (300–800 nm) and NIR (800–2600 nm) spectra of PBS samples were collected using the PerkinElmer Lambda 1050 dual-beam spectrophotometer, while MIR (4000–500 cm−1) spectra were collected using the Spectrum two FTIR spectrometer. Absorption bands in the spectra of all three regions were identified and functional groups were assigned. The concentration of lactate in samples was predicted using the Partial Least-Squares (PLS) regression analysis and leave-one-out cross-validation. The regression analysis showed a correlation coefficient (R2) of 0.926, 0.977, and 0.992 for UV/visible, NIR, and MIR spectra, respectively, between the predicted and reference samples. The RMSECV of UV/visible, NIR, and MIR spectra was 1.59, 0.89, and 0.49 mmol/L, respectively. The results indicate that optical spectroscopy together with multivariate models can achieve a superior technique in assessing lactate concentrations
Recommended from our members
Investigations into the Effects of pH on Quantitative Measurements of Lactate in Biological Media Using ATR-FTIR Spectroscopy
Quantification of lactate/lactic acid in critical care environments is essential as lactate serves as an important biochemical marker for the adequacy of the haemodynamic circulation in shock and of cell respiration at the onset of sepsis/septic shock. Hence, in this study, ATR-FTIR was explored as a potential tool for lactate measurement, as the current techniques depend on sample preparation and fails to provide rapid response. Moreover, the effects of pH on PBS samples (7.4, 7, 6.5 and 6) and change in solution conditions (PBS to whole blood) on spectral features were also investigated. A total 189 spectra from five sets of lactate containing media were obtained. Results suggests that lactate could be measured with more than 90% accuracy in the wavenumber range of 1500-600 cm-1. The findings of this study further suggest that there exist no effects of change in pH or media, when estimating lactate concentration changes in this range of the Mid-IR spectral region
Recommended from our members
An empirical investigation of deviations from the Beer-Lambert law in optical estimation of lactate
The linear relationship between optical absorbance and the concentration of analytes-as postulated by the Beer-Lambert law-is one of the fundamental assumptions that much of the optical spectroscopy literature is explicitly or implicitly based upon. The common use of linear regression models such as principal component regression and partial least squares exemplifies how the linearity assumption is upheld in practical applications. However, the literature also establishes that deviations from the Beer-Lambert law can be expected when (a) the light source is far from monochromatic, (b) the concentrations of analytes are very high and (c) the medium is highly scattering. The lack of a quantitative understanding of when such nonlinearities can become predominant, along with the mainstream use of nonlinear machine learning models in different fields, have given rise to the use of methods such as random forests, support vector regression, and neural networks in spectroscopic applications. This raises the question that, given the small number of samples and the high number of variables in many spectroscopic datasets, are nonlinear effects significant enough to justify the additional model complexity? In the present study, we empirically investigate this question in relation to lactate, an important biomarker. Particularly, to analyze the effects of scattering matrices, three datasets were generated by varying the concentration of lactate in phosphate buffer solution, human serum, and sheep blood. Additionally, the fourth dataset pertained to invivo, transcutaneous spectra obtained from healthy volunteers in an exercise study. Linear and nonlinear models were fitted to each dataset and measures of model performance were compared to attest the assumption of linearity. To isolate the effects of high concentrations, the phosphate buffer solution dataset was augmented with six samples with very high concentrations of lactate between (100-600Â mmol/L). Subsequently, three partly overlapping datasets were extracted with lactate concentrations varying between 0-11, 0-20 and 0-600Â mmol/L. Similarly, the performance of linear and nonlinear models were compared in each dataset. This analysis did not provide any evidence of substantial nonlinearities due high concentrations. However, the results suggest that nonlinearities may be present in scattering media, justifying the use of complex, nonlinear models
Recommended from our members
In-vitro spectrometric analysis of hyperlactatemia and lactic acidosis in buffer relating to sepsis
The normal range for pH in the human body is 7.35-7.45. When pH falls below 7.3, it is considered as severe acidemia. Acidemia, together with increased blood lactate concentrations (hyperlactatemia) constitute a severe threat to life, which is often referred to as lactic acidosis. The feasibility of near infrared transmission/reflectance spectroscopy as a tool to determine lactate concentration levels and pH, independently, has been well established. However, the effects on spectral features arising from simultaneous variations in pH and lactate are not fully understood. Hence, this paper reports on a spectroscopic study of 37 different lactate concentrations that were prepared at three different pH levels (7.4, 7.0 and 6.5). Near infrared spectra were acquired in the range 800-2500 nm, and were later divided into four spectral ranges. Further investigations were carried out on various wavelengths within each spectral range and sample set. Furthermore, partial least squares regression with cross-validation was performed on all data sets. The results showed a clear interdependence and overlapping spectral behavior between blood lactate concentrations and pH. The findings from this study suggest that for an accurate estimation of blood lactate using this technique, the pH of the sample must be previously known
- …